BRUSH AMPLIFIER ADJUSTMENT
AMP-0006
AMP-0021
All amplifiers need adjustment after installation. The adjustment is basically the same for all DC
brush amplifiers. Above are the Glentek amplifiers, these instructions are the same for the AMC
amplifiers.
Safety Notice:
This equipment contains High Voltages; up to 240 DC Volts. Improper use can cause
serious or fatal injury. Only qualified personnel should attempt the installation and start-up procedure.
Disclaimer:
In no event shall ITS Inc. or any of our affiliates be liable for any damages whatsoever, and in
particular ITS Inc. or any of our affiliates shall not be liable for special, indirect, consequential, or incidental
damages, or damages for lost profits, loss of revenue, or loss of use arising out of use of this product, whether such
damages arise in contract, negligence, tort, under statute, in equity, at law, or otherwise.
1
Publication No. D-9812-BRUSH AMP v1.5
February 2012

Advertisement

loading

Summary of Contents for Independent Technologies AMP-0006

  • Page 1 9182 Independence Ave. Chatsworth, California 91311 Toll Free: 1.800.342.3475 BRUSH AMPLIFIER ADJUSTMENT AMP-0006 AMP-0021 All amplifiers need adjustment after installation. The adjustment is basically the same for all DC brush amplifiers. Above are the Glentek amplifiers, these instructions are the same for the AMC amplifiers.
  • Page 2: Current Limit

    AMP-0021 AMP-0006 Some potentiometers adjustments are dependent upon your amplifier model and version. Skip adjustment if you don’t see the Pot on your amplifier because it has a fixed value. Potentiometer Definition: Signal Gain Pot The SIG Pot affects how the amplifier converts the input signal to an RPM value. A low adjustment will cause the machine not to get up to the Rapid Traverse speed and it will generate a MOTOR OVERLOAD fault;...
  • Page 3 DC Amplifier Adjustment Procedure Machine with Scales: Before adjusting the amplifier, verify that scale cable (if applicable) is disconnected from the 1010 axis card of the corresponding axis amplifier to be adjusted. If it is connected (using the glass scale feedback), power down the machine, disconnect the cable, and then power up the machine.
  • Page 4 For Metric Ballscrews the target value is 302. For Inch Ballscrews and Rotary tables the target value is 595. Use the SETP command to check the current Ballscrew Type if you’re not sure about which ballscrew you may have. The goal of the adjustment is to match the other axes so the system is dynamically balanced with all the XYZ axes.

This manual is also suitable for: