MANUAL
IMS-M1000
Modular Sync. System and
NTP Server
9th June 2016
Meinberg Radio Clocks GmbH & Co. KG

Advertisement

Table of Contents
loading

Summary of Contents for Meinberg IMS-M1000

  • Page 1 MANUAL IMS-M1000 Modular Sync. System and NTP Server 9th June 2016 Meinberg Radio Clocks GmbH & Co. KG...
  • Page 3 Front view (Frontansicht) IMS-M1000...
  • Page 4 Rear view (Rückansicht) IMS-M1000...
  • Page 5: Table Of Contents

    Table of Contents 1 Imprint 2 Safety instructions for building-in equipment Additional Safety Hints ......... . . Supply Voltage .
  • Page 6 13.6.17 SCG - Studio Clock Generator ........14 Declaration of Conformity Date: 9th June 2016 IMS-M1000...
  • Page 7: Imprint

    1 Imprint 1 Imprint Meinberg Funkuhren GmbH & Co. KG Lange Wand 9, 31812 Bad Pyrmont - Germany Phone: + 49 (0) 52 81 / 93 09 - 0 Fax: + 49 (0) 52 81 / 93 09 - 30 Internet:http://www.meinberg.de...
  • Page 8: Safety Instructions For Building-In Equipment

    • Assembling and disassembling of the power connector is only allowed if the device is disconnected from power supply (e.g. trough primary side line protection). • All feed lines are sufficiently protected and dimensioned. Fuse: T2.5A Connector Diameter: - 2,5mm / 17AWG - 13AWG Date: 9th June 2016 IMS-M1000...
  • Page 9: Additional Safety Hints

    To ensure safe operation supply mains connected to this decice must be equipped with a fuse and a fault- current circuit breaker according to the applicable national standards for safe operation. The device must be connected to a protective earth with low grounding resistance according to the applicable national rules. IMS-M1000 Date: 9th June 2016...
  • Page 10: Cabling

    Do not carry out any installation or maintenance work on the antenna system or cabling when there is a potential risk of lightning. Surge Voltage Protector Due to extremely high currents associated with lightning no surge protection device can provide absolute safety from the impacts caused by lightning! Date: 9th June 2016 IMS-M1000...
  • Page 11: Replacing The Lithium Battery

    Nut M4 Plain washer Tooth washer Ring or fork lug Tooth washer Nut M4 Nomel washer Nomel washer Flat connector Tooth washer Note: Use a grounding cable with >= 1,5mm Please ensure a correct crimp connection! IMS-M1000 Date: 9th June 2016...
  • Page 12: Quick Start

    NOTE: These settings are related to the first Ethernet connection (ETH0). After this all further settings can be done via network interface, either by using a WEB browser or a Telnet Session. Default user: root Default password: timeserver Date: 9th June 2016 IMS-M1000...
  • Page 13: The Modular System Lantime

    VP100/20/NET that is accessed via network connection. In order to avoid a service interruption several LANTIME NTP servers can be installed in the same network to obtain redundancy. IMS-M1000 Date: 9th June 2016...
  • Page 14: Network Timeserver With Gps Synchronized Time Base

    After the network connection has been established the time server can also be configured and monitored remotely from a workstation via TELNET or FTP. An integrated web server enables access to the LANTIME by using an ordinary web browser. Date: 9th June 2016 IMS-M1000...
  • Page 15: Mounting The Gps Antenna

    [dB]/100m RG58/CU RG213 10.5mm (1)This specifications are made for antenna/converter units produced after January, 2005 The values are typically ones; the exact ones are to find out from the data sheet of the used cable IMS-M1000 Date: 9th June 2016...
  • Page 16: Antenna Assembly With Surge Voltage Protection

    Optional a surge voltage protector for coaxial lines is available. The shield has to be connected to earth as short as possible by using the included mounting bracket. Normally you connect the antenna converter directly with the antenna cable to the system. Date: 9th June 2016 IMS-M1000...
  • Page 17: Antenna Short-Circuit

    In case of an antenna line short-circuit the following message appears in the display: If this message appears the clock has to be disconnected from the mains and the defect eliminated. After that the clock can be powered-up again. The antenna supply voltage must be 15V IMS-M1000 Date: 9th June 2016...
  • Page 18: Booting The Gps180 Receiver

    This mode is called Cold Boot. It takes 12 minutes until the new almanac is complete and the system switches to Warm Boot mode, scanning for other satellites. Date: 9th June 2016 IMS-M1000...
  • Page 19: Booting The Single Board Computer

    The NTPD tries to keep the offset below +-128 ms; if the offset becomes too large, the system time is set with the receiver’s time. Typically values for the offset are +-5 ms after the NTPD has already synchronized. IMS-M1000 Date: 9th June 2016...
  • Page 20: Configuration User Interface

    To set up a HTTP connection the following address is to enter in a web browser: http://198.168.10.10 // LANTIME IP address password: timeserver To set up a Secure HTTP (HTTPS) connection the following address is entered in a web browser: https://198.168.10.10 // LANTIME IP address password: timeserver Date: 9th June 2016 IMS-M1000...
  • Page 21: The Menues In Detail

    (look at „Setup Device Parameter / Check Network Linkup“) is not connected „Alarm“ off: no error at moment red: general error – more information will be shown on display. IMS-M1000 Date: 9th June 2016...
  • Page 22 ->Time Service<- Local Strat. Network Restart NTP System Ref. Time -> Interfaces <- Time Service Global Cfg. ->Network <- Services System Ref. Time >Time Zone < Time Service Restart Menu Network Factory Reset ->System <- Date: 9th June 2016 IMS-M1000...
  • Page 23: The Graphical User Interfaces

    Connect to the web interface by entering the following address into the address field of your web browser: http://198.168.10.10 (You need to replace 198.168.10.10 with the IP address of your LANTIME). Default Login User: root Password: timeserver IMS-M1000 Date: 9th June 2016...
  • Page 24: The Web Interface

    Network information - first interface Receiver status NTP status Last messages By using the navigation on top of the page you can reach a number of configuration menus, which are described in the next chapters. Date: 9th June 2016 IMS-M1000...
  • Page 25: Attachment: Technical Information

    13.2 ACM - Active Cooling Module The Active Cooling Module allows the installation of the M1000 safely within the temperature specification. The ACM is easily field-replaceable and allows for a hot-plug replacement without the need to power down the unit. IMS-M1000 Date: 9th June 2016...
  • Page 26: Available Modules And Connectors

    75 Ohm (Bits) shielded data line 10MHz sine shielded data line DFK-3 Error Relay Signal Inputs: BNC, RJ45 E1/T1, var. Freq. shielded data line 10MHz, PPS, IRIG, PP shielded data line Date: 9th June 2016 IMS-M1000...
  • Page 27: Terminal (Console)

    • between different LANTIMEs • Keypad locking for secure • using the keypad of the LCD • Transfer of log files • Install Software Updates • Upload and download secure certificates • (SSL, SSH) and passwords IMS-M1000 Date: 9th June 2016...
  • Page 28: Ims Module Options

    The IMS system LANTIME M1000 is available in two different versions. A standard version with a single receiver module and in a redundant design, which allows the use of two Meinberg receivers. In this case the configuration of the I/O slots is characterized by the availability of the slots for input signals.
  • Page 29: Power Supply 100-240 V Ac/Dc

    5pin DFK Hotplug: It is possible to remove or install the power supply out of the terminal equipment during operation. Pin Assignment: 1: N 2: not connected 3: GND (Ground) 4: not connected 5: L IMS-M1000 Date: 9th June 2016...
  • Page 30: Power Supply 20-72 V Dc

    Class 1 - regarding EN 60950 Hotplug: It is possible to remove or install the power supply out of the terminal equipment during operation. Pin Assignment: 1: not connected 2: - 3: GND (Ground) 4: + 5: not connected Date: 9th June 2016 IMS-M1000...
  • Page 31: Gps Clock

    Nav. Solved: green: positioning successfully Ant. Fail: red: antenna faulty or not connected Fail: red: time has not synchronized Pin Assignment of the DSUB9 Connectors (male): Pin 2: RxD Pin 3: TxD Pin 5: GND IMS-M1000 Date: 9th June 2016...
  • Page 32: Gln Clock

    Nav Solved green: positioning successfully Ant Fail red: antenna faulty or not connected Fail red: time has not synchronized Pin Assignment of the DSUB9 Connectors (male): Pin 2: RxD Pin 3: TxD Pin 5: GND Date: 9th June 2016 IMS-M1000...
  • Page 33: Rsc Switch Card

    In this operation mode the selection of the reference clock is done by a display menu. A switchover of the reference clock in case of an error does not happen, pulse and frequency outputs and the serial interfaces are always enabled. Deactivation of outputs is possible by a display in the “RSC Cntl” menu. IMS-M1000 Date: 9th June 2016...
  • Page 34 1/2: selected reference clock Menu "Switch Unit -> RSC Cntl" REMOTE: enable/disable Switching between automatic and remote operation OUTPUTS: enabled/disabled Disabling outputs during a free run Selected Clk: Selection of the currently active reference clock Date: 9th June 2016 IMS-M1000...
  • Page 35: Lan-Cpu

    R T N A Cache Memory: 16 KB 2nd Level Cache Flash Disk: 1 GB CONSOLE Network 38400 / 8N1 Connector: 10/100 Base-T with RJ45-Jack State LEDs: Connect, Activity and Speed of the network connection IMS-M1000 Date: 9th June 2016...
  • Page 36: Mri - Standard Reference Input Signals

    LED B: green, if 10 MHz or PPS or both signals are available at the same time Figure right:MRI - standard input signals via BNC female connectors Power Requirements: 5 V +-5%, 50 mA Date: 9th June 2016 IMS-M1000...
  • Page 37: Esi - Telecom Synchronisation References

    LED B green: if Clock and Framed flashing green, if Clock and !Framed flashing yellow, if !Clock and Framed off, if !Clock and !Framed Figure right: ESI - telecom signal inputs via BNC female and RJ45 connectors IMS-M1000 Date: 9th June 2016...
  • Page 38: Lne-Gbe: Network Expansion With Gigabit Support

    I/O slot order by which the modules are inserted. In a factory assembling, LNE modules are sorted in an ascending order starting from left to right (see the corresponding figure above). LAN 0 is therefore always the first network interface of the LAN-CPU. Date: 9th June 2016 IMS-M1000...
  • Page 39: Hps-100: Ptp / Synce / Hardware Ntp Interface

    / 32768 Multicast Hybrid Transactions HPS-100 [512]: up to 512 Clients / 65536 Multicast Hybrid Transactions HPS-100 [1024]: up to 1024 Clients / 131072 Multicast Hybrid Transactions HPS-100 [2048]: up to 2048 Clients / 262144 Multicast Hybrid Transactions IMS-M1000 Date: 9th June 2016...
  • Page 40 - off Passiv Mode off - yellow uncalibrated red - red stopped A detailed configuration guide you will find in the corresponding firmware manual of the system. See chapter "The Web Interface -> Configuration: PTP V2". Date: 9th June 2016 IMS-M1000...
  • Page 41: Tsu V3: Ieee-1588 Time Stamp Unit

    LED A - LED B: Shows the current State of the TSU yellow - yellow Listening green - off Master Mode off - green Slave Mode yellow - off Passiv Mode off - yellow uncalibrated red - red stopped IMS-M1000 Date: 9th June 2016...
  • Page 42: Cpe And Bpe Output Modules (Frontend - Backend)

    BPE) or for autonomously generating a wide range of different signals by using a microprocessor (on a CPE). The front-end makes a selection of the signals available on physical connectors. CPE - Backend BPE - Backend Date: 9th June 2016 IMS-M1000...
  • Page 43 3 and output 4 Figure right: BPE Frontend BPE-1000 Standard outputs - BNC female: PPS, 10MHz, TC DCLS and TC AM BPE 5000 Fiber Optic ST-Connectors PPS, 10MHz, TC DCLS und TC AM IMS-M1000 Date: 9th June 2016...
  • Page 44 4 x BNC female Out 1 - Out 4: TC DCLS BPE-2050 4 x BNC female Out 1 - Out 3: TC DCLS Out 4: TC AM BPE-2080 4 x BNC female Out 1 - Out 4: 2.048kHz Date: 9th June 2016 IMS-M1000...
  • Page 45 Figure: CPE Frontends CPE-1000: 4 config. outputs via BNC female CPE-5000: 4 config. outputs / FO - ST connectors CPE-2500: 3 x prog. Pulses (DFK-2) / 1 x TC AM (BNC) IMS-M1000 Date: 9th June 2016...
  • Page 46 TxD + / RxD + TxD - TxD - / RxD - D-SUB 9 Male TxD + PPO + TxD + / RxD+ PPO + TxD - PPO - TxD - / RxD - PPO - Date: 9th June 2016 IMS-M1000...
  • Page 47: Liu - Line Interface Unit

    Power T1 E1 Power: Init blue during initialisation, green in normal operation mode green selected mode T1 red: output disabled yellow: signal quality unknown green selected mode E1 red: output disabled yellow: signal quality unknown IMS-M1000 Date: 9th June 2016...
  • Page 48 IMS-LIU Telecom Output Signals The board LIU (Line Interface Unit) was designed to convert the GPS-locked standard frequency of a precon- nected Meinberg satellite controlled clock (GPS and GLONASS) into several timing signals that can be used for various synchronization or measurement tasks.
  • Page 49 G703-13, balanced isolation 1544 kHz or 2048 kHz isolation micro controller amplifier amplifier clock outputs G703-13, unbalanced amplifier 1544 kHz or 2048 kHz framer & low pass filter 4.096 MHz line interface amplifier IMS-M1000 Date: 9th June 2016...
  • Page 50 BNC connectors or balanced via RJ45 connectors. Two different line codes used for error correction are known for the transmission of framed signals. The board LIU generates B8ZS- (in T1-mode) or HDB3-coded (in E1-mode) output signals by standard. Date: 9th June 2016 IMS-M1000...
  • Page 51 13 Attachment: Technical Information Pulse templates The following pulse templates are required by ANSI (T1-mode) and CCITT (E1-mode) for output signals in telecom applications. The board LIU meets these recommendations. T1 (T.403): E1 (G.703): IMS-M1000 Date: 9th June 2016...
  • Page 52 Power T1 E1 LIU-A4000 LIU-A0040 LIU-A0004 LIU-A2020 LIU-A2002 LIU_A0202 LIU_A0400 LIU-A1111 BITS (4/0) Clock (4/0) Clock (0/4) BITS (2/0) BITS (2/0) BITS (0/2) BITS (0/4) BITS (1/1) Clock (2/0) Clock (0/2) Clock (0/2) Clock (1/1) Date: 9th June 2016 IMS-M1000...
  • Page 53 OCXO in warm up phase 10MHz reference not available Quality of the reference signal is not sufficient All LEDs green: Normal operation, outputs activated Associated LED red: defect output or short circuit during normal operation IMS-M1000 Date: 9th June 2016...
  • Page 54 RSC switch unit. Error Output: Relay A: Clock 1 Relay B: Clock 2 / PPS Relay C: RSC Switch Unit / 10MHz In redundant mode, the jumper on the REL-1000 are set as follows: Date: 9th June 2016 IMS-M1000...
  • Page 55 Technical Specification ERROR Relays: Switching Voltage: 220 V DC / 250 V AC Switching Load: 60 W /62.5 VA UL/CSA: 0.3 A 125 V AC 0.3 A 110 V DC 30 V DC Response Time: ca.3 ms IMS-M1000 Date: 9th June 2016...
  • Page 56 4 x BNC (2.5V TTL into 50 Ohm) outputs with configureable frequencies Input Signal: 10MHz, sinewave or square pulse Current Consumption: 5 V +- 5%, @400 mA Ambient Temperature: 0 ... 50 C / 32 ... 122 F Humidity: 85% max. Date: 9th June 2016 IMS-M1000...
  • Page 57 In the "IO Configuration" menu each output frequency can be adjusted seperately. In the figure above the following value is set: Frequency Out 3 = Base Frequency * Scale Frequency Out 3 = 44,1 kHz * 1/4 Frequency Out 3 = 11,025 kHz IMS-M1000 Date: 9th June 2016...
  • Page 58 14 Declaration of Conformity Konformitätserklärung Doc ID: LANTIME M1000-2015-06-04 Hersteller Meinberg Funkuhren GmbH & Co. KG Manufacturer Lange Wand 9, D-31812 Bad Pyrmont erklärt in alleiniger Verantwortung, dass das Produkt, declares under its sole responsibility, that the product Produktbezeichnung LANTIME M1000 Product Designation auf das sich diese Erklärung bezieht, mit den folgenden Normen übereinstimmt...