<Storm>
Set Off
If Time 18:00 to 18:30 Then ON
If DoW S-T-T-S Then OFF
And the profiles are defined as:
<RampUp Profile>
Ramp time: 60 minutes
Start intensity: 0
End intensity: 100
<RampDn Profile>
Ramp time: 60 minutes
Start intensity: 100
End intensity: 0
<Weather Profile>
Light maximum intensity: 100
Cloudy light intensity: 50
Cloud duration (MMM): 5
Cloudy time (%): 50
Probability of lightning (%): 50
Lightning intensity (%): 100

ADVANCED PUMP EXAMPLE

The following program assumes that there are two pumps in the Aquarium – one on the right side, and one on
the left side. This example shows how each pump can be controlled independently, and its mode of operation
changed multiple times throughout the day.
The following programs are used for each of the VorTech outlets.
<PumpLeft>
Set Calm
If Time 8:00 to 10:00 Then WaveLeft
If Time 12:00 to 14:00 Then ON
If Time 16:00 to 20:00 Then OFF
If Time 22:00 to 06:00 Then Night
If FeedA 000 Then Off
<PumpRight>
Set Calm
If Time 8:00 to 10:00 Then WaveRight
If Time 12:00 to 14:00 Then OFF
If Time 16:00 to 20:00 Then ON
If Time 22:00 to 06:00 Then Night