CPCI PSB System Subrack 10 U User Manual Product Number: 24579-028 Revision: R1.1, October 30, 2009 Doc-No: 63972-163...
Page 2
Rev. Date updated Change R1.0 November 21, 2007 Initial release R1.1 October 30, 2009 Second CMM slot removed Impressum: Schroff GmbH D-75334 Straubenhardt, Germany The details in this manual have been carefully compiled and checked - supported by certified Quality Management System to EN ISO 9001/2000 The company cannot accept any liability for errors or misprints.
CPCI System Subrack 10 U 24579-028 Table of Contents Safety ......................... 1 Intended Application .................... 1 Safety Instructions ....................2 Safety Symbols used in this document..............2 General Safety Precautions................. 2 References and Architecture Specifications ............3 Product Definition..................... 4 Mechanical Overview...................
Page 4
CPCI System Subrack 10 U 24579-028 www.schroff.biz R1.1, October 30, 2009...
CPCI System Subrack 10 U Safety 24579-028 1 Safety 1.1 Intended Application The CompactPCI (CPCI) system subrack, described in this manual, is intended as a platform for a microcomputer system based on the CompactPCI Standard PICMG 2.0 Rev.3 and PICMG 2.16. The CPCI system subracks are designed for protection class IP 20 and can be used only in the resp.
CPCI System Subrack 10 U Safety 24579-028 1.2 Safety Instructions The intended audience of this User’s Manual is system integrators and hardware/software engineers. 1.3 Safety Symbols used in this document Hazardous voltage! This is the electrical hazard symbol. It indicates that there are dangerous voltages inside the Shelf.
CPCI System Subrack 10 U Safety 24579-028 1.5 References and Architecture Specifications • User Manual CPCI Backplane 23006-610 Order no.: 73972-089 • User Manual CPCI Backplanes Order no.: 73972-101 • User Manual Fan Control Module (FCM) Order no.: 73972-083 • User Manual Power Supply Order no.: 73972-077 •...
CPCI System Subrack 10 U Product Definition 24579-028 2 Product Definition The Schroff CPCI system subrack consists of: • A shielded 19“ subrack with front assembly area for 6 U front boards according to CompactPCI Standard PICMG 2.0 Rev.3 and PICMG 2.16 •...
CPCI System Subrack 10 U Product Definition 24579-028 2.1 Mechanical Overview Figure 1: Mechanical Overview 10006813 DC Switch Power Supply #2 Power Supply #1 Chassis Monitoring Module (CMM) (optional) Front card cage with guide rails Power Supply #4 (optional) Power Supply #3 (optional) Front panel 3 U / 1 HP Drawer with Fans Bottom-hinged front panel,...
CPCI System Subrack 10 U Product Definition 24579-028 2.3 CPCI PSB Backplane Figure 2: Backplane 12307811 The 6 U Backplane provides: • 2 Fabric Slots placed left to the Node Slots including optional Link between both • 14 Node Slots •...
CPCI System Subrack 10 U Product Definition 24579-028 2.4 Power Supply Hazardous voltage! Parts of the power supply may be exposed with hazardous voltage. Always remove mains/line connector before carry out any assembly work. Caution! Your system has not been provided with a AC power cable. Purchase a AC power cable that is approved for use in your country.
CPCI System Subrack 10 U Product Definition 24579-028 2.4.1 Grounding Caution! The unit is designed in accordance with protection class 1! It must therefore be operated with protective earth/GND connection. Use only a three conductor AC power cable with a protective earth conductor that meets the IEC safety standards! The subrack provides two M5 studs to connect a double-lug ground terminal cable.
CPCI System Subrack 10 U Product Definition 24579-028 2.4.2 Power Supply Figure 4: Power Supply 10006814 Table 1: Data AC Power Supply Input voltage nominal 100 - 240 VAC Mains Frequency 50 / 60 Hz Output (max.) 250 W Output voltages 12.0 -12.0 Ripple...
Page 14
CPCI System Subrack 10 U Product Definition 24579-028 Figure 5: Block Diagram 12307813 www.schroff.biz R1.1, October 30, 2009...
CPCI System Subrack 10 U Product Definition 24579-028 2.5 Thermals The front boards are cooled by forced air convection through 3 speed controlled 24 VDC axial fans (290 m³/h (170 cfm) each. The fans are assembled on a drawer behind the perforated front panel at the bottom of the system.
CPCI System Subrack 10 U Product Definition 24579-028 2.6 Fan Control Module (FCM) The Fan Control Module (FCM): • Monitors and controls up to four fans • Monitors the signals from up to four temperature sensors • Speed up the fans in case of a failure of one fan •...
CPCI System Subrack 10 U Product Definition 24579-028 2.7 Chassis Monitoring Module (CMM) -optional- The Chassis Monitoring Module (CMM) • monitors the three VME voltages • can monitor two additional voltages with a range of ±24 V • can monitor up to seven NTC temperature sensors •...
CPCI System Subrack 10 U Installation 24579-028 3 Installation 3.1 Unpacking Caution! When opening the shipping carton, use caution to avoid damaging the system. Consider the following when unpacking and storing the system: • Leave the system packed until it is needed for immediate installation. •...
CPCI System Subrack 10 U Installation 24579-028 3.2 Rack-Mounting Warning! Do NOT move the a full equipped system by yourself. Due to the weight at least two persons are needed to accomplish this task Warning! Do NOT stack the system on top of any other equipment. If the system falls, it can cause severe bodily injury and damage the equipment.
CPCI System Subrack 10 U Installation 24579-028 3.3 Initial Operation Warning! Voltages over 60 VDC can be present in this equipment. This equipment is intended to be accessed, to be installed and maintained by qualified and trained service personnel only. This equipment is designed in accordance with protection class 1! It must therefore be operated only with protective GND/earth connection! Before starting the system with CPCI boards the following tests have to be done:...
CPCI System Subrack 10 U Service 24579-028 4 Service 4.1 Technical support and Return for Service Assistance For all product returns and support issues, please contact your Schroff sales distributor or www.schroff.biz. We recommend that you save the packing material. Shipping without the original packing material might void the warranty.
CPCI System Subrack 10 U Service 24579-028 4.3 Scope of delivery Quantity Description 19" subrack, shielded. (front handles: RAL 7016; 19"-brackets, top and base covers: Al ( CPCI PSB Backplane 6U 14 Node Slots, 2 Fabric Slots. Fabric Slots placed left to the Node Slots including optional Link between both 4 PSU Slots acc.
CPCI System Subrack 10 U Technical Data 24579-028 5 Technical Data Table 2: Technical Data Dimensions Height 443.70 mm (10 U) Width 482.60 mm (19“) Depth 276.75 mm Depth with handles 333.20 mm Weight 18 Kg Power supply Input voltage 100 VAC to 240 VAC Mains frequency 50 / 60 Hz...
Page 24
CPCI System Subrack 10 U Technical Data 24579-028 www.schroff.biz R1.1, October 30, 2009...