1 Introduction
The hybird series inverters (hybrid) of ReneSola are bidirectional which apply to PV system with battery to store energy.
Energy produced by the PV system is used to optimize self-consumption; excess energy is used to charge the batteries, and then fed
into the public grid when the PV energy is adequate,
When PV energy output is insufficient to support connected loads, the system automatically get energy from the batteries if battery
capacity is abundant. If the battery capacity is insufficient to meet own consumption requirements, electricity will be drawn from the
public grid.
The series inverter of ReneSola is design for both indoor and outdoor use.
Figure 1-1 Basic hybrid PV system overview

2 Important Safety Warning

Before using the inverter, please read all instructions and cautionary markings on the unit and this manual. Store the manual where
it can be accessed easily.
The series inverter of ReneSola strictly conforms to related safety rules in design and test.
Safety regulations relevant to the location shall be followed during installation, operation and maintenance.
Improper operation may have a risk of electric shock or damage to equipment and property.
2.1 Symbols
Caution!
Failure to observe a warning indicated in
this manual may result in injury.
Danger of high voltage and electric shock!
Danger of hot surface!
01
Components of the product can be recycled.
This side up; the package must always be
transported, handled and stored in such a way
that the arrows always point upwards.
No more than six (6) identical packages may
be stacked on each other.
Product should not be disposed as
household waste.
CE Mark
Signals danger due to electrical shock and indicates the time (5 minutes) to allow after the
inverter has been turned off and disconnected to ensure safety in any installation operation.
2.2 Safety
● Installation, maintenance and connection of inverters must be performed by qualified personnel, in compliance with local electrical
standards, wiring rules and the requirements of local power authorities and/or companies.
● To avoid electric shock, DC input and AC output of the inverter must be terminated at least 5 minutes before performing any
installation or maintenance.
● The temperature of some parts of the inverter may exceed 60℃ during operation. To avoid being burnt, do not touch the inverter
during operation. Let it cool before touching it.
● Ensure children are kept away from inverters.
● Do not open the front cover of the inverter. Apart from performing work at the wiring terminal (as instructed in this manual),
touching or changing components without authorization may cause injury to people, damage to inverters and annulment of the
warranty.
● Static electricity may damage electronic components. Appropriate method must be adopted to prevent such damage to the
inverter; otherwise the inverter may be damaged and the warranty annulled.
● Ensure the output voltage of the proposed PV array is lower than the maximum rated input voltage of the inverter; otherwise the
inverter may be damaged and the warranty annulled.
● When exposed to sunlight, the PV array generates dangerous high DC voltage. Please operate according to our instructions, or it
will result in danger to life.
● PV modules should have an IEC61730 class A rating.
● If the equipment is used in a manner not specified by the manufacturer, the protection provided by the equipment may be
impaired.
● Completely isolate the inverter should :Switch off the DC switch, disconnect the PV terminal, disconnect the battery terminal,
and disconnect the AC terminal.
● Completely isolate the inverter before maintaining. Not to enter other areas of the inverter when maintaining!
● Prohibit to insert or pull the AC and DC terminals when the inverter is running.
The package/product should be handled
carefully and never be tipped over or slung.
Keep dry; the package/product must be
protected from excessive humidity and must be
stored under cover.
02

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Replus 5048ME and is the answer not in the manual?

Questions and answers

Summary of Contents for ReneSola Replus 5048ME

  • Page 1: Important Safety Warning

    1 Introduction The package/product should be handled The hybird series inverters (hybrid) of ReneSola are bidirectional which apply to PV system with battery to store energy. Product should not be disposed as carefully and never be tipped over or slung.
  • Page 2: Installation

    3 Installation 3.3 Selecting The Mounting Location 3.1 Packing List Mounting location should be selected based on the following aspects: ● The installation method and mounting location must be suitable for the inverter's weight and dimensions. Before installation, please inspect the unit. Be sure that nothing inside the package is damaged. You should have received the ●...
  • Page 3: Electrical Connection

    Please follow below steps to implement AC connection: 3.4 Mounting (1) Check the grid voltage and frequency at the connection point of the inverter. It should meet ReneSola product Spec. Remember that this inverter is heavy! Please be carefully when lifting out from the package.
  • Page 4 48V. 2.5~4mm Please follow below steps to implement battery connection: (1) Check the nominal voltage of batteries. The nominal output voltage should meet ReneSola product Spec. 2.5~4mm (2) Disconnect DC breaker between inverter and battery. Negative plug (3) Disconnect screw cap from insulator.
  • Page 5 - ---- red cable black cable + ---- Cable Waterproof ring RS-485 cover Crystal head Screw cap Insulator Cable core section after crimp Positive Negative Color Function terminal terminal Orange/white RESERVED RESERVED Orange RX RS485B Green white RESERVED Blue Figure 4 Figure 4 Blue white RESERVED...
  • Page 6 For the connection method of three phases EzMeter refer to Figure 4.5-2. Color Function Orange white RESERVED Connection Illustration of Three Phase System(optional) Orange RESERVED Green white RX RS485B Blue RESERVED Color Function Blue white RESERVED Orange/white RESERVED Green RX_RS485A Brown white Orange RESERVED...
  • Page 7: Led Lights Illustration

    Open USB cover If this is your first time to install ReneSola Hybrid Inverter, please first connect the battery and solar panels to the inverter and keep the inverter off-grid, then you can set the inverter in “Setting” menu through Ezmanage with the following steps. After finishing the setting, connect to grid, Then the inverter starts to work.
  • Page 8 Check grid parameters Battery Management Grid (If you have already install a ReneSola EzMeter, you can skip to next step, because ReneSola Hybrid Inverter will automatically control the Battery charging and discharging based on your demand.) Check load parameters Battery Setting...
  • Page 9: Work Modes

    7. Work Modes 6.4 Historical Data Display Hybrid series inverters have the following main work modes based on different conditions: Solar Yield Mode1: Please ensure that the monitoring device has been connected with the Internet and solar Energy produced by the PV system is preferred for local station has been successfully created.
  • Page 10: Error Messages

    8 Error Messages 9 Technical Parameters An error message will be displayed on the APP if a fault occurs. Model Replus 5048ME Replus 3648ME Table 8-1 is the Description of Error Message Solar Error message Description Max. DC power(W) 5400...
  • Page 11 Note Model Replus 5048ME Replus 3648ME Overvoltage category definition Protection Category I : applies to equipment connected to a circuit where measures have been taken to reduce transient overvoltage to a Integrated Residual current monitoring unit low level. Integrated Anti-islanding protection Category II : applies to equipment not permanently connected to the installation.