Heatrae Sadia Handy 3 NT Fitting Instructions Manual
Heatrae Sadia Handy 3 NT Fitting Instructions Manual

Heatrae Sadia Handy 3 NT Fitting Instructions Manual

Handy no touch electric handwash

Advertisement

Quick Links

Handy No Touch Electric Handwash
Fitting Instructions
Important
Please read & understand all these instructions
before commencing installation.
Please leave this manual with the customer for future
reference

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Handy 3 NT and is the answer not in the manual?

Questions and answers

Summary of Contents for Heatrae Sadia Handy 3 NT

  • Page 1 Handy No Touch Electric Handwash Fitting Instructions Important Please read & understand all these instructions before commencing installation. Please leave this manual with the customer for future reference...
  • Page 2: Table Of Contents

    Contents 1. Introduction ....................3 1.1 General ....................3 1.2 Symbols used ..................3 1.3 Abbreviations ..................3 1.4 Liabilities .....................3 2. Safety ......................4 2.1 General safety warnings ..............4 2.2 Recommendations ................4 2.3 Specific safety instructions ..............4 3. Technical specifications ................5 3.1 Technical data ..................5 3.2 Dimensions and connections ..............5 3.3 Electrical diagram(s) ................6 4.
  • Page 3: Introduction

    Our liability as the manufacturer may not be invoked 1. Introduction in the following cases: Failure to abide by the instructions on using the 1.1 General product. Faulty or insufficient maintenance of the The following instructions are offered as a guide to product.
  • Page 4: Safety

    2.2 Recommendations 2. Safety WARNING 2.1 General safety warnings The plumbing installation must comply with Water Regulations. WARNING The supply pipe must be flushed to clear ISOLATE electrical water debris before connecting to the product. supplies before removing the cover. DO NOT solder pipes or fittings within ISOLATE electrical...
  • Page 5: Technical Specifications

    3.1kW - Handwash - 95 020 115 Supplier’s name or trade mark Heatrae Sadia Supplier’s model identifier Handy 3 NT The declared load profile The water heating energy efficiency class of the model The water heating energy efficiency in % 38.6...
  • Page 6: Electrical Diagram(S)

    3.3 Electrical diagram(s) Nominal Power Rating Model 240V 230V Minimum cable size 3.1kW 3.1kW 2.9kW 1.5mm 12.9 amp 12.4 amp Materials Backplate and cover assembly - ABS Element(s) - Copper sheathed rod type. Red or brown to 'L' Dimensions Green & yellow to Height - 235mm Blue or black to 'N' Cable clamp...
  • Page 7: Description Of The Product

    4.2 Operation principle 4. Description of the product The product is used to provide the user with hot water for hand washing. 4.1 General description By activating the sensor the water flows through the This product is manufactured to British and product which then switches the element on to heat European Standard.
  • Page 8: Before Installation

    If the product is operated outside of the stated 5. Before installation pressure parameters it may not be possible to achieve optimum performance from the product throughout the year. 5.1 Installation regulations WARNING WARNING The product must be earthed Installation of the product must be IMPORTANT - INSTALLATION carried out by a qualified engineer in...
  • Page 9: Choice Of Location

    5.3 Choice of location Double pole isolating switch: pull cord or wall mounted in accordance with IEE regulations The product must be mounted on a flat surface, which covers the full width and length of the backplate. It is important that the wall surface is flat otherwise difficulty may be encountered when fitting the cover.
  • Page 10: Fitting Instructions

    A clearance of at least 130mm above and below the product should be allowed for access to the cover screws. Cable entry can be from the rear (preferred) or from the bottom. The backplate has cut-out positions to suit the size of the cable. When opting for bottom entry make the cut- out to suit the cable before fitting 'O' rings the backplate to the wall - see figure 8 below.
  • Page 11: Electrical Connections

    Assemble the installation before making any soldered joints to ensure that the pipe is the correct length. DO NOT use jointing compounds on any pipe fittings for the installation. close CAUTION Remove the product before soldering the connections. It is essential to flush the pipe in order to clear debris, particles of solder and swarf - see figure 12 below.
  • Page 12: Commissioning

    6.4 Fitting cover 7. Commissioning Fit outlet spout if required - see figure 10 p10. 7.1 General Check that the flow control valve is fully closed by turning the gear fully anti-clockwise. NOTE: The first operation of the product is intended to ensure the heater unit contains water before the Place the cover onto the back plate.
  • Page 13: Maintenance

     9. Maintenance I T IS MOST IMPORTANT TO KEEP THE SPRAYPLATE CLEAN IN ORDER TO MAINTAIN THE PERFORMANCE 9.1 General OF THE HANDWASH. The hardness It is recommended that the product casing be of the water will determine the cleaned using a soft cloth and that the use of abrasive frequency of cleaning.
  • Page 14: Troubleshooting

    Environmental information 10. Troubleshooting Handwash products are manufactured from many recyclable materials. In the unlikely event of a problem, consult the trouble- shooting chart below. WEEE Declaration If you are unable to remedy the problem, contact Disposal of Waste Equipment by Users in Private your installer in the first instance.
  • Page 15: Spare Parts

    This product is covered against faulty materials and manufacture for a period of two years from the date The policy of Heatrae Sadia is one of continuous of purchase provided that: product development and, as such, we reserve the right to change specifications without notice.
  • Page 16 Parts Center OUR NATIONWIDE NETWORK OF CUSTOMER SUPPORT ENGINEERS Tel: 0344 292 7057 Heatrae Sadia has its very own dedicated nationwide network of highly trained www.partscenter.co.uk customer support engineers so you can have peace of mind that we’re always here to help.