CONTENTS
1
DESCRIPTION OF THE BOILER . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 37
2
INSTALLATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 38
3
CHARACTERISTICS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 43
4
USE AND MAINTENANCE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 44
FONDERIE SIME S.p.A. of Via Garbo 27 - Legnago (VR) - Italy declares that its hot water boilers, which bear the CE mark under
Gas Directive 90/396/CEE and are fitted with a safety thermostat calibrated to a maximum of 110°C, are not subject to appli-
cation of PED Directive 97/23/CEE as they meet the requirements of article 1 paragraph 3.6 of the Directive.
When carrying out commissioning of the boiler, you are highly recommended to perform the following checks:
- Make sure that there are no liquids or inflammable materials in the immediate vicinity of the boiler.
- Make sure that the electrical connections have been made correctly and that the earth wire is connected to a good
earthing system.
- Open the gas cock and check the soundness of the connections, including that of the burner.
- Make sure that the boiler is set for operation for the type of gas supplied.
- Check that the flue pipe for the outlet of the products of the combustion is unobstructed and/or has been properly
installed.
- Make sure that any shutoff valves are open.
- Make sure that the system is charged with water and is thoroughly vented.
- Check that the circulating pump is not locked.
- Purge the system, bleeding off the air present in the gas pipe by operating the pressure relief valve on the gas valve
inlet.

INSTALLER INSTRUCTIONS

IMPORTANT

Advertisement

loading
Need help?

Need help?

Do you have a question about the RX 26 BF and is the answer not in the manual?

Questions and answers

Summary of Contents for Fonderie SIME RX 26 BF

  • Page 1: Installer Instructions

    USE AND MAINTENANCE ................page 44 FONDERIE SIME S.p.A. of Via Garbo 27 - Legnago (VR) - Italy declares that its hot water boilers, which bear the CE mark under Gas Directive 90/396/CEE and are fitted with a safety thermostat calibrated to a maximum of 110°C, are not subject to appli-...
  • Page 2: Description Of The Boiler

    90/396/CEE, 89/336/CEE, propane gas (G31). 92/42/CEE, 73/23/CEE and t he The “RX 26 BF” boilers are the ideal solu- europen specification EN 483. The instructions given in this manual are tion for heating small and medium houses. These appliances can be fired by natural...
  • Page 3 BOILER ROOM if the safety valve goes into action. When sizing gas piping, from the meter to Models “RX 26 BF”, with a hermetically the boiler, take into account both the volume An adhesive data plate is sticked inside the...
  • Page 4: Installation

    2.2. 1 Filter on the gas pipe TYPE OF INSTALLATIONS The gas valve is supplied ex factory with an C12 Wall outlet and intake exposed to the same wind conditions. inlet filter, which, however, is not adequate C32 Roof outlet and intake exposed to the same wind conditions. to entrap all the impurities in the gas or in C42 Outlet and intake in common separated flues, but exposed to the same gas main pipes.
  • Page 5 pipe insulator, with a density of 50 kg/m TABLE 1 Accessories ø 80 Load loss (mm H The maximum overall length of the intake Intake Outlet Roof out. Intake and exhaust ducts depends on the head 90° elbow MF 0,30 0,50 –...
  • Page 6 min. 700 LIST OF ACCESSORIES THAT ALLOW THE CONFIGURATIONS INDICATED ARE SUPPLIED ON REQUEST: – Separate flue kit code 8089905 – 90° elbow MF code 8077404 – 90° insulated elbow MF code 8077408 – Extension L. 1000 code 8077303 – Insulated extension L. 1000 code 8077306 –...
  • Page 7 2. 1 0 ELECTRICAL The power supply must be single-phase NOTE: Device must be connected to an WIRING 230V - 50 Hz through a main switch pro- efficient eathing system. SIME cannot be tected by a fuse with a distance of at least held liable for damage to people or things If you must replace the electric power 3 mm between contacts.
  • Page 8: Characteristics

    CHARACTERISTICS 3. 1 ELECTRONIC CONTROL BOX The boiler is supplied with HONEYWELL 1 Burner S4565C electronic control box. 2 Detection electrode Ignition and flame detection is controlled by 3 Ignition electrode an electrode located on the burner, which guarantees maximum safety with interven- tion times, for accidental switching off or gas failure within one second (fig.
  • Page 9: Use And Maintenance

    USE AND MAINTENANCE 4. 1 C.H. OUTPUT REGULATION When the boiler is fuelled with natural gas (G20), it is possible to change the maxi- mum pressure value according to the dia- gram shown in fig. 13 in order to adjust 1 Modulator C.H.
  • Page 10 winter. – The room stat has been regulated too PRESSIONE UGELLO mbar NOZZLE PRESSURE mbar low or is faulty and needs to be replaced. – The electrical connections of the room stat have not been carried out properly. – The circulation pump of the system is stopped, release it.
  • Page 11 USER’S INSTRUCTIONS WARNING – Turn off the appliance when default and/or improper operation occurs, do not try to repair it on your own. Contact the local Authorised Customer Service. – Installation of the boiler or any other service or maintenance operation must be carried out only by qualified personnel. It is absolutely forbidden to tamper the device that has been sealed by the manufacturer.