5. Picture Frame Setting (Standard Picture Frame)
In the "CAMERA Adjustment 4", set the picture frame so as to
attain the positions shown in the following figure when shooting
the 9 colors chart.
Check on the oscilloscope
Measurement Point: Video terminal of USB, A/V, DC IN cable for
1. Horizontal period
A
2. Vertical period
B
C =
3
Check on the monitor TV or the LCD screen
C14: Filter for AWB 5800K adjustment
A
Effective picture frame
DSC-T20/T25_ADJ
multi-use terminal (75 Ω terminated)
A = B
B
A
Fig. 6-1-23
B
C
V
Fig. 6-1-24
B
A = B
C =
3
B
A
Green
Yellow
W14
Cyan
White
Red
C14
Blue
Magenta
A
2
Transparent window
Fig. 6-1-25
6. CAMERA Adjustment 4
[Automatic Adjustment Program execution items and
sequence]
1. Data Setting during Camera Adj.
2. Picture Frame Setting
3. F No. Compensation
4. Measure Gain, LV Adj.
5. Mechanical Shutter Adj.
6. AWB 3200K-5800K Standard Data Input
7. AWB 3200K-5800K Check
8. Color Reproduction Adj. & Check
9. CCD Linearity Check
10. CCD White Defect Compensation Check
11. CCD Black Defect Compensation Check
12. Release of Data Setting during Camera Adj.
[Adjusting method]
1) Click the [Start] button of the CAMERA Adjustment 4.
2) The Automatic Adjustment Program executes the "1. Data Set-
ting during Camera Adj.".
3) Upon successful completion of "1. Data Setting during Cam-
era Adj.", "2. Picture Frame Setting" is executed. The follow-
ing message is displayed, and then referring to Fig. 6-1-23 to
Fig. 6-1-25, set the subject and click the [OK] button.
C
After that, the next message is displayed. Then, change the chart
in accordance with the message.
C
B
C
6-27