Epsolar SPP-01 User Manual

Super parameter programmer

Advertisement

Quick Links

Super Parameter Programmer
SPP-01
Dear user:
Thank you very much for selecting our product!
This manual offers important information and suggestions about use and
troubleshooting, etc. Please read this manual carefully before using the
product.
Warranty: The product is warranted to be free from defects for a period of
two years from the date of shipment to the original end user.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SPP-01 and is the answer not in the manual?

Questions and answers

Summary of Contents for Epsolar SPP-01

  • Page 1 Super Parameter Programmer SPP-01 Dear user: Thank you very much for selecting our product! This manual offers important information and suggestions about use and troubleshooting, etc. Please read this manual carefully before using the product. Warranty: The product is warranted to be free from defects for a period of...
  • Page 2: Table Of Contents

    4 Software Operation ............7 4.1 Software Operating Environment........7 4.2 Software Installation and Uninstalling ......7 4.3 Software Operating Instructions ........7 5 Specification ..............22 5.1 Hardware Configuration ..........22 5.2 SPP-01 Parameter............22 6 SPP-01 Overall Dimension ..........23...
  • Page 3: Important Safety Information

     Do not disassemble or attempt to repair it. 2 General Information 2.1 Product Characteristic Super parameter programmer (SPP-01) is the simple, efficient and practical accessory for parameter configuration with the easy one button operation. Due to the new standard communication protocol , it applies to stand-alone or multi-parallel products.
  • Page 4: Main Functions

    SPP-01 with easy one button.  Data transparent transmission function. SPP-01 can be used as the communication converter to connect the device and Solar Station Monitor, a P C software, to establish remote monitoring. 2.3 Recommendation...
  • Page 5: Features

    3 Features 3.1 Features Description Operation Remarks Communication converter mode K1(Toggle P arameter configuration mode switch1) Line Wire communication mode K2(Toggle switch 2) IrDA Reserved Power on K3(Toggle Power off switch 3) P ress the key to enter configuration K4 (Water proof P ress the button mode (the indicator led is on), click it again to update the configuration.
  • Page 6 successfully. with one short beep. Communication The indicator led flashes twice error with two short beeps. The model is not matched or the The indicator led flashes triple irrational with three short beeps. configuration The indicator light flashes for Test several times with one long beep.
  • Page 7: Power Supply And Startup

    RTC Battery Battery compartment USB interface Description Operating Remarks Connect the controller with the Update device RJ11 interface CC-TTL-TTL-150U communication configure cable Connect the controller with the Update device RJ45 interface CC-RS485- RS485-150U configure communication cable Connect to the PC with the Update SPP01 USB interface CC-USB-USB-150U communication...
  • Page 8 2. Get power via exclusive data cable from the device. 3. Get power from 3 batteries (size AAA). Starting SPP -01: The SPP-01 is powered on by toggling K3 switch to “ ON” Operating status Phenomena Normal startup The green light flashes once with one beep.
  • Page 9: Software Operation

    4.3 S oftware Operating Instructions  Get serial port number for SPP-01 1. Connect the device: Connect SPP-01 to the P C with the Micro-USB cable and turn K3 switch to “ ON” position. The SPP-01 starts normally with indicator led flashing once and a short beep.
  • Page 10 2. Install SPP-01 serial port driver: Open directory “ SPP USB Driver” and run “ Setup.bat” file to install the driver. 3. Right click “ My computer > Property > Hardware > Device manager” to pop up a device manager window, seeing the figure below: Note: The serial port number selected in the figure above is the serial port number of SPP -01 (COM8).
  • Page 11 SPP-01. The software will automatically open the port after selected serial port of SPP-01(the button caption will change from “ open port” to “ close port”) The following dialog box will be popped up automatically by clicking “ SELECT” tag:...
  • Page 12 “ ”). After configuration, click button to load configuration into SPP-01 device (a corresponding dialog box will be popped up to prompt whether loaded successfully or not). Reading parameter data If the configuration has been loaded to the SPP-0, click button to upload the configuration in SPP -01 to P C, and refresh the corresponding parameter configuration in “...
  • Page 13 button to save the configuration as a text file with extension of .TXT. If it is required to import configurat ion backed up previously, click button to load corresponding TXT file to upload the configuration.  Control Parameter Battery type Battery type Notes Sealed (default)
  • Page 14 Charging Mode Charging mode Notes Voltage Voltage control charging (default) compensation Set the charge and discharge SOC target values for battery charge and discharge control Other Control P arameter Parameters Default Range Battery Ah 200Ah 1~9999Ah Temperature compensation -3mV/º C/2V -9~-0mV coefficient Rated Voltage...
  • Page 15 Boost Charging V oltage 14.2V 14.4V 14.6V 9~17V Float Charging Voltage 13.8V 13.8V 13.8V 9~17V Boost Return V oltage 13.2V 13.2V 13.2V 9~17V Low V oltage Reconnect 12.6V 12.6V 12.6V 9~17V Under V oltage Recover 12.2V 12.2V 12.2V 9~17V Under V oltage Warning 9~17V Low V oltage Disconnect 11.1V...
  • Page 16  Load Configuration Load Mode  Manual (load can be switched by manual button or remote control command) Controller switches on the load output once initialized On by default and keep constant output on condition that the battery is enough electricity and no abnormal situation.
  • Page 17 Controller keep the load output off before, during and after initialized. The load can be switched on o nly when Off by default doing “ Manual On by default” operation and the battery is enough electricity and no abnormal situation . ...
  • Page 18  Light ON+ Timer Working Time 1 Load working period after light control turns ON load (T1) Working Time 2 Load working period before light control turns OFF load (T2) The controller calculated the total length of the night by Night Time self-learning.
  • Page 19  LED Load Configuration  LED Load parameter Parameter Remark LED Rated Current Rated output current. Set up the parameter of the rated current percentage of the LED Rated Current corresponding operating period of the controller; the P ercentage controller will control the LED load output current according to this value.
  • Page 20 When the battery is under this voltage, the output current Battery Under will be half; when the voltage of the battery goes above it, Voltage Control the controller will resume the set current value automatically.  Manual Control(load can be switched by manual button or remote control command) Controller switches on the load output once initialized Manually On By...
  • Page 21 When input voltage of solar module goes above light Light OFF OFF voltage, the solar controller will recognize the Voltage starting voltage and turn off the load after pre-set time delay. The confirmation time for Light signal. During the period, if light signal voltage continues matching Light Delay Time ON/OFF voltage, it will carry out corresponding actions(The time adjustment range:0~99mins.
  • Page 22  Light Control +Time Model 2 Load working period after light control turns ON Work Time1 (T1) load. The running hour of the load after the end of the Work Time2 (T2) work time 1. Load working period before light control turns off Work Time3(T3) load.
  • Page 23 SPP time Display real-time clock of SPP-01. The current P C time data can be directly update to SPP-01 by clicking “ Update” button; click “ Manually” button to edit the values; click “ Read” button to get the time from SPP -01 and display in “ SPP Time” text box.
  • Page 24: Specification

    5 Specification 5.1 Hardware Configuration Items Descriptions Indicator light 1 green LED indicator The real-time clock will not be lost when the RTC clock backup battery is installed. Please replace the batteries when the time of SPP -01 is not correct. From three AAA (7#) batteries;...
  • Page 25: Spp-01 Overall Dimension

    6 SPP-01 Overall Dimension...