● options A description of the connection variants and the pin assignments on the inputs and outputs ● A comprehensive introduction to the configuration of the modules using DEWESoft® ● Detailed technical data: Specifications, etc. ● ...
DEWESoft® and certain parts of the program. The latest version of the DEWESoft® tutorials can be found here: https://download.dewesoft.com/list/manuals-brochures/software-manuals In the S oftware Manuals section click the download link of the DEWESoft X3 tutorials entry. Important ...
IOLITE® EtherCAT® cable (included in the shipment) ● your PC with Windows 10 (older versions like Windows® 7 may also work) ● 2.1. Software installation For optimal working, we recommend that you install the latest version of Dewesoft®. If you already have ...
IOLITE® Illustration 2: Connection of IOLITEs standalone device to PC 2.2.1. DEWESoft® Settings IOLITE® The connected device will show up in the DEWESoft® settings. Click on the Options button at the top ...
TECHNICAL REFERENCE MANUAL IOLITE® Illustration 4: DEWESoft® settings: Devices 2.2.2. Channel Setup IOLITE® In the channel setup you can see a preview of the connected devices on the left side. When you click on a connector in the image the corresponding channel in the Channel setup ...
Manual from the pop-up menu. Illustration 7: Help - Manual When DEWESoft® has started up, you will be in the Measure mode and see the Setup files list. Click on ...
TECHNICAL REFERENCE MANUAL IOLITE® Illustration 8: Setup files 2.3.2. Analogue channel setup In the analogue channel setup screen you can see all channels of your connected IOLITE® systems. Per ...
Hint When switching to Measure mode the data will not be stored automatically. Illustration 11: Measure mode In measure mode you can have several measurement screens (5). DEWESoft® will create 2 default ...
Settings dialogue. Click the Settings button (1) – and then click the Settings Menu item (2). Illustration 13: Open settings dialogue In the Analog tab sheet, DEWESoft USB must be selected in order to user you IOLITE® device (see (1) in ...
TECHNICAL REFERENCE MANUAL IOLITE® Illustration 14: Real measurement mode 2.5. Licensing As soon as you activate your IOLITE® system in the hardware setup, DEWESoft® will be licensed and ...
TECHNICAL REFERENCE MANUAL IOLITE® 3. System Overview IOLITE Data acquisition and real-time control front-end system for industrial applications. All-in-one solution for real-time control and feedback monitoring Voltage Strain / Stress Quarter Bridge ...
● functionality, award-winning DEWESoft X3 software is included. The software comes with lifetime free upgrades and no hidden costs, bringing you intuitive configuration, smart sensors, ...
TECHNICAL REFERENCE MANUAL IOLITE® 3.2. System specifications System IOLITEr IOLITEs Number of slots 12 8 Synchronization 2x SIRIUS® SYNC on L00B4f 2x SIRIUS® SYNC on L00B4f Sync Accuracy below 1 sample to Sirius® below 1 sample to Sirius® Dual EtherCAT®...
TECHNICAL REFERENCE MANUAL IOLITE® 3.3. Enclosure Overview IOLITE can be configured in the 19-inch cabinet compatible chassis or in more rugged SIRIUS-like compatible chassis. 3.3.1.
TECHNICAL REFERENCE MANUAL IOLITE® Illustration 17: Cooling system on the Back panel of IOLITEr 3.3.1.2. IOLITEr: Cabinet Mount Chassis: Dimensions Illustration 18: Technical Drawings of IOLITEr V1.0 24 / 80 ...
Secondary bus (BUS 2) for unbuffered data have IN and OUT connector. Two LEMO 1B 2-pin connectors are used for redundant power supply (PWR IN). Synchronization with DEWESoft USB data acquisition devices or connection to clock master is on ...
TECHNICAL REFERENCE MANUAL IOLITE® Illustration 20: IOLITE-GATE front 3.3.1.3.1.1. IOLITE-GATE: Power in: Pinout For the power supply an unregulated DC voltage between 12 and 48 Volts is required, which is ...
3.3.1.3.1.2. IOLITE-GATE: Sync: Pinout The sync connectors are required when you want to synchronize the data from IOLITE with DEWESoft USB devices for the same measurement. The signal that is transferred over sync cable makes sure that the measurement data of IOLITE and DEWESoft USB devices are perfectly synchronized to each other. ...
Wiring diagram is shown in Illustration 21. Illustration 21: Connection of IOLITEr standalone device to PC List of required cables: Function DEWESoft ORDER CODE Power supply PS-120-L1B2f (default) Ethercat CABLE-UTP-CAT.6-3m (default), CABLE-UTP-CAT.6-1m ...
Illustration 22: Connection of IOLITEr and DEWE-43A device List of required cables: Function DEWESoft ORDER CODE Power supply IOLITEr: PS-120-L1B2f (default) DEWE-43A: PS-60W-12V-5A-L1B2f (default) Ethercat CABLE-UTP-CAT.6-3m (default), CABLE-UTP-CAT.6-1m USB CABLE-USBAmini-USBBS-1.8m (default), CABLE-USBAmini-USBBS-1m Synchronization L00B4m-L00B4m-0.2m (default), L00B4m-L00B4m-0.5m, L00B4m-L00B4m-3m ...
TECHNICAL REFERENCE MANUAL IOLITE® 3.3.2. IOLITEs: Boxed Chassis In addition to 19-inch rack cabinet compatible chassis, IOLITE is also available in standalone aluminium chassis compatible with SIRIUS data acquisition instruments. The chassis provides 8 slots for IOLITE input and output slices to be installed. ...
IOLITE® 3.3.2.3.4. IOLITEs: Boxed Chassis: BUS 1: OUT: Pinout OUT connector of primary EtherCAT bus (BUS 1) is LEMO 1B 8-pin female connector. OUT connector enables power supply for external DEWESoft EtherCAT devices. ...
Illustration 26: Connection of IOLITEs standalone device to PC List of required cables: Function DEWESoft ORDER CODE Power supply PS-120-L1B2f (default) Ethercat L1T8f-RJ45-1M (default), L1T8f-RJ45-3M, L1T8f-RJ45-5M V1.0 38 / 80 ...
Illustration 27: Connection of IOLITEs and KRYPTON® device List of required cables: Function DEWESoft ORDER CODE Power supply PS-120-L1B2f (default) Ethercat IOLITE to PC: L1T8f-RJ45-1M (default), L1T8f-RJ45-3M, L1T8f-RJ45-5M IOLITE to KRYPTON: L1T8m-L1T8f-02M, L1T8m-L1T8f-0.4M, L1T8m-L1T8f-1M, L1T8m-L1T8f-2.5M ...
TECHNICAL REFERENCE MANUAL IOLITE® 3.3.2.6. IOLITEs: Boxed Chassis: Connection of IOLITEs and SIRIUS® device Connect power supply cable SIRIUS (PS-120W-L1B2f). Then connect cable (CABLE-USBAmini-USBBS-1.8m) to the USB port on the back panel of SIRIUS device. Finally connect the ...
Page 41
TECHNICAL REFERENCE MANUAL IOLITE® List of required cables: Function DEWESoft ORDER CODE Power supply SIRIUS: PS-120-L1B2f (default) SIRIUS to IOLITE: L1B2m-L1B2f-0.2m, L1B2m-L1B2f-0.4m, L1B2M-L1B2F-3m Ethercat IOLITE to PC: L1T8f-RJ45-1M (default), L1T8f-RJ45-3M, L1T8f-RJ45-5M USB CABLE-USBAmini-USBBS-1.8m (default), CABLE-USBAmini-USBBS-1m Synchronization L00B4m-L00B4m-0.2m (default), ...
TECHNICAL REFERENCE MANUAL IOLITE® 4.1. DI: Digital Input Module IOLITEi-32xDI module has 32 digital inputs. This is a perfect choice for control applications. IOLITE digital input module includes power out option, where unregulated power supply voltage is ...
TECHNICAL REFERENCE MANUAL IOLITE® 4.1.1. DI: Specifications Digital Input Isolated Input Channels 32 Input low level -1 V ~ +1 V Input high level -48 V ~ -3 V, +3 V ~ +48 V Input high current @5 V UIN <...
TECHNICAL REFERENCE MANUAL IOLITE® 4.1.2. DI: Connector version IOLITEi-32xDI module has four 9-pin terminal block connectors with 2.50mm pitch for digital input. 8 pins on a 9-pin connector bank are used for digital inputs and pin 9 for common GND. ...
TECHNICAL REFERENCE MANUAL IOLITE® 4.1.2.1. DI: Digital Input: Pinout Pin Name Description 1 DI 1 Digital input 1 2 DI 2 Digital input 2 3 DI 3 Digital input 3 4 DI 4 Digital input 4 5 DI 5 ...
IOLITE digital output modules also offer watchdog functionality. Hint Find out more about Watchdog feature in Watchdog User Manual: https://download.dewesoft.com/list/manuals-brochures/software-manuals In the S oftware Manuals section click the download link of the Watchdog User Manual entry. ...
TECHNICAL REFERENCE MANUAL IOLITE® 4.2.1. DO: Specifications Digital Output Isolated Output Channels 32 Compatibility Solid state relay Maximum sink current 0.5 A Maximum switching voltage 50 V Maximum update rate depending on EtherCAT master Isolation voltage peak 1000 V channel to ground, no channel to channel isolation Additional Specifications ...
TECHNICAL REFERENCE MANUAL IOLITE® 4.2.2. DO: Connector version IOLITE-32xDI module has four 9-pin terminal block connectors with 2.50mm pitch for digital input. 8 pins on a 9-pin connector bank are used for digital inputs and pin 9 for common GND. ...
TECHNICAL REFERENCE MANUAL IOLITE® 4.2.2.1. DO: Digital Output: Pinout Pin Name Description 1 DO 1 Digital output 1 2 DO 2 Digital output 2 3 DO 3 Digital output 3 4 DO 4 Digital output 4 5 DO 5 ...
TECHNICAL REFERENCE MANUAL IOLITE® 4.3. RTD: Resistance Temperature Detector Module IOLITE RTD module with 6-pin Lemo 0B input connectors is used for measurements with universal ...
TECHNICAL REFERENCE MANUAL IOLITE® 4.3.1. RTD: Specifications Analog inputs Input types voltage, resistor or universal PTxxx inputs Number of channels 8 ADC Type 24-bit delta-sigma Sampling Rate Simultaneous 100 S/sec Voltage Ranges ±1 V ±100 mV Input Accuracy ±0.02 % of reading ±0.01 % of range ±10 μV ±0.02 % of reading ±0.01 % of range ±10 μV Typical Noise floor @10/100 s/sec ...
TECHNICAL REFERENCE MANUAL IOLITE® 4.4.1. STG: Specifications Analog inputs - Voltage Voltage Full/half/quarter bridge strain Current Input type Potentiometer Number of channels 6 ADC Type 24-bit SAR with anti-aliasing filter Sampling Rate Simultaneous 20 kS/sec per channel (software-selectable) Voltage Ranges ±50 V ±10 V ...
TECHNICAL REFERENCE MANUAL IOLITE® 4.4.2.2. STG: DSUB-9 Connector: Wiring diagram 4.4.2.2.1. STG: Voltage (single-ended) 4.4.2.2.2. STG: Voltage (differential) Important Use only when the sensor is powered by the excitation voltage of the module. ...
TECHNICAL REFERENCE MANUAL IOLITE® 4.5. TH: Thermocouple Module IOLITE TH modules are isolated DAQ devices for temperature measurements using thermocouples. Isolated thermocouple module can acquire data from any kind of thermocouple (K, J, T, R, S, N, E, C, B). It ...
TECHNICAL REFERENCE MANUAL IOLITE® 4.5.1. TH: Specifications Inputs Input type Isolated universal thermocouple and voltage Number of channels 8 ADC Type 24-bit delta-sigma Sampling Rate Simultaneous 100 S/sec Voltage Ranges ±1 V ±100 mV Input Accuracy ±0.02 % of reading ±10 μV ±0.02 % of reading ±10 μV ...
be found in a separate document, which is available for download from our homepage: https://download.dewesoft.com/download-file/accessories-and-sensors-technical-reference-manual.pdf In the H W Manuals section click the download link for the M anual for DEWESoft Accessories and ...
Dewesoft d.o.o. assumes no liability for the customer’s failure to comply with these requirements. All accessories shown in this document are available as an option and will not be shipped as standard ...
Dewesoft sales and service office for service and repair to ensure that safety features are ...
Page 77
TECHNICAL REFERENCE MANUAL IOLITE® noises. the system does not work anymore. the system has been exposed to long storage in adverse environmental. the system has been exposed to heavy shipment strain. Warranty void if damages caused by disregarding this manual.
Dewesoft system can be requested. We retain them for at least one year, after system delivery. 7.3. Support Dewesoft has a team of people ready to assist you if you have any questions or any technical difficulties ...