Force 10 E300 Manual

Ac power supply modules

Advertisement

Installing the E300 AC Power Supply Modules

The E300 Power Supply Module is capable of operating at either 110 VAC or 220 VAC. If the E300 is
connected to a 110 VAC power supply, three power supply modules are required to provide power to the
E300 system, or four power supply modules are required for power supply redundancy.
If the E300 is connected to a 220 VAC power supply, two power supply modules are required to provide
power to the E300 system, three power supply modules are required for power supply redundancy, and
four power supply modules are required for full facility redundancy.
For full facility redundancy, each power supply must be attached to an independent power source with a
dedicated circuit breaker sized in accordance with your local building and electrical safety codes. To
comply with safety agency and emission requirements, a power supply blank cover must be inserted into
any unused power supply slot.
Caution: Before removing and replacing a power supply module, determine if the E300 is in full
facility redundancy or non-redundant power. Operating in non-redundant power will require a
complete system power off when removing and replacing a power supply.

Power Requirements

Nominal Input Voltage
Maximum AC Power Supply Input
Maximum System Power Input

Power Cord Requirements

Each AC power supply is shipped with a Force10-approved AC power cord and only that cord should be
used to connect the AC power supply to the appropriate AC outlet. The power source end of the power
cord must have an appropriately sized plug that complies with your local electrical codes. Conductor size
must also conform to your local electrical codes.
Caution: The power cord is the main power disconnect device; ensure that the socket-outlet is
located/installed near the equipment and is easily accessible.
101-00129-03
100 - 120 VAC Requires a minimum of three Power Supplies Installed
200 - 240 VAC Requires a minimum of two Power Supplies Installed
10 A @ 100 VAC per module
7 A @ 200 VAC per module
4.80 KVA @ 100 VAC
4.60 KVA @ 220 VAC

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the E300 and is the answer not in the manual?

Questions and answers

Summary of Contents for Force 10 E300

  • Page 1: Power Requirements

    Installing the E300 AC Power Supply Modules The E300 Power Supply Module is capable of operating at either 110 VAC or 220 VAC. If the E300 is connected to a 110 VAC power supply, three power supply modules are required to provide power to the E300 system, or four power supply modules are required for power supply redundancy.
  • Page 2 Slot 3 fn00121b Optional Grounding Air Filter Holes The E300 contains four power supply slots in the rear of the chassis (Figure Each AC power supply contains two LEDs: Status and AC. Table 1 describes the LEDs. Table 1 AC Power Supply LEDs Description Green: no fault detected;...
  • Page 3 Toggle the Standby Switch of the power supply to the standby position, Standby position as shown in the image here. Note: If the E300 is already operating, you can insert a new power supply without shutting down the E300. Slide the power supply into any open power supply slot. See Figure 1 for correct orientation.
  • Page 4 After you have verified the power, toggle the Standby switch to the OFF (left) position for all power supplies and remove the unit power cords from the AC outlet. Make sure the AC Power Supply Status and AC LEDs are not lit and continue the E300 installation process.