DOMUSA TEKNIK Domestic D-3 Installation Instructions Manual
DOMUSA TEKNIK Domestic D-3 Installation Instructions Manual

DOMUSA TEKNIK Domestic D-3 Installation Instructions Manual

Oil burner

Advertisement

INSTALLATION AND FUNCTIONING
INSTRUCTIONS
OIL BURNER
DOMESTIC
D-3 / D-4
This instruction manual includes all the details necessary for the proper installation and use of the burner.
We thank you for having chosen a DOMUSA TEKNIK burner

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Domestic D-3 and is the answer not in the manual?

Questions and answers

Summary of Contents for DOMUSA TEKNIK Domestic D-3

  • Page 1 INSTALLATION AND FUNCTIONING INSTRUCTIONS OIL BURNER DOMESTIC D-3 / D-4 This instruction manual includes all the details necessary for the proper installation and use of the burner. We thank you for having chosen a DOMUSA TEKNIK burner...
  • Page 3: Oil Installation

    - 1 - 1.- MOUNTING Fix the burner support to the boiler. Fix the burner to the support. This allows a correct inclination of the flame tube towards the combustion chamber. Mount the oil aspiration and return tubes, including the oil-filter in the aspiration. 2.- OIL INSTALLATION "Domestic"...
  • Page 4: Dimensions Table

    - 2 - 6.- DIMENSIONS DIMENSIONS TABLE DIMENSION 292 265 140 152 215 75 98 290 ø80 205 100 100 ø90 (mm) F: Domestic D-3. F': Domestic D-4.
  • Page 5 - 3 - 7.- PRIMARY COMBUSTION AIR ADJUSTMENT To adjust the primary combustion air, turn the screw as shown on the drawing by means of a 6 mm. Allen wrench. To increase the airflow, turn it to the right and to decrease it, turn it to the left. 8.- COMBUSTION LINE ADJUSTMENT To adjust the combustion line, unscrew the combustion line blocking screw "BL".
  • Page 6: Oil Pressure Adjustment

    - 4 - 10.- OIL PRESSURE ADJUSTMENT To adjust the pressure of the oil pump, turn the screw (1) to the right in order to increase it and to the left in order to decrease it. SUNTEC - MOD. AS47C DANFOSS - MOD.
  • Page 7: Technical Data

    - 5 - 12.- TECHNICAL DATA MODEL Min. heat outlet Kg/h Max. heat outlet Kg/h 4,65 Min. heat outlet kW min. 17,7 27,2 35,5 55,2 Max. heat outlet kW max. 110 W Motor power at 2800 r.p.m. Mono-stage Type of control 220/230 V - 50 Hz Electrical power 12,5...
  • Page 8: Electrical Diagrams

    - 6 - 15.- ELECTRICAL DIAGRAMS WITHOUT CONNECTOR WITH PRE-HEATER WITHOUT PRE-HEATER Black Brown   Blue Pre-heater WITH CONNECTOR WITH PRE-HEATER WITHOUT PRE-HEATER Black Brown   Blue Pre-heater S3 T2 T1 S3 T2 T1 B4: Contact of hour-counter. FR: Photocell sensor.
  • Page 9 - 7 - 16.- OIL EASY CONNECTION To connect and disconnect the red oil tube to the combustion line, proceed as follows: - Press the connector o-ring in the direction of the arrow shown below, and simultaneously pull the red tube. RED PIPE PRESS O-RING...
  • Page 10 - 8 - 17.- BURNER CONTROL OPERATING SEQUENCE The burner’s LMO control box has a reset button which is the key element for resetting the burner control and activating/deactivating the diagnosis functions. Botón de rearme The multi-colour LED on the reset button is the indicator for visual diagnosis.
  • Page 11 - 9 - 18.- BURNER ERROR CODE We have already mentioned that the burner is equipped with a cut-out system, indicated by the reset button light. It may cut out accidentally, and in this case the steady red light on this button will come on.
  • Page 12 Bº San Esteban s/n 20730 AZPEITIA 20737 RÉGIL (Guipúzcoa) Tel: (+34) 943 813 899 Fax: (+34) 943 815 666 www.domusateknik.com DOMUSA TEKNIK reserves the right to make modifications of any kind to *CDOC000017* its product characteristics without prior notice. CDOC000017 11/19...

This manual is also suitable for:

Domestic d-4Domestic d-3

Table of Contents