......GENERAL Document Purpose NOTE Figure 1. Front View of SDS5486LN Hereafter, the Westell INTELIPORT I Model SDS5486LN Is sue 4 will be referred to as the SDS5486LN" or the INTELI PORT." Document Status Product Features Product Purpose and Description...
Section SDS 548 6LN 204 XMT OUT Level Adjust LEVELS (IN DBM) PORT PORT *The XMT OUT level can be remotely adjusted for any level from +7 to 16 dBM (TLP) or 6 to 29 dBM (DLP) Table 1. Operating Levels Alignment (Remote and Automatic) 2.3.1 Remote Alignment...
Page 3
1200 S2–A AUTOMATIC S3–A RCV LEVEL POST CIRCUITRY EQUALIZATION 1200 S2–B 2713Hz FILTER AND DETECTOR TEK5 LPBK TEK6 RCV DATA DETECTOR FAIL/ ALIGN/ MNLB RELAY LPBK TEST TEST SUPPLY TERM MICROPROCESSOR SEALING CURRENT POWER SUPPLY MLBG OSCILLATOR TRANSPONDER ELECTRONIC 414Hz CIRCUITRY HYBRID SWITCH...
Page 4
Section SDS 548 6LN 204 FLASHING FLASHING NOTE The command mode is equipped with a 5 min timer circuit. If no tone is sent to INTELIPORT during the five minute time frame, INTELIPORT sends an error tone (ramp down tone from 3014 Hz to 314 Hz;...
Page 5
Section SDS 548 6LN 204 Remote (Manual) Alignment 3.11 Loopback NOTE INTELIPORT provides a built in five minute waiting period for each tone (1004, 2804, and 404Hz) to be returned by the STC. If no tone is sent to INTELIPORT during the 5 min time frame, INTELIPORT sends an error tone (ramp down tone of 3014Hz to 314Hz;...
Page 6
Section SDS 548 6LN 204 3.17 Quiet Term/Transponder Operation NOTE INTELIPORT's XMT OUT Level Adjust mode provides a built in five minute waiting period for each tone to be returned by the STC. If no tone is sent to INTELIPORT during the five minute time frame, INTELIPORT sends an error tone (ramp down tone of 3014 Hz to 314 Hz;...
Page 7
Section SDS 548 6LN 204 TEST TEST 1200 SUPPLY OFF TERM POSITION POSITION FUNCTION FUNCTION OPTION OPTION Table 3. SDS5486LN Switch Options 3.19 Sealing Current...
If the equipment has Table 4. Installer Connections been damaged in transit, immediately report the extent of the damage to the transportation company and to Westell (see Part 6 for telephone number). Power...
Section SDS 548 6LN 204 4W APPLICA 4W APPLICA PORT PORT TIONS APPLICATIONS *In 2W applications, the RCV OUT and XMT IN ports utilize the same transmission pairs (XMT, IN, T and R pins 55 and 49). Troubleshooting Table 5. Wire Test Mode Tones TESTING &...
Page 10
Section SDS 548 6LN 204 STEP STEP ACTION ACTION INSTALLER'S PROCEDURES Wire Test Mode Serving Test Center's Procedures Remote (Manual) Alignment Mode Auto Align Mode Table 6. Testing and Alignment Procedures...
Page 11
Section SDS 548 6LN 204 Loopback (After Alignment) Loopback (From Idle State) XMT OUT Level Adjust Mode To add Gain To add Loss To Set Level For 16 dBm NOTE Transponder Mode (TLP/DLP) Table 6. Testing and Alignment Procedures (Continued)
Page 13
Section SDS 548 6LN 204 SDS5486LN OPTIONAL TESTS XMT OUT LEVEL ADJUSTMENT TO ADD LOSS TO ADD LOSS TO OBTAIN 16 dBm TO OBTAIN 16 dBm TO ADD GAIN TO ADD GAIN NOTE: Maximum output level is +7 dBm (TLP) NOTE: Minimum output level is 16 dBm (TLP) NOTE: Optional tests are initiated from command mode.
Page 14
Section SDS 548 6LN 204 Point to Point Remote Alignment Procedure *Columns E and J equal Customer's RCV OUT level Table 9. SDS8486LN Point Point Remote Alignment...
Page 15
Section SDS 548 6LN 204 Table 9. SDS8486LN Point Point Remote Alignment (Continued)
Page 18
START SEND TONES RECORD LEVEL INTELIPORT SEND 2713Hz FOR INTELIPORT SEND IS TONE PRESENT FOR INTELIPORT RETURNS IS TONE PRESENT ENTERS ONE AT A TIME, OF EACH TONE 0.9 SEC MINIMUM RETURNS TO 2713Hz MORE THAN 2.0 SECONDS? 1–SEC., ALTERNATING FOR <30 SEC.? LOOPBACK LOOPED BACK...
Need help?
Do you have a question about the INTELIPORT I SDS5486LN and is the answer not in the manual?
Questions and answers