AO3/AO3W/AO5/AO5W Series
Medical Oxygen Concentrator

User Manual

www.rms-care.com
Official micro channel code

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the AO3 Series and is the answer not in the manual?

Questions and answers

Summary of Contents for RESPICARE AO3 Series

  • Page 1: User Manual

    specialized manufacturer of respiratory equipment Official micro channel code AO3/AO3W/AO5/AO5W Series Medical Oxygen Concentrator KINGSMEAD SERVICE LIMITED 145-157 St John Street, London, EC1V 4PY (UK) TEL:044-20-7193 9159 Manufacture: Shenyang RMS Medical Tech Co.,Ltd User Manual Address: No. 8-1, Gaoge Road, Hunnan New District, Shenyang, China Tel: 0086-024-23782895-8001 Fax: 0086-024-23782895-8008 www.rms-care.com...
  • Page 2: Table Of Contents

    Respiratory Medical Solutions Table of Contents Drip Proof Equipment IP21 Section 1- Special Notes Warnings NO smoking Cautions Radio Frequency Interference Intended Use Serial Number Section 2- Packaging And Handling Unpacking Indicating its conformity with the medical devices directive 93/42/EEC. Accessory List The 0917 is the number of notified body.
  • Page 3: Section 1 Special Notes

    Respiratory Medical Solutions Section 1 Special Notes 1.2 Cautions Please read all instructions before using.Important information is highlighted by these terms: ☻ Don’t smoke while using your oxygen equipment or when you are near a person Warning Warning indicates a hazardous situation which,if not avoided,could result in utilizing oxygen therapy.keep matches,cigarettes,burning tobacco,or candles away death or serious injury.
  • Page 4: Radio Frequency Interference

    Respiratory Medical Solutions ☻ Don't bend the oxygen tube in using, pick off the oxygen tube after turning off the Section 2 Packaging And Handling device. ☻ Never drop or insert any object or liquid into any opening. 2.1 Unpacking ☻...
  • Page 5: Section 3 Features

    Respiratory Medical Solutions Section 3 Features 3.1 Parts and Functions Filter Handle Warning Tag LCD Screen Flow Regulating Button Oxygen Outlet Control Buttons Inlet Filter Window Humidifier Bottle Oxygen Outlet Control Buttons Compressed Air Output Caste 3.2 Circuit Diagram Operation panel(Display,Button ) Circuit Breaker 3A 230L Control v alve...
  • Page 6: Section 4 Device Technical Indicators

    Respiratory Medical Solutions Section 4 Device Technical Indicators Section 5 Operating Instructions Rated flow 3L/min(AO3/AO3W) 、5L/ min( AO5/ AO5W) 5.1 Introduction 93±3% Up to 24 hours per day. Contionuous operation time RMS Series Medical Molecular Sieve Oxygen Concentrator adopts the theory of ≤40dB(A)(AO3/AO3W)、...
  • Page 7: Operating Pandl And Lcd Screen

    Respiratory Medical Solutions Connecting the humidifier bottle 5.4 Operating Panel and LCD Screen Connect the oxygen outlet in panel and the oxygen inlet in top of humidifier with the It is composed of buttons, indicator light and LCD screen, etc. oxygen connection tube.
  • Page 8: Operating Medthod

    Respiratory Medical Solutions Section 6 Cleaning And Maintenance Oxygen Operation interface: Display working 6.1 Cleaning and Maintenance m o d e , a l a r m i n f o r m a t i o n , o x y g e n Cautions:Unplug the power of device before cleaning to avoid the electrical shock.
  • Page 9: Section 7 Troubleshooting Guide

    Respiratory Medical Solutions Section 7 Troubleshooting Guide 7.2 Alarms 7.1 Troubleshooting There may be the following alarm information during using the device, please pay attentions: Alarms Description Action indicator flashing Oxygen irregular tube Smooth the irregular part of the tube Press start/stop the alarm stops Low Oxygen Concentration Continuous Alarm...
  • Page 10: Appendix A Emc Information

    Respiratory Medical Solutions Appendix A EMC Information IMMUNITY IEC 60601 test Compliance Electromagnetic environment –guidance test level level Guidance and Manufacturer’s Declaration Portable and mobile RF communications Warning equipment should be used no closer to any part Conducted RF 3 Vrms of the XXXXXXX, including cables, than the Medical Electrical Equipment needs special precautions regarding EMC and needs to recommended separation distance calculated...