  • Page 1 2-Easy Door Station Mod. DT601 Fingerprint 2-wire series Surface mount Flush mount www.intelligenthomeonline.com...
  • Page 2: Parts And Functions

    Introduction This door station is equipped with a high resolution colour ARS camera sensor with resolution 500TV Lines, with a wide angle of view 105 degrees. White LEDs enable the door station to work efficiently at night. The door station facia is made of stainless steel. There are both surface mount and flush mount versions. Door station is equipped with built-in Fingerprint Reader for up to 200 users.
  • Page 3: Terminal Descriptions

    Terminal Descriptions Lock Control Jumper P L S + B U S Main Connect Port • Lock Control Jumper: To program electric lock type • Main Connect Port: To connect the bus line and the electric lock • BUS: Connect to the bus line, no polarity •...
  • Page 4 Door Station Mounting Surface mount version will be supplied with stainless steel rain/mounting bracket. Flush mount version will be supplied with wall mounting box. Please use drawings below for installation tips Surface Version Mounting Drill holes in the wall to match the size of Connect the cable screws and attach the rain cover to the wall Attach the door station to the rain cover...
  • Page 5 Flush Version Mounting Cut a hole in the wall to match the size of the Connect the cable mounting box and install the wall box Attach th e door station to the mounting box and secure with screws 1- Monitor Kit Connection Diagram BUS(IM) BUS(DS) L1 L2 PL S+ S- Doorbell Button...
  • Page 6 Electric Lock Connection Electric lock can be powered from Door Station 1 2 3 Electric lock is ‘Power-on-to-unlock’ type The lock is 12V, and holding current is less Jumper position 2-3 than 250mA lock control is not timed from Exit Button (EB) The ‘Unlock Mode’...
  • Page 7 Unlock parameters setting (via monitor) INSTALLER SETUP About Local Address 00.00 Video Standard AUTO System Verson 00.01.00 Display Driver Front 1.Touch icon on 2.Touch UNLOCK 3.A digital keypad will main menu page button and hold for 2s be shown Notes: 1.
  • Page 8 Multiple Monitors Connection via Daisy-chain Code=15 Code=14 Code=0 100~240VAC BUS(IM) BUS(DS) Door Station ID Address:0 (default)
  • Page 9 Star Connection with DBC-4A distributor Impedance Code=15 Code=14 OFF ON switch Code=13 Code=12 Code=3 Code=2 Impedance OFF ON switch Code=1 Code=0 100~240VAC BUS(IM) BUS(DS) D oor Station ID Address:0 (default)
  • Page 10 Door Station Address/ID Setup Up to 4 x Door Stations can be connected to one system. In case if multiple Door Stations connected, they have to be assigned with unique Address/ID. First Door Station Address/ID would be 0 (default) Second Door Station Address/ID would be 1 Third Door Station Address/ID would be 2 Forth Door Station Address/ID would be 3 1)Power-on...
  • Page 11 Unlocking Time Settings The unlocking time can be set to 1~30 seconds. The default is 1s 1)Power-on Press and hold "KEY1" for 3 2) within 10 seconds Press and seconds hold "KEY2" for 3 seconds to enter the Programming mode LED 1 Buzzer LED 1...
  • Page 12 Door Station Ringtone Settings There are three options of ringtone: [A]-One ringtone, [B]-Continuous ringtone, [C]-No ringtone. The default is A- One ringtone 1)Power-on and within 10 Press and hold "KEY2" for 3 seconds seconds 2)Press and hold "KEY2" for 3 seconds, to enter the Programming mode LED 1...
  • Page 13 Master Fingerprint Creation Master Fingerprint enables you to register or delete user’s fingerprints and program or change parameters of programming i.e. unlocking time, ringtone and so on. The system can have one only Master ngerprint 1)Power-on and within 10 seconds Touch finger in the fingerprint window, get it identified first 2)Press and hold "KEY1"...
  • Page 14 Update Master Fingerprint If the system already has registered Master Fingerprint, it can be change to a new Master Fingerprint. Operation as follows: 1)Power-on and within 10 seconds Present original Master 2)Press and hold "KEY1" for Fingerprint, Confirm Master 3 seconds to enter Programming Fingerprint mode LED 1...
  • Page 15 User’s Fingerprints Registration The system can store up to 200 user’s ngerprints. Add User’s Fingerprints Press "KEY1" Present Master Fingerprint in standby mode to enter the state of user fingerprints setting LED 1 LED 2 Buzzer LED 1 LED 2 Buzzer (green) (off)
  • Page 16 Delete Specified User Fingerprint Press "KEY2" Present the Master Fingerprint in standby mode to enter the Programming mode LED 1 LED 2 Buzzer LED 1 LED 2 Buzzer beep,beep beep,beep (green) (off) (off) (flash quickly) Present the fingerprint you need to delete LED 1 LED 2...
  • Page 17 7.3 Delete All User Fingerprints Press and hold "KEY1" and Present Master Fingerprint in "KEY2" button at the same time standby mode to enter Programming mode LED 1 LED 2 Buzzer LED 1 LED 2 Buzzer beep+,beep beep+,beep (green) (off) (off) (double flash) Present Master Fingerprint to...
  • Page 18: Specifications

    Precautions • Please clean the unit with soft cotton cloth. Don't use organic impregnants or chemical cleaning agents. If necessary, please use a little pure water or dilute soapy water to clean the dust. • The unit is weather resistant. However do not spray high pressure water on access control keypad directly.
  • Page 19: Cables Requirements

    Cables Requirements This system transmits video and audio through the power cable. No Polarity connection. Recommended cables: twisted pair, power-flex multi-cores (stranded), speaker cable, CAT5/CAT6 Minimum requirements 0.5mm cable up to 2mm (depends on distance) monitor t wo or four monitors monitor monitor DBC4A...
  • Page 20: Warranty Card

    4. Attempting to force the device to perform functions for which it is not intended 5. Attaching the device to power supplies other than thoserecommended by the manufacturer Distributor for Warranty purposes: Intelligent Home Online Ltd 62 Hartley Old Road Purley, Surrey CR8 4HJ +44 (0)20 86170015 www.intelligenthomeonline.com...