Thank you for selecting an EasyStove interface unit. This product is the result of extensive research and experi- ence in heating system design. This manual is an integral part of the product and should be retained. Please read it carefully, as it provides important information regarding the installation and maintenance of the product.
Weight incl. Cover 11.0 kg PRINCIPAL COMPONENTS Heat Exchanger System Pump Air Vent Stove Circuit Pump Electrical Box Non Return Valve Cover Flow to System Return from System Return to Stove Flow from Stove Installation, Usage and Maintenance Instructions EasyStove...
HEAT EXCHANGER CHARACTERISTICS The EasyStove is designed for use with solid fuel stoves with a combustion output* of up to 20kW (max output to water* of 14kW) At Nominal Capacity Primary Stove Circuit Secondary Heating Circuit Flowrate L/h Temperature °C IN/OUT...
The 230V, 50Hz power supply must be protected by a suitable MCB. A flue thermostat must be mounted on the solid fuel boiler/stove and connected as a volt-free contact to the EasyStove. The ESBE CTF150 model flue thermostat is supplied with the EasyStove. SAFETY WARNINGS...
The scheme below will suit many systems. It takes account of the fundamental requirements outlined above. Some stoves and boilers will have a heat dissipation facility but if this is not present, the EasyStove heat dis- sipation kit should be installed as shown. The heat dissipation kit should be installed on the feed and expan- sion pipes as indicated.
WALL MOUNTING The EasyStove is normally supplied without a cover. If the unit is equipped with a cover, it should be re- moved and placed in a safe place. The cover is attached to the frame using four screws, two on the top and two on the bottom.
The installer should check all connections and tighten them if necessary to restore the compression of the gasket. The installer is responsible for ensuring that the entire system is watertight. NOTE Ensure thorough flushing of the system, to eliminate dirt, before commissioning. Installation, Usage and Maintenance Instructions EasyStove...
The electrical installation must be carried out by a qualified electrician. The equipment must be installed in accordance with IEE and all other relevant regulations. The EasyStove requires a 230 volts, 50Hz, single phase power supply. The power supply must be protected by a suitable MCB.
On increase of the temperature of the solid fuel boiler/stove, the TCcom -TCno contacts will move from CLOSED to OPEN. SCHEMATIC ESBE CTF150 Flue Thermostat RELE Pcam Fuse 1A Pcam Pcal Solid Fuel Pcal Stove 2. N/C contact max.16(2.5)A, 230VAC 4. N/O contact max.6.3(2.5)A, 230VAC Installation, Usage and Maintenance Instructions EasyStove...
09. COMMISSIONING Before operating the equipment, ensure that all air is purged from the EasyStove using the appropriate manual air vents and that the pump impeller of the pump is free to rotate. Ensure that all air is purged from the EasyS- tove Heat Dissipation kit (if used).
Maintenance and repair work must be performed by experienced technicians only. Disconnect the power supply before carrying out any work on the equipment. The EasyStove must be inspected annually to ensure correct operation and the absence of leaks. A record of the annual inspection should be preserved.