Ringer Capacitor
5.
15
An
externally-mounted QCCl 2A
capacitor
may be used
to
replace
an
open
or
shorted
ringer
capacitor
in
the
NE-425QEI
network. The
ringer capacitor is connected between
terminals A
and K
on the network
(Fig.
17).
INSULATING SLEEVE
-
SECTION 502-5101-201
5.16 When the ringer
capacitor is
shorted, it is
necessary to use
a
QCM l 2A connector
in
conjunction
with the QCC
l
2A capacitor. This
connector
consists
of a terminal for connecting
two spade-tipped
leads
together, and an insulating
sleeve.
(Fig.
17 .) Connect one side of the
QCC 12A
capacitor
to terminal A of
the
network;
leave
the
ringer
lead of this terminal.
Remove
the ringer
lead
from terminal K of the network, and connect it to
the
other side of the QCCl 2A
capacitor,
using the
QCM
l
2A connector.
5.17
Dress and
store
all
leads in a convenient
location,
keeping leads away from the ringer
gongs.
6.
ASSEMBLY
OF PARTS
6.01
Mechanical faults in
the
replaceable parts,
detected by visual inspection or electrical
.G-
QCM12A CONNECTOR
-;;:-
...........
~
Fig. 17
-
Replacing Defective
Ringer
Capacitor
816