Advertisement

TA-05KB-SMD
& TA-1K-SMD
Instruction & Operating manual
Warnung:
As with any form of electrical equipment, there is always a risk involved in the handling of electrical machinery. The
greatest care must always be exercised during installation and maintenance, and it is recommended this be carried
out by authorized personnel.
Pikatron GmbH • division TAE Antriebstechnik • Raiffeisenstrasse 10 • D-61250 Usingen
State 02.02.2017 V-2 TAE_BA TA-05KB_TA-1K_EN.PMD The German text applies in cases of doubt

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the TA-05KB-SMD and is the answer not in the manual?

Questions and answers

Summary of Contents for tae TA-05KB-SMD

  • Page 1 Pikatron GmbH • division TAE Antriebstechnik • Raiffeisenstrasse 10 • D-61250 Usingen State 02.02.2017 V-2 TAE_BA TA-05KB_TA-1K_EN.PMD The German text applies in cases of doubt...
  • Page 2: Table Of Contents

    TA-05KB-SMD & TA-1K-SMD able of conTenT 1 Technical data ....................2 2 Connection of the drive control (refer to connectiondiagramm) ....3 3 Drive control adjustment ..................3 4 Indicator lamps ....................3 5 Functional tests and preliminary adjustments before operating ....4 6 Troubleshooting ....................5 7 Connectiondiagramm ..................7...
  • Page 3: Connection Of The Drive Control (Refer To Connectiondiagramm)

    TA-05KB-SMD & TA-1K-SMD Connection of the drive control (refer to connectiondiagramm) Ensure that your a.c. line voltage corresponds to the voltage shown on the type marking of the unit. Terminal strip 1 – 2 AC input, voltage according to type marking on unit, frequency 50 or 60 Hz, terminal 1 -phase, terminal 2 -neutral.
  • Page 4: Functional Tests And Preliminary Adjustments Before Operating

    TA-05KB-SMD & TA-1K-SMD Functional tests and preliminary adjustments before operating a) Armature feedback control (UA -control) 1. Check all connections with an Ohmmeter for grounds. 2. Install resistor R8= 150k ohm (is built-in at delivery status at armature regulation). At tachometer regulation please demount.
  • Page 5: Troubleshooting

    TA-05KB-SMD & TA-1K-SMD Troubleshooting For fast end effective troubleshooting proceed as follows: Check drive for: a) intermittent and loose connections b) defective insulation of connecting leads c) defective motor (brushes etc.). CAUTION! Not use any Megohmmeter, buzzer or similar test instruments. Test instruments must be galvanical- ly separated from the AC line.
  • Page 6 TA-05KB-SMD & TA-1K-SMD Main fuse blows a) shorted or grounded armature or field connec- tions, defective SCR-bridge check field-diodes. b) defective motor or armature. Drive does not run a) defective power supply b) check function of relay and relay wiring (control release, terminals 7 and 8).
  • Page 7: Connectiondiagramm

    TA-05KB-SMD & TA-1K-SMD Connectiondiagramm Line TA-05KB Armature & TA-1K Field Speedpotentiometer Signal input Ground DC-Tachometer We reserve the right to correct technical and printing errors Instruction and Operating Manual...
  • Page 8: Dimensions

    TA-05KB-SMD & TA-1K-SMD Dimensions TA-05KB (with mounting plate) 112,5 TA-05KB Instruction and Operating Manual We reserve the right to correct technical and printing errors...
  • Page 9: Ta-1K (With Mounting Plate)

    TA-05KB-SMD & TA-1K-SMD TA-1K (with mounting plate) 112,5 TA-1K We reserve the right to correct technical and printing errors Instruction and Operating Manual...

This manual is also suitable for:

Ta-1k-smd

Table of Contents