SAFETY
The correct procedures for working at height must be adopted when installing this heater.
The heater must be installed by a suitably qualified person in accordance with current regulations.
CONTENTS.
Remove from carton and check contents:
- heater unit
- mounting bracket
- 2 no. M6 bolts, 2 no. shakeproof washers, 4 no. plain washers.
Ensure all packing material is removed and inlet/outlet grilles are clear.
LOCATION
.
This heater is designed for high level use above frequently used doorways. It must not be installed less than
1.8metres from floor level and the maximum recommended mounting height is 2.3m. It should not be
positioned immediately below a fixed socket outlet. Optimum performance is achieved when the heater is
positioned as close to the top of the door as possible. For wider doorways multiple units can be installed
giving a continuous curtain of hot air.
FIXING.
The heater can be mounted either a) directly to the wall or b) to the wall or ceiling using the bracket supplied.
a) The unit is mounted directly to the wall via two keyhole slots and fixed via two holes.
1) Securely fix two No.10 screws (not supplied) at 500mm centres 208mm above desired position for
outlet grille.
2) Slide unit over screws and ensure secure fixing.
3) For extra security the front cover can be removed and the two additional mounting holes used
.
(DISCONNECT FROM POWER SUPPLY BEFORE REMOVING COVER)
b) The bracket can be fixed to either the wall or ceiling provided secure fixings can be made
1) Remove plugs from holes in end of unit, loosely fit M6 bolts with 2 plain washers and shakeproof
washer closest to head.
2) Provisionally place in bracket to ascertain optimum location and mark fixing holes.
3) Remove from heater and securely fix bracket
4) Replace heater at appropriate angle and tighten bolts securely.
ELECTRICAL CONNECTIONS.
The Heater should be installed in accordance with the latest edition of the IEE Requirements for Electrical
Installation (BS 7671:2001) by a suitably qualified person.
The unit is NOT suitable for connection via a 13A plug and should be permanently connected to a suitable
230Vac 50Hz. power supply incorporating a means of isolation having a contact separation of at least 3mm
in all poles.
Connect as follows:-
Green-yellow wire to terminal marked E , with earth symbol
Blue wire to terminal marked N. Brown wire to terminal marked L
WARNING: THE HEATER MUST BE EARTHED.
or coloured green or green-yellow.
Reference
J008g

Advertisement

loading

Summary of Contents for CEH ODH-3000

  • Page 1 Reference Installation Instructions J008g ODH-3000 Over Door Heater SAFETY The correct procedures for working at height must be adopted when installing this heater. The heater must be installed by a suitably qualified person in accordance with current regulations. CONTENTS. Remove from carton and check contents:...
  • Page 2 Revision Date Replace 3way switch with 10/7/95 3 single way switches add external cut out 08/04 Schematic diagrams Motor Title ODH-3000 Over Door Heater Drawn by Date 21.11.93 Scale Drawing No. ODH-W-001 L011 Please keep these instructions for future reference The Manufacturers reserve the right to change the specification without prior notice EO&E...