1. Introduction This series’ product is a new generation of multi-function standalone access control. It adopts new ARM core 32-bit microprocessor design, which is powerful, stable and reliable. It contains reader mode and standalone access control mode etc.. It’s widely applied to different occasions, such as office, residential communities, villa, bank and prison etc..
5. Wiring No. Color Marks Description Green Wiegand input (Wiegand output as reader mode) White Wiegand input (Wiegand output as reader mode) Grey ALARM Alarm signal MOS tube drain output end (optional) Yellow OPEN/ BEEP Exit button input end (Beeper input as reader mode) Brown D_IN/ LED Door contact switch input (LED input as reader mode) (optional)
Page 4
6.2 Special Power Supply Note: The door contact and alarm function are optional 6.3 Reader Mode - 4 -...
7. Sound and Light Indication Operation Status Light indicator Buzzer Stand by Operation successful Green Beep— Operation failed Beep-Beep-Beep Admin card enter programming Beep-Beep Admin card exit programming Beep— Press digital key Beep Press * key Beep— Press access code Red indicator flash slowly Read card under card plus code mode Red indicator flash slowly...
Page 6
Add and Delete Users Enter Default Menu Operation steps Description programming value Read card Add card users or fingerprint users / Input a fingerprint twice... * continuously Press 8 or 10 digits card Add card users by card number number # … * Press ID number # read Add card users or fingerprint users “…”...
Page 7
Enter Operation Default Menu Description programming steps value Forbidden opening door Entry by code only Entry by card only Entry by card+ code/fingerprint + code Press * Admin code # Entry by card, fingerprint or code (Default admin code is Entry by fingerprint only "999999") Entry by fingerprint + card...
Page 8
Default Enter programming Menu Operation steps Description value Press * Admin code # new admin code # (Default admin code is Read card / Input a Set admin add card or admin add "999999") fingerprint twice * fingerprint Read card / Input a Set admin delete card or admin fingerprint twice * delete fingerprint...
Note: The add card is used to add card users continuously and quickly. When you read the admin add card at the first time, you will hear short "BEEP" sounds twice and the indicator light turns orange, it means you have entered into add user programming, when you read the admin add card at the second time, you will hear long "BEEP"...
11.2 Reset to Factory Default Users can reset to the factory default when the admin code is forgotten, or the default settings have been modified, operation as below: Power off, press and hold the # key or the exit button continuously, power on, release the # key or the exit button until hearing beep sound twice, the admin code has been reset to 999999, factory default settings are successful.