Pikatron GmbH • division TAE Antriebstechnik • Raiffeisenstrasse 10 • D-61250 Usingen TA-05C.PMD PT Änd.-Nr. 00003 Stand 12.03.2012 The German text applies in cases of doubt...
Page 2
TA-05/C TAE Antriebstechnik NOTE: After production all units are subjected to a quality control and an extensive functio- nal test, including a continuouse operation for 200 hours. Before delivery all units are again tested for their correct functioning. These extensive tests will assure that all supplied units are in perfect functional con- dition.
TA-05/C TAE Antriebstechnik About this Instruction Manual If you look for some definite topic you can use the table of contents at the beginning of these instruction and operation manual. In these instructions is a row of symbols which shall provide you with a fast orientation and show the importants.
TA-05/C TAE Antriebstechnik Instructions of safety Before you put the device into operation, please read this instruction and operation manual completely. The operation should only be done by quali- fied personal. The precautions and warnings below must be observed at the operation of the device.
TA-05/C TAE Antriebstechnik Technical data Dimensions refer to drawing chapter 10 Line Voltage 230VAC - 50/60Hz Power 0,7 kW Armature Voltage 180V Armature Current max. 6 Ampere eff. Field Voltage 210V Field Current max. 0,5 A Ambient temperature 0-40°C with armature feedback 3%...
= 28z end = 30z Current reference signal input. Current reference signal output. For speed control terminals 30d and 32d must be jumpered. Terminal for connection of TAE blocking protection B-200 (Nr.20003 F) or B202 (Nr. 20163 F). Adjustments Minimum speed Adjustment of minimum speed during operation.
TA-05/C TAE Antriebstechnik Indicators The following functions are indicated with LED´s: LED 1 green Line Supply LED 2 clear Thyristor triggering LED 3 yellow Drive release LED 4 Current limit, Over-speed Functional tests and adjustments before operation Caution ! Do not use any megohmmeter, buzzer or similar test instrument ! Measuring instruments must be galvanically seperated from line voltage.
TA-05/C TAE Antriebstechnik Adjustment of the I x R compensation (P5). Check for an approximate equal speed with and without motor load in the lower speed range. Turning the potentiometer clockwise will increase the speed under load. Note: if the compensation poten- tiometer is set too high, the drive will become unstable.
TA-05/C TAE Antriebstechnik Troubleshooting For fast and effective troubleshooting and for the location of defective componets pro- ceed as follows. Check drive for: a) Intermittent or loose connections b) Defective insulation of connecting leads c) Defective motor (brushes etc.) Fault location ...
Page 10
TA-05/C TAE Antriebstechnik Possible causes Symptom Speed varies without change of c) Defective supply (+/- 15V) for elec- speed potentiometer. tronic circuit. d) Defective SCR bridge. e) Defective tachometer or tachometer leads. f) Defective speed potentiometer. Main fuse blows. a) Shorted or grounded armature or field connections.