Summary of Contents for B-Max Technology B-Home

  • Page 2 TECHNICAL PARAMETERS...
  • Page 3 DELTA TEMPERATURE CONTROL Hysteresis for water temperature regulation When setpoint is reached the burner restarts Normally: 2 ° C (range 0-9) If the water temperature is adjusted to 60 °C, when the temperature drops to 58 °C the burner starts again...
  • Page 4 DELTA TEMPERATURE WAITING TIME This parameter represents the maximum level of water temperature Normally: 5 If the water temperature is adjusted to 60 °C, in case the temperature reaches 65 °C the burner turns off, it will start again when it reaches the temperature set with the parameter “Delta temperature control”...
  • Page 5 IGNITION ATTEMPS How many times the burner try to make the ignition before giving error Normally: 1...
  • Page 6 LAMP TIME Time that the LCD display remains illuminated backlight after any button is not pressed Normally: 5 min...
  • Page 7 ENABLE SECOND TANK NORMALLY : OFF to enable this parameter if a second tank is used...
  • Page 8 SWITCH ON EXTERNAL THERMOSTAT NORMALLY : OFF enables external thermostat ON = Enabled OFF = Disenabled...
  • Page 9 DISPLAY WATER TEMPERATURE This enables the visualization and water temperature management in the main display: ON = Enabled OFF = Disenabled...
  • Page 10 GENERAL PARAMETERS...
  • Page 11 MAXIMUM IGNITION TIME If within this time limit, the ignition is not made, the burner stops and give error Normally: 20 minutes...
  • Page 12 FLAME STABILIZING TIME After lighting the flame: flame stabilization time wait before declaring burner on...
  • Page 13 TIME BETWEEN CLEANINGS Time between cleanings When the time has elapsed, the burner makes the fan working at maximum power (for a duration indicated on next parameter “grill cleaning time”) in order to clean the combustion grill Normally: 040 minutes ( every 40 min it makes a cleaning cycle)
  • Page 14 GRILL CLEANING TIME Duration of the cleaning process, where the fan is working at maximum power Normally: 30 sec.
  • Page 15 ALARM DELAY Time delay in the activation of any alarm. Ex: If the temperature sensor is disconnected, it doesn’t give the alarm immediately, only after this time Normally: 120 sec.
  • Page 16 LUX MINIMUM START-UP Value that the optical sensor has to reach in order to considerate the ignition done. Not immediate, it should never go under the value assigned for a duration indicated on the parameter “TIM LUX Neutral Zone” Normally: 070...
  • Page 17 LUX TURNING OFF If this level is not mainteined, during the time settled on “TIM LUX Neutral Zone”, the burner stops The display gives error if this happen during the functioning Normally: 0040...
  • Page 18 PRE IGNITION TIME RESISTANCE Time assigned to the resistance in order to ignite the fuel and activate the burner Normally: 04...
  • Page 19 EXTERNAL THERMOSTAT TURNING OFF TIME Waiting time in order to turn off with external thermostat The option “External Thermostat enabling” on TECHNICAL PARAMETERS has to be activated If it’s 00, the burner remain in modulation modality without stopping (power 1) When it’s between 1 and 99, indicates the waiting time (minutes) before stop When it finishes to turn off, automatically restarts although the...
  • Page 20 TIM DEAD BAND LUX It represents the time in which the optical sensor has to detect, continuously, above the value “Minimum LUX start-up” Each time the detection value goes down, restarts the count Normally: 080 seconds...
  • Page 21 TURNING OFF TIME Time during which the fan is working at maximum power when the burner is turned off, in order to burn completely the residues remained on the grill. This cycle is activated before turn off the burner Normally: 6 (minutes)
  • Page 22 ALARM TURNING OFF TIME Time during which the fan is working at maximum power when the burner is turned off as the result of an alarm, in order to burn completely the residues remained on the grill. This cycle is activated when the burner is turned of Normally: 6 minutes...
  • Page 23 TIM FUEL PRELOADING This parameter regulates the time (seconds) of the first loading of pellets...
  • Page 24 INITIAL VENTILATION Power of ventilation during the first phase of ignition...
  • Page 25 TIME FEEDER SCREW MAX Time between a load of pellet and the other...
  • Page 26 FEEDER SCREW LOADING TIME Charging time between the preload and flame stabilization.
  • Page 27 FEEDER SCREW ON START Charging time during stabilization flame...
  • Page 28 FEEDER SCREW CLEANING TIME In case time of pellet loading coincides with time in which the fan is doing the cleaning at maximum power, just in this case the auger makes a loading for the time indicated in this parameter...
  • Page 29 TIM FEEDER SCREW POWER (1-5) It represents the time of loading made by the system for each power (from 1 to 5) There is a loading time for each power and it depends on the power desired and the fuel used...
  • Page 30 FAN SPEED ON LOADING It represents the power of the fan (in percentage) on charge phase...
  • Page 31 FAN SPEED ON STARTING It represents the power of the fan (in percentage) during flame stabilization...
  • Page 32 FAN SPEED ON CLEANING It represents the power of the fan (in percentage) during the cleaning phase Normally: 99...
  • Page 33 FAN SPEED IN POWER (1-5) Fan speed at each power Depends on the fuel (quantity and type) and chimney draft...
  • Page 34 MECHANICAL CLEANING INTERVAL MIN Time between mechanical cleanings...
  • Page 35 MECHANICAL CLEANING FORWARD SEC It regulates the output of the mechanical cleaning system the cleaning system goes out according to the time settled (1 sec = 1 cm, 2 sec = 2cm, etc)… It is not related to parameter “mechanical cleaning interval min”, this parameter activates the mechanical cleaning system after the feeder makes a load On low power is not useful it becomes useful on big powers...
  • Page 36 FAN SPEED IN FEEDER SCREW Fan speed on the external auger...
  • Page 37 SETTING PROCESS...
  • Page 38 INITIAL TARING Remove the plastic tube from the burner head in order to weigh each loading with a balance Start auger manually by pressing the button Weigh the pellet collected It is very important maximum precision...
  • Page 39 ADJUSTMENT WORKSHEET...
  • Page 40 Make a charge on a recipient ( with the black button on the side, for 2 min Weigh the pellet charged during this 2 minutes and put the value on “Weight” in the box and automatically the values (seconds of charge) for each level of power will be calculated on the green columns On PCI there is in this case 28 which indicates the kw power...