SAFETRAN systems 3000 GCP Software Upgrade Instructions

Installing software release 9v309-01e in the 80115 data recorder model

Advertisement

SOFTWARE UPGRADE INSTRUCTIONS
INSTALLING SOFTWARE RELEASE 9V309-01E IN THE
80115 DATA RECORDER MODEL
(FOR MODEL 3000 GCP)
May 2002 (Revised December 2008)
DOCUMENT NO. SIG-00-01-17
VERSION C
Safetran Systems Corporation, California Division
10655 7th Street, Cucamonga, California 91730
1-800-793-SAFE
Copyright © 2002 Safetran Systems Corporation
PRINTED IN U.S.A.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 3000 GCP and is the answer not in the manual?

Questions and answers

robert holland
April 30, 2025

We are experiencing a 9011 error which states --"low Ballast" I suspect that relates to the shunt units. Can you further elaborate as to cure?

Summary of Contents for SAFETRAN systems 3000 GCP

  • Page 1 INSTALLING SOFTWARE RELEASE 9V309-01E IN THE 80115 DATA RECORDER MODEL (FOR MODEL 3000 GCP) May 2002 (Revised December 2008) DOCUMENT NO. SIG-00-01-17 VERSION C Safetran Systems Corporation, California Division 10655 7th Street, Cucamonga, California 91730 1-800-793-SAFE Copyright © 2002 Safetran Systems Corporation PRINTED IN U.S.A.
  • Page 2: Proprietary Information

    WARRANTY INFORMATION SAFETRAN SYSTEMS CORPORATION warranty policy is as stated in the current Terms and Conditions of Sale document. Warranty adjustments will not be allowed for products or components which have been subjected to abuse, alteration, improper handling or installation, or which have not been operated in accordance with Seller's instructions.
  • Page 3: Software Version Identification

    PROM U10 of the Data Recorder module. The resident software version also appears as the second message displayed during event printout. To observe the sticker it is necessary to remove the Data recorder module from the 3000 GCP case as follows: Step 1 Set the 3000 GCP case POWER switch to the OFF position.
  • Page 4: Parts/Tools Required

    To initiate a Data Recorder event printout, refer to the applicable procedure described in the 3000 GCP Instruction and Installation manual. 9 309 9 309 FLASH PROM U10 80115f1 10-12-01 Figure 1. Flash PROM U10 Location B. WHEN AND WHERE TO UPGRADE The new software version may be uploaded into any 80115 module from a laptop computer in the field if so desired by the railroad.
  • Page 5 SYSTEM HISTORY STATUS TRACK 1 TRACK 2 PROGRAM EVENT NEXT DATA ERROR FUNCTION CLEAR ENTER SYSTEM SET UP RESET SERIAL PORT 80115 25-PIN RS-232 CONNECTOR 9V309f2 10-11-01 COM1 PORT 9-PIN RS-232 CONNECTOR Figure 2. 80115 Data recorder Module Serial Port to PC Interconnection Diagram Step 2 Connect personal computer serial port (COM1) to 80115 module 25-pin, RS-232...
  • Page 6 115f2.tif 10-12-01 Figure 3. Data Recorder Module Software Installation Setup Screen NOTE A 5001 error message may appear within the alphanumeric display while downloading the data recorder software. This error message should be ignored. Step 8 Set the MS/GCP POWER switch to OFF. Step 8.1 Set the Recorder Module CLEAR/OFF/PRINT toggle switch to the CLEAR position and hold, then set the MS/GCP POWER switch to ON.
  • Page 7 At the completion of boot program downloading, an Update dialog box displays within the Setup screen (see figure 5). 155f4.tif 10-12-01 Figure 5. Boot Program Update Dialog Box Step 9 Type Y. A boot reburn program Downloading window appears in the Setup screen (see figure 6).
  • Page 8 155f7.tif 10-12-01 Figure 7. Boot Program Update Success Window Step 10 Press any key. The Setup screen closes and the DOS window displays. Step 11 At C:\name of folder > prompt type INSTALL. Step 11.1 Press the Enter key. The Setup screen displays (see figure 2). Step 12 Set the MS/GCP POWER switch to OFF.
  • Page 9 155f8.tif Figure 8 Setup Program Download Window 10-12-01 At the completion of file downloading, an Update dialog box displays within the Setup screen (see figure 9). 155f9.tif 10-12-01 Figure 9. Setup Program Flash Memory Update Dialog Box Step 13 Type Y. A setup program Downloading window appears in the Setup screen (see figure 10).
  • Page 10 Verify that checksum displayed in Setup screen (circled on figure 11) is identical to checksum supplied with program disk. This completes application software installation. Step 15 Set the 3000 GCP case POWER switch to the OFF position. 8 of 8 Document No.: SIG-00-01-17 Version: C...
  • Page 11 1. Ensure that the new revision sticker covers the old revision sticker. Step 19 Return the Data Recorder Module to the proper slot in the 3000 GCP case. Ensure that the module is fully seated in the edge connector.