CyClone 2410-41 Maintenance & Support Manual

Front end processor
Table of Contents

Advertisement

Quick Links

The information in this document has been carefully checked and is believed to be entirely reliable. However, no
responsibility is assumed for inaccuracies. Furthermore, Cyclone Microsystems, Inc. reserves the right to make
changes to any products herein to improve reliability, function, or design. Cyclone Microsystems, Inc. neither
assumes any liability arising out of the application or use of any product or circuit described herein, nor does it
convey any license under its right or the rights of others.
2410-41
2410-42
2410-43
FRONT END PROCESSOR
MAINTENANCE &
SUPPORT GUIDE
Revision 1.0, May 2006
DO NOT RELEASED FOR DISTRIBTUION
Cyclone P/N 800-2410-
Copyright 2006 by Cyclone Microsystems, Inc.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 2410-41 and is the answer not in the manual?

Questions and answers

Summary of Contents for CyClone 2410-41

  • Page 1 Furthermore, Cyclone Microsystems, Inc. reserves the right to make changes to any products herein to improve reliability, function, or design. Cyclone Microsystems, Inc. neither assumes any liability arising out of the application or use of any product or circuit described herein, nor does it convey any license under its right or the rights of others.
  • Page 2 • Regulatory Compliance: UL 60950-1:2003, First Edition and CSA C22.2 No. 60950-1-03 1st Ed. April 1, 2003 Chapter 3.1 Installation Guidlines • Included Rack Mount Safety Warnings 2410-41, 2410-42 and 2410-43 FEP Maintenance & Support Guide Revision 1.0, May 2006...
  • Page 3: Table Of Contents

    FAN TRAY REMOVAL AND INSTALLATION ..................6-2 63.1 Fan / Filter Assembly Removal....................6-3 6.3.2 Fan/Filter Assembly Installation...................6-3 POWER SUPPLY REMOVAL AND INSTALLATION ...............6-3 6.4.1 Power Supply Removal .......................6-3 6.4.2 Power Supply Installation ....................6-3 2410-41, 2410-42 and 2410-43 FEP Maintenance & Support Guide Revision 1.0, May 2006...
  • Page 4 CHAPTER 8 OVERVIEW ............................8-1 HARDWARE.............................8-1 SOFTWARE AND FIRMWARE ......................8-1 EFFECTIVE PERIOD OF WARRANTY ...................8-1 REPAIRED OR REPLACEMENT PRODUCT (OUT-OF-WARRANTY) ...........8-1 SERVICE POLICY..........................8-2 APPENDIX A A.1 ADDITIONAL INFORMATION......................A-1 2410-41, 2410-42 and 2410-43 FEP Maintenance & Support Guide Revision 1.0, May 2006...
  • Page 5 Table 2-11. 10/100/1000 Ethernet Port Connector................2-12 Table 4-1. CPCI-824 Initialization LED Pattern Description ..............4-1 Table 5-1. Air Filter Replacement ......................5-1 Table 6-1. CLEI Number and Barcode ....................6-1 2410-41, 2410-42 and 2410-43 FEP Maintenance & Support Guide Revision 1.0, May 2006...
  • Page 6: Chapter 1 Introduction

    PRODUCT OVERVIEW INTRODUCTION The 2410-43, 2410-42 and 2410-41 Front End Processor is a system featuring six Gigabit Ehternet ports and six Megabit Ethernet ports. The Gigabit ports can operate at 10/100/1000Base-T and the Megabit ports can operate at 10/100Base-T. The system uses three PowerPC processors spread out between three identical hot swappable cards.
  • Page 7: Table 1-1. Specifications

    Current (Max): 6.5A Power Dissipation: 175 BTU/hr. Connector: Gigabit Ethernet ports: 10/100/100 BaseTx RJ45 10/100 BaseTx RJ45< 100 Megabit Ehternet ports: RJ11 Console Serial ports 75 ohm BNC,Transmit/Receive 2410-41, 2410-42 and 2410-43 FEP Maintenance & Support Guide Revision 1.0, May 2006...
  • Page 8 A prescrites dans le Reglement sur le brouillage radioelectrique edicte par le ministere des Communications du Canada. 2410-41, 2410-42 and 2410-43 FEP Maintenance & Support Guide Revision 1.0, May 2006...
  • Page 9: Figure 2-1. 600-2410-43-D0 Fep Front Panel

    Power Connector A Power Connector B FEP Power supply ON/OFF Switch CPCI-824 Reset Switch FEP Ground Lugs Power Supply A Power Supply B CPCI-824 CPCI-824 CPCI-824 Fan/Filter Assembly 2410-41, 2410-42, 2410-43 FEP Maintenance & Support Guide Revision 1.0, May 2006...
  • Page 10: Figure 2-2. 600-2410-42-D0 Fep Front Panel

    Power Connector A Power Connector B FEP Power supply ON/OFF Switch CPCI-824 Reset Switch FEP Ground Lugs Power Supply A Power Supply B CPCI-824 CPCI-824 Fan/Filter Assembly 2410-41, 2410-42 and 2410-43 FEP Maintenance & Support Guide Revision 1.0, May 2006...
  • Page 11: Physical Configuration (600-2410-41-D0)

    Name Power Connector A Power Connector B FEP Power supply ON/OFF Switch CPCI-824 Reset Switch FEP Ground Lugs Power Supply A Power Supply B CPCI-824 Fan/Filter Assembly 2410-41, 2410-42 and 2410-43 FEP Maintenance & Support Guide Revision 1.0, May 2006...
  • Page 12: Figure 2-4. 600-2410-43-A0 Fep Front Panel

    FEP Power supply ON/OFF Switch A Power Connector B FEP Power supply ON/OFF Switch B CPCI-824 Reset Switch FEP Ground Lugs CPCI-824 CPCI-824 CPCI-824 Power Supply A Power Supply B Fan/Filter Assembly 2410-41, 2410-42 and 2410-43 FEP Maintenance & Support Guide Revision 1.0, May 2006...
  • Page 13: Physical Configuration (600-2410-42-A0)

    FEP Power supply ON/OFF Switch A Power Connector B FEP Power supply ON/OFF Switch B CPCI-824 Reset Switch FEP Ground Lugs CPCI-824 CPCI-824 Power Supply A Power Supply B Fan/Filter Assembly 2410-41, 2410-42 and 2410-43 FEP Maintenance & Support Guide Revision 1.0, May 2006...
  • Page 14: Figure 2-6. 600-2410-41-A0 Fep Front Panel

    FEP Power supply ON/OFF Switch A Power Connector B FEP Power supply ON/OFF Switch B CPCI-824 Reset Switch FEP Ground Lugs CPCI-824 Power Supply A Power Supply B Fan/Filter Assembly 2410-41, 2410-42 and 2410-43 FEP Maintenance & Support Guide Revision 1.0, May 2006...
  • Page 15: Fep Front Panel

    Indicates CPCI-824 activity and will blink and/or vary in CPCI-824 ACT intensity as CPCI-824 performs different operations. 2410-41, 2410-42 and 2410-43 FEP Maintenance & Support Guide Revision 1.0, May 2006...
  • Page 16: Switches

    2.8.1 FEP Power Supply Switches The 600-2410-43-D0, 600-2410-42-D0 and 600-2410-41-D0 DC unit has a single power switch. This switch enables and disables power from both power entries to both power supplies. The ‘1’ position indicates power supply ON and ‘0’ position indicates power supply OFF.
  • Page 17: Fep Reset Switch

    Cable Clamp Manufacturer Mating Connector Backshell Backshell MS 3476 W14 4S ITT Cannon 057-0718-002 057-0685-002 MS 3475 W14 4S Deutsch MS 3476 W14 4S 94002-14-3014 94002-14-3014 2410-41, 2410-42 and 2410-43 FEP Maintenance & Support Guide Revision 1.0, May 2006...
  • Page 18: Ac Power Connectors

    CONFIGURATION & CONNECTORS -48 VDC -48 VDC Return Ground Figure 2-8. DC Power Connector The DC power wiring harness to 600-2410-43-D0, 600-2410-42-D0 and 600-2410-41-D0 should use 14 AWG wire and the color code as follows: Color Signal Contact -48 VDC...
  • Page 19: Ground Studs

    Diagnostic or debug activity may require connecting to the CPCI-824 console connector. A cable connecting the console port to a standard DB25 connector is available from Cyclone Microsystems (P/N 530-2006). A terminal (or PC running a terminal emulation program) should be set up for any baud up to 115K baud, 8 bits, no parity and 1 stop bit.
  • Page 20: 10/100/1000Base-T Ethernet Port Connector

    Not Used Not Used TRD3+ Input/Output Not Used TRD3- Input/Output Output TRD0- Input/Output Output TRD0+ Input/Output Not Used Not Used Not Used Not Used Not Used 2-12 2410-41, 2410-42 and 2410-43 FEP Maintenance & Support Guide Revision 1.0, May 2006...
  • Page 21: Instalaation Guidelines

    10.Reliable Earthing - Reliable earthing of rack-mounted equipment should be maintained. Particular attention should be given to supply connections other than direct connections to the branch circuit (e.g. use of power strips). 2410-41, 2410-42, and 2410-43 FEP Maintenance & Support Guide Revision 1.0, May 2006...
  • Page 22: Fep Initialization And Built-In Self Test

    Port 0 Act On Program executing from SDRAM. Port 0 Lnk On Port 1 Lnk On Port 1 Act On Port 2 Lnk On Port 2 Act On 2410-41, 2410-42 and 2410-43 FEP Maintenance & Support Guide Revision 1.0, May 2006...
  • Page 23 Entering pSOSystem. Port 3 ACT On, LEDs are under application control at this Port 3 Lnk On point. TFTP Boot application frimware does not utilize the LEDs. 2410-41, 2410-42 and 2410-43 FEP Maintenance & Support Guide Revision 1.0, May 2006...
  • Page 24: Periodic Maintenance

    The replacement of air filter or fan should be done with power off. The fan and air filter assembly is located on the left hand side of the FEP unit. Replacement filters can be purchased from Cyclone Micro- systems, Cyclone part number 370-1303.
  • Page 25: Figure 5-1 Air Filter Replacement

    PERIODIC MAINTENANCE Fans The filter slides out this way. Filter Figure 5-1. Air Filter Replacement 2410-41, 2410-42 and 2410-43 FEP Maintenance & Support Guide Revision 1.0, May 2006...
  • Page 26: Serviceable Components

    CPCI-824 Processor Board with Four Ethernet Ports ANC4SW0GAA 142029 370-1301-02 DC Power supply: 2410 Chassis ANPUL40MAA 142037 370-1300 Fan / Filter Assembly: 2410 Chassis GCNYAANFAA 436784 370-1303 Filter (only): 2400/2410Chassis 2410-41, 2410-42 and 2410-43 FEP Maintenance & Support Guide Revision 1.0, May 2006...
  • Page 27: Board Removal And Installation

    The cooling fans of the FEP are serviceable from the front of the unit. The FEP does NOT have to be removed from its rack to service the fans. 2410-41, 2410-42 and 2410-43 FEP Maintenance & Support Guide Revision 1.0, May 2006...
  • Page 28: Fan / Filter Assembly Removal

    With the printed circuit board of the power supply aligned with the card guides of the FEP unit, slide the power supply into the FEP. Fully seat the power supply and tighten the retaining screws. 2410-41, 2410-42 and 2410-43 FEP Maintenance & Support Guide Revision 1.0, May 2006...
  • Page 29: Chapter 7 Methodology

    • Component failure could result in FEP failure (except for the power supplies that are configured in parallel redundancy). However, Bellcore’s architecture uses FEPs in parallel redundancy. 2410-41, 2410-42 and 2410-43 FEP Maintenance & Support Guide Revision 1.0, May 2006...
  • Page 30: Configuration

    10000000 2400/2410 Chassis 600-2410-41-A0 CPCI-824 CM824-1G-T3 1460 684932 1614 619579 AC Power Supply: 2410 370-1302-02 2332 428816 2332 428816 Chassis Fan/Filter Assembly: 370-1300 10000000 10000000 2400/2410 Chassis 2410-41, 2410-42 and 2410-43 FEP Maintenance & Support Guide Revision 1.0, May 2006...
  • Page 31: Results

    7114 140568 600-2410-43-A0 5680 176,056 7274 137476 600-2410-42-D0 5192 192,604 5500 181818 600-2410-42-A0 5352 186,846 5660 176678 600-2410-41-D0 3732 267,953 3886 257334 600-2410-41-A0 3892 256,937 4046 247158 2410-41, 2410-42 and 2410-43 FEP Maintenance & Support Guide Revision 1.0, May 2006...
  • Page 32: Chapter 8 Overview

    Buyer returns the defective product, freight prepaid, to Cyclone. The only responsibilities of Cyclone under this warranty are at its option to replace or repair, without charge, any defective component of such products.
  • Page 33: Service Policy

    Cyclone or with respect to any non-standard products which have been subject to misuse, neglect, accident, or have been modified by the Buyer. Cyclone shall have no liability for incidental or consequential damages of any kind arising out of the sale, installation, or use of its products.
  • Page 34: Additional Information

    Additional information for each of the boards used in the FEP can be found in their respective User's Manual. These manuals are available from Cyclone Microsystems. Part Number Description 800-0824 CPCI-824 User's Manual 2410-41, 2410-42 and 2410-43 FEP Maintenance & Support Guide Revision 1.0, May 2006...

This manual is also suitable for:

2410-422410-43

Table of Contents