Installation - DeDietrich DWD1114/94 Manual To Installation

Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 12

4 / INSTALLATION

Before connecting the appliance to the power supply, check that the wires of
your electric installation have sufficient diameter to supply power to the
appliance normally. The fuse for the installation shouldbe 10 amps.
It is necessary to provide a bipolar cut-off device in the power supply circuit, where
the opening of the contacts is more than 3 mm.
The electric connection should be done before the appliance is set in the cabinet.
The drawer should be connected by a (standard) power cord with three 1 mm²
couplers (1 single phase + 1 N + ground) to the 220-240 V single phase power
supply via an electric circuit corresponding to the standard CEI 60083 or complying
with the installation rules. The protective wire (green/yellow) corresponds to
ground
on the appliance and should be connected to the ground of the
installation.
In the case of a connection via an electric outlet, the outlet should be accessible
after the installation of the appliance.
The neutral on the heating drawer (blue wire) should be connected to neutral on the
power supply.
WARNING : If the warming drawer malfunctions in any way, unplug
the appliance or remove the fuse corresponding to the sector where
the warming drawer is hooked up.
16

Advertisement

Table of Contents
loading

This manual is also suitable for:

Dwd1129

Table of Contents