INSTALLATION INSTRUCTIONS FOR 2-WIRE
AUTO START CONTROL CONVERSION
The following instructions are provided to convert the ULPSS8B4W/E
from a special 4-wire start system to a standard 2-wire Auto Start System.

Items required:

WINCO Conversion Kit # 16448-007 Auto Start
T25 Torx Screwdriver
7/16" End Wrench or Socket & Driver
Wire Side-Cutter
Wire Crimper

PROCEDURE

1. Remove right side panel, rear door, left side door and roof.
2. Move the left hand toggle switch "A" to the "STOP" position.
3. Locate the two wires connected to the left side of the engine. Remove the wires
from the bolt by taking the nut off. Cut the terminal connector off each wire. Crimp a
wire cap to each wire individually. Replace the nut. See picture on page 2..

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the ULPSS8B4W/E and is the answer not in the manual?

Questions and answers

Summary of Contents for DTI Dyna Technology ULPSS8B4W/E

  • Page 1 INSTALLATION INSTRUCTIONS FOR 2-WIRE AUTO START CONTROL CONVERSION The following instructions are provided to convert the ULPSS8B4W/E from a special 4-wire start system to a standard 2-wire Auto Start System. Items required: WINCO Conversion Kit # 16448-007 Auto Start T25 Torx Screwdriver 7/16”...
  • Page 2 4. Remove the battery negative (-) cable if the battery is installed. 5. Unplug the wiring harness “D”. 6. Remove the two bolts “B” and remove the circuit breaker cover panel. 7. Remove the 6 torx screws “G” from the tower assembly.
  • Page 3 19. Re-attach the battery cable if done so earlier. 20. Replace the right side access panel and roof. 21. Remove the operators manual part # 60706-210 for model ULPSS8B4W/E from the literature package and replace it with operators maual part # 60706-211 for model ULPSS8B2W/E.

Table of Contents