Download Print this page

Whitehall cleatPRO T-8-S-CC Operation And Care page 4

Advertisement

Instructions for Operation of cleatPRO Steamer
1
Make sure the unit
is unplugged and
all packaging has
been removed.
3
Place the cleat rack
inside the unit. Be
careful of the
heating element.
The water temperature for normal operating conditions is about 165°F (74°C). The thermostat is very sensitive; even a
small adjustment can raise or lower the temperature several degrees. The thermostat has an adjustable temperature
range of 65°F (18°C) to 175°F (79°C) ±5°F (-15°C). To adjust the temperature, you need a Thermometer capable of
180° F (83° C).
5
Facing the back of the
unit, find the metal
temperature stem
between the 2 screws
in the lower middle of
the unit. Attach knob.
3
WHITEHALL MANUFACTURING • P .O. BOX 3527 • City of Industry, CA 91744-0527 U.S.A
Phone (800) 782-7706 • (626) 968-6681 • Fax (626) 855-4862 • Web: www.whitehallmfg.com
FILLING your unit
FOR TECHNICAL ASSISTANCE CONTACT WHITEHALL MANUFACTURING
®
2
Check the drain
valve before filling.
Use the hose
provided. Fill unit
with 2" of tap water
for Model T-12-M-CC
and 1-1/2" for Model
T-8-S-CC.
NOTE:
ENSURE WATER
LEVEL IS
MAINTAINED
4
Insert shoes carefully into
unit.
NOTE: WHEN IN USE
ENSURE LID REMAINS
CLOSED SO STEAM DOES
NOT ESCAPE.
6
Using the knob, turn clockwise to increase the
temperature. Allow the temperature to stabilize, and
measure the water temperature with the
thermometer.
CAUTION: Sensitive thermostat - a small adjustment
changes several degrees. Temperature range of 65°F
(18°C) to 175°F (79°C) ±5°F (-15°C).
2"
(51)
TEMPERATURE

Advertisement

loading

This manual is also suitable for:

Cleatpro t-12-m-ccCleatpro et-12-m-ccCleatpro et-8-s-cc