ABLE OF ONTENTS DISCLAIMER The suggestions and recommendation within this document are intended as a guide for the installation of Fair-Play scoreboard, TLVision sports displays and/or Trans-Lux signs. While Fair-Play believes the instructions contained herein are accurate and correct, Fair-Play does not warrant the accuracy or correctness of such instructions and there are no warranties, expressed or implied and not limited to any warranties of merchantability of fitness for a particular purpose.
ABLE OF ONTENTS TABLE OF CONTENTS ............................1 NPACKING Scoreboard & Control ......................... 1 Signs ..............................1 & P ......................2 QUIPMENT OCATION LACEMENT Ventilation............................2 .............................3 ONTROL Wired Control Data Connections ......................3 .......................4 ORTABLE NDOOR COREBOARD Floor or Tabletop..........................4 Power and Data ...........................
Page 4
ABLE OF ONTENTS [This page is intentionally left blank] 98-0001-23 • 1805.03 NDOOR COREBOARD NSTALLATION ECOMMENDATIONS...
& P NPACKING QUIPMENT OCATION LACEMENT UNPACKING For convenience and to prevent possible damage to equipment, unpack the shipping containers at the installation site. CAUTION: The shipping crates and boxes must be unpacked on a sturdy and level floor. Take all precautions to prevent equipment from tipping and cause possible injury to personnel or damage to equipment.
& P NPACKING QUIPMENT OCATION LACEMENT EQUIPMENT LOCATION & PLACEMENT • The sports display (scoreboard, TLVision and optional sign) must be positioned so that the spectators see what is being displayed. • The control must be located such that the scorekeeper or control operator can monitor the event and see what is being displayed.
& P NPACKING QUIPMENT OCATION LACEMENT CONTROL The control must be operated and stored in a dry location. Refer to the user manual for the operation and maintenance of your control. WIRED CONTROL DATA CONNECTIONS The data cable(s) from the scoreboard(s) must be connected to the MP-70/50 or MP-80 as shown in the diagram below.
& P NPACKING QUIPMENT OCATION LACEMENT PORTABLE INDOOR SCOREBOARD FLOOR OR TABLETOP • Single Sided or Two Sided Tabletop models can be placed on the floor or on a table. • Single Sided or Two Sided models equipped with wheels are for use on the floor. •...
– F NDOOR COREBOARD IDED SSEMBLY INDOOR SCOREBOARD FOUR SIDED SCOREBOARD ASSEMBLY Four Sided Scoreboards require assembly on ground level before it can be hoisted to its final location. See Figure 5 below. 1. Arrange the scoreboards as shown. Secure scoreboards to corner angles using hardware supplied. 2.
– F NDOOR COREBOARD IDED SSEMBLY TANDARD HAIN 1. The data chain harness is the standard connection method used for a four sided scoreboard. Data from is fed to , from , and finally from SIDE 1 SIDE 2 SIDE 2 SIDE 3 SIDE 3 SIDE 4...
– F NDOOR COREBOARD IDED SSEMBLY PLITTER PTION A splitter is used on a four sided scoreboard when additional lamp drivers required; stat panels for example. Data is distributed from the to each scoreboard. DATA SPLITTER 1. Open the internal compartment – use any of the following methods: •...
– M NDOOR COREBOARD OUNTING MOUNTING THE SCOREBOARD AFETY EQUIREMENTS • Comply with all applicable city, county, state and federal laws and regulations adopted pursuant thereto. • Provide all measures necessary to protect the workmen and other persons during construction. Provide all necessary measures to avoid excessive stresses and to hold the structural elements in place during construction.
– M NDOOR COREBOARD OUNTING OUNTED Wall mounting is the preferred method of installation for , and there are two methods: SINGLE SIDED SCOREBOARDS • Tile Wall – Use a 3/8” toggle bolt with washer. Refer to Figure 10. • Masonry Wall –...
Page 14
– M NDOOR COREBOARD OUNTING 1 – M & M ABLE OUNTING IMENSIONS ETHODS WALL MOUNTED MODEL SIDES SUSPENDED FLOOR/TABLE BB-1500-4 Series 75-1/4” U-bolts option BB-1575-4 50” U-bolts option BB-1576-4 42” U-bolts option BB-1600-4 Series w/Stat Panels 75-1/4” 147-1/4” 36” U-bolts option BB-1600-4 75-1/4”...
– M NDOOR COREBOARD OUNTING USPENDED WARNING: Sectional or scoreboard models containing a “V” (xx-xxxx-V-xxxx) MUST NOT be suspended and must be wall mounted using the WALL BRACKET. WARNING: Failure to follow these guidelines could result in injury or death. Except for scoreboard models having a “V”...
– P & D NDOOR COREBOARD OWER POWER & DATA OWER • Provide a dedicated power circuit to the scoreboard. • All electrical hookups must meet local building codes including breaker sizing, grounding, and ground rod requirements. • The power wires from the main service disconnect to the fused disconnect must contain an earth ground conductor.
– P & D NDOOR COREBOARD OWER ROUND The proper grounding of the electrical circuits and the scoreboard is an important aspect of an installation to ensure reliable operation, reduce potential lightning damage and for safety. Refer to Figure 14 below and to Article 250.56 and 600 of the National Electric Code, and ANSI/IEEE 142- 1.6.6.
– P & D NDOOR COREBOARD OWER – W IRED ONTROL • Portable Indoor Scoreboard – a 10’ foot data cord (with plugs) is provided for connecting from the MP-70/50 control to the scoreboard. Refer to page 4. • Single Sided Scoreboard – a 10’ foot data cord (with plugs) is provided for connecting the MP-70/50 control to the .
– P & D NDOOR COREBOARD OWER INGLE IDED COREBOARD CAUTION: DO NOT route incoming power and data control cable in the same conduit as this may cause interference with the operation of the scoreboard. NOTE: DO NOT route cable through cable passages without using a grommet, plastic bushing, or edge protection.
Page 20
– P & D NDOOR COREBOARD OWER 15 – P IGURE OWER AND ONNECTIONS FOR COREBOARD 98-0001-23 • 1805.03 NDOOR COREBOARD NSTALLATION ECOMMENDATIONS...
– P & D NDOOR COREBOARD OWER IDED COREBOARD CAUTION: DO NOT route incoming power and data control cable in the same conduit as this may cause interference with the operation of the scoreboard. NOTE: DO NOT route cable through cable passages without using a grommet, plastic bushing, or edge protection.
Page 22
– P & D NDOOR COREBOARD OWER 16 – P & D IGURE OWER ATA TO IDED COREBOARD 98-0001-23 • 1805.03 NDOOR COREBOARD NSTALLATION ECOMMENDATIONS...
– P & D NDOOR COREBOARD OWER IDED COREBOARD CAUTION: DO NOT route incoming power and data control cable in the same conduit as this may cause interference with the operation of the scoreboard. NOTE: DO NOT pass cable through any cable passages without using a grommet, plastic bushing, or edge protection to protect the cable.
Page 24
– P & D NDOOR COREBOARD OWER 17 – P & D IGURE OWER ATA TO IDED COREBOARD 98-0001-23 • 1805.03 NDOOR COREBOARD NSTALLATION ECOMMENDATIONS...
– C NDOOR COREBOARD ONNECTION IAGRAMS CONNECTION DIAGRAMS 01-0001-01 D IRECT The data from the scoreboard control is connected directly to the scoreboard. 98-0001-23 • 1805.03 NDOOR COREBOARD NSTALLATION ECOMMENDATIONS...
– C NDOOR COREBOARD ONNECTION IAGRAMS 01-0001-16 W IRELESS Data from the scoreboard control is transmitted via G3 wireless radio to the scoreboard. 98-0001-23 • 1805.03 NDOOR COREBOARD NSTALLATION ECOMMENDATIONS...
– C NDOOR COREBOARD ONNECTION IAGRAMS 01-0001-17 F IDED IRECT IRED Data from the scoreboard control is transmitted via direct wire to the 4-sided scoreboard. 98-0001-23 • 1805.03 NDOOR COREBOARD NSTALLATION ECOMMENDATIONS...
– C NDOOR COREBOARD ONNECTION IAGRAMS 01-0001-18 F IDED IRELESS Data from the scoreboard control is transmitted via G3 wireless radio to the 4-sided scoreboard. 98-0001-23 • 1805.03 NDOOR COREBOARD NSTALLATION ECOMMENDATIONS...