Prism Universal Sling Range
User Manual
PL1 - Prism Universal User Guide - Doc 001 - Rev 10/2010

Advertisement

loading

Summary of Contents for Prism Medical UK Universal Child

  • Page 1 Prism Universal Sling Range User Manual PL1 - Prism Universal User Guide - Doc 001 - Rev 10/2010...
  • Page 2: Sling Inspection

    Prism Universal Sling Application The Universal sling is designed for ease of fitting and general purpose transfer. It can be used to transfer from the seated to recumbent position or from recumbent to seated. The person must be assessed by a competent person who must be fully trained in the suitability, application and fitting of the sling.
  • Page 3 Sling Dimensions Child Junior Small 1050 Medium 1215 1025 Large 1070 1350 1120 X Large 1150 1440 1200 All dimensions have a tolerance of +/- 20mm PL1 - Prism Universal User Guide - Doc 001 - Rev 10/2010...
  • Page 4 Hoisting from a chair Note: The person to be transferred shall be referred to as “the person”. Bring the leg sections along-side the person’s Introduce the sling by sliding it down between thighs and pull lightly to ensure that they are of the chair backrest and the person’s back until equal length.
  • Page 5 Hoisting from a lying position Using good manual handling techniques Pass the leg section under and up roll the person towards you so that they in-between the thighs. Ensure that as positioned onto their side. much of the leg section as possible is introduce the sling, roll half of the sling up pulled under the leg and that all creases underneath itself so that when the person...
  • Page 6: Ce Marking - Declaration Of Conformity

    CE marked in accordance with Directive 2007 / 47 / EEC . ……………………………. Signed : For Prism Medical UK PL1 - Prism Universal User Guide - Doc 001 - Rev 10/2010...
  • Page 7 SLING CARE: LAUNDERING GENERAL. Sensitive laundering of lifting slings will extend the service life of the product. Conversely, improper laundering will reduce the service life and possibly affect the strength and integrity of the sling. To be avoided: use of bleach at washing, particularly hypochlorite [may cause structural •...
  • Page 8 Comments If you have any questions regarding the use of this equipment, please contact Prism Medical UK, or your local authorised dealer. Unit 1, Tir Llwyd Industrial Estate, St Asaph Avenue, Kinmel Bay, Rhyl, Denbighshire, LL18 5JA Tel +44 (0) 845 409 2000 www.prismmedical.co.uk...