The TH113-R-GA regulator has a built-in Ground Fault Circuit
Interrupter (GFCI) and has been specifically designed for use with
WarmlyYours floor warming systems. The TH113-R-GA operates like
a dimmer allowing you to adjust the amount of power output by your
heating system. The ON/OFF switch is used to turn the regulator off
when the latter is not in use (e.g. in the summer).
CONDUIT TO
POWER SOURCE
6/17/99
1.
TEST button/light
ON/OFF Switch
Power Adjustment Dial
4" x 4" DEEP SQUARE BOX
WITH SINGLE GANG MUD
RING FOR CONNECTION
TO THERMOSTAT
- 1/2" CONDUIT IF ONLY
ONE ROLL IS USED
- 3/4" CONDUIT IF 2 OR 3
ROLLS ARE USED
WARMING SYSTEM
TH113-R-GA
Supplied Parts
One (1) regulator
Two (2) screws
Four (4) solderless connectors for copper wires
NOTE: Special CO/ALR solderless connectors must be used for
connecting aluminum conductors.
Installation
Turn off power to the heating system at the main electrical panel
to avoid electrical shock. The installation should be carried out
by a licensed, qualified electrician and must comply with local
electrical codes.
Install the regulator on a deep 4" x 4" (double gang) electrical
box with a single plaster ring.
Do NOT install the regulator in an area where it can be exposed
to water.
For a new installation, choose a location approximately 5 ft.
above the floor.
Connect the regulator to the power supply:
120 VAC: Connect L1 of regulator to the black wire of power
supply and L2 of regulator to the white wire of power supply.
240 VAC: Connect L1 of regulator to the black wire of power
supply and L2 of regulator to the red wire of power supply.
FROM POWER SOURCE
L2
L1
GROUND
THERMOSTAT
FROM ROLL
Back
HOT
GROUND
HOT
GROUND
FROM ROLL
User Guide
BRAIDED GROUND SHEATH
STRANDED CONDUCTOR CORE
TEFLON INSULATION
TEFLON INSULATION
WHITE
COLORED
400-113-024-A
2.

Advertisement

loading

Summary of Contents for Warmly Yours TH113-R-GA

  • Page 1 Do NOT install the regulator in an area where it can be exposed to water. For a new installation, choose a location approximately 5 ft. The TH113-R-GA regulator has a built-in Ground Fault Circuit above the floor. Interrupter (GFCI) and has been specifically designed for use with Connect the regulator to the power supply: WarmlyYours floor warming systems.