DY 4 Systems SCP-122 Getting Started Manual

3u compactpci single board computer
Table of Contents

Advertisement

Quick Links

DY 4 Systems SCP-122 Getting Started Manual

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SCP-122 and is the answer not in the manual?

Questions and answers

Summary of Contents for DY 4 Systems SCP-122

  • Page 1 Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment SERVICE CENTER REPAIRS WE BUY USED EQUIPMENT • FAST SHIPPING AND DELIVERY Experienced engineers and technicians on staff Sell your excess, underutilized, and idle used equipment at our full-service, in-house repair center We also offer credit for buy-backs and trade-ins •...
  • Page 2 Date: October 2003 SCP/DCP-122 3U C OMPACT INGLE OARD OMPUTER ETTING TARTED ANUAL DY 4 Systems Inc. 333 Palladium Drive Kanata, Ontario, Canada K2V 1A6 (613) 599-9199 Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 3 The information in this document is subject to change without notice and should not be construed as a commitment by Dy 4 Systems Inc. While reasonable precautions have been taken, Dy 4 Systems Inc. assumes no responsibility for any errors that may appear in this document.
  • Page 4: Table Of Contents

    YSTEMS ABLE OF ONTENTS 1. Product Overview ....................... 1-1 Introducing the SCP/DCP-122 ....................1-1 Features List ........................1-2 PMC Expansion ....................... 1-2 Physical Characteristics ......................1-4 Weight Limits ......................... 1-5 Dimensions ........................1-5 Mating Connectors ......................1-5 Electrical Characteristics ......................1-6 Power Requirements......................
  • Page 5 SCP/DCP-122 G ETTING TARTED ANUAL YSTEMS 812628 R 2003 EVISION CTOBER Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 6 FPGA Boot PROM Select ..................2-10 Figure 3.1: Installing a PMC Module on a DCP-122 ..............3-3 Figure 4.1: SCP-122 Terminal Connection via (BPK-122-000) Transition Module ......4-3 Figure 4.2: Digital I/O via the Transition Module............... 4-5 Figure 4.3: EIA-422 Channel 3 and Channel 4 Header Pins............4-7 Figure 4.4:...
  • Page 7 SCP/DCP-122 G ETTING TARTED ANUAL YSTEMS 812628 V 2003 ERSION CTOBER Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 8 YSTEMS IST OF ABLES Table 1.1: Maximum CCA Mass ..................... 1-5 Table 1.2: Dimensions of the SCP/DCP-122 ................1-5 Table 1.3: SCP/DCP-122 Board Current Requirements.............. 1-6 Table 2.1: Jumper Settings Summary ..................2-2 Table 2.2: Boot Flash Write Protect Jumper ................2-4 Table 2.3: Application Flash Write Protect Jumper..............
  • Page 9 SCP/DCP-122 G ETTING TARTED ANUAL YSTEMS 812628 V 2003 VIII ERSION CTOBER Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 10 YSTEMS REFACE URPOSE This manual provides an overview of the features and functions of the SCP/DCP-122 Single Board Computer and explains how to correctly install the card and verify its basic operation. UDIENCE This manual is intended for the reader who has a technical understanding of hardware engineering fundamentals, and a basic understanding of the CompactPCI architecture.
  • Page 11 SCP/DCP-122 G ETTING TARTED ANUAL YSTEMS COPE OF ANUAL This manual contains the following chapters: Chapter 1 - Product Overview. Provides general information about the features and functions of the SCP/DCP-122. Chapter 2 - Pre-Installation Tasks. Discusses tasks that must be performed prior to installing the SCP/DCP-122 in a chassis.
  • Page 12 YSTEMS Abbreviations Table 3 lists the abbreviations used to describe the size of a memory device or a range of addresses. 3: Abbreviations ABLE Abbreviation Convention 1 Kbyte 1,024 bytes 1 Mbyte 1,024 Kbytes 1 Gbyte 1,024 Mbytes Memory Unless otherwise stated, all memory addresses are shown in hexadecimal notation. Addresses Icons The following icons are used throughout this document:...
  • Page 13 SCP/DCP-122 G ETTING TARTED ANUAL YSTEMS 812628 V 2003 ERSION CTOBER Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 14: Product Overview

    RODUCT VERVIEW SCP/DCP-122 NTRODUCING THE Designed for space constrained applications, the SCP/DCP-122 offers the greatest processing power of any ruggedized 3U cPCI single board computer on the market today. Based on the IBM 750FX processor, it runs at a clock speed of 800 MHz while executing an impressive 1856 Dhrystone Millions of Instructions per Second (DMIPS).
  • Page 15: Features List

    SCP/DCP-122 G ETTING TARTED ANUAL YSTEMS EATURES • Based on the IBM PowerPC 750FX processor – 800+ MHz – 1856+ DMIPS – 100 MHz CPU bus speed – 512 Kbyte of Internal L2 Cache running at core processor speed • cPCI Bus –...
  • Page 16 YSTEMS RODUCT VERVIEW Figure 1.2 illustrates the architecture and major components of the SCP/DCP-122. 1.2: SCP/DCP-122 Functional Block Diagram IGURE BP_5V BP_3.3V IBM750FX 512K L2 Cache Clocks 800MHz Power Conversion Ctrl 1.4V Power 1.8V Sequencer 2.5V BP_5V BP_3.3V 3.3V BP_VIO CPU I/F 32/64 bit 33/66 MHz...
  • Page 17: Physical Characteristics

    HARACTERISTICS The following figures will help familiarize you with the location of the major components and connnectors of the SCP/DCP-122. Although the SCP-122 is used for illustration purposes, the board layout for the DCP version product is identical. 1.3: SCP-122 Component Side View...
  • Page 18: Weight Limits

    YSTEMS RODUCT VERVIEW The SCP/DCP-122 board has the following physical characteristics: EIGHT IMITS The mass of the SCP/DCP-122 board does not exceed the values specified in Table 1.1. 1.1: Maximum CCA Mass ABLE Card Type Weight (grams) DPMC SPMC IMENSIONS The SCP/DCP-122 is built on a CompactPCI-compatible single-height (3U) PWB.
  • Page 19: Electrical Characteristics

    SCP/DCP-122 G ETTING TARTED ANUAL YSTEMS LECTRICAL HARACTERISTICS OWER EQUIREMENTS The SCP/DCP-122 maximum and typical power requirements are listed in Table 1.3. 1.3: SCP/DCP-122 Board Current Requirements ABLE Voltage Maximum Current Typical Current +3.3V (+5%, -3%) 1.1 A 0.9 A +5V (+5%, -3%) 2.2 A 1.8 A...
  • Page 20: Overview Of Supplied Firmware

    YSTEMS RODUCT VERVIEW VERVIEW OF UPPLIED IRMWARE OUNDATION IRMWARE The SCP/DCP-122 is programmed with the following Foundation Firmware (FFW) modules: • General Purpose Monitor (GPM): provides comprehensive monitoring and debug func- tions, which can be accessed from a terminal connected to the SCP/DCP-122 serial channel 1 interface •...
  • Page 21 SCP/DCP-122 G ETTING TARTED ANUAL YSTEMS 812628 V 2003 ERSION CTOBER Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 22: Pre-Installation Tasks

    NSTALLATION ASKS NTRODUCTION This chapter explains how to configure the SCP/DCP-122 before it is installed in a CompactPCI chassis. Specifically, this chapter provides the following information: • unpacking the card • modifying the SCP/DCP-122 jumper settings • checking cable and power requirements. NPACKING THE This card uses components that are sensitive to electrostatic discharges.
  • Page 23: Configuring Jumpers

    SPMC/DPMC-122 G ETTING TARTED ANUAL YSTEMS ONFIGURING UMPERS Depending on your application, it may be necessary to modify the default jumper settings on your SCP/DCP-122. For information about your card’s default configuration, refer to the Product Release Note. Cross Reference Table 2.1 summarizes the user-configurable jumper settings.
  • Page 24: Figure 2.1: Scp/Dcp-122 Jumper Locations

    YSTEMS NSTALLATION ASKS 2.1: Jumper Settings Summary (Continued) ABLE Configure FPGA from Back-up PROM (Reserved): A provision for a Back-up PROM for the FPGA exists in the Open E13-E14 design of the SCP/DCP-122, however it has not been imple- mented at the present time, meaning the jumper at E13-E14 must not be connected.
  • Page 25: Boot Flash Write Protect Jumper

    SPMC/DPMC-122 G ETTING TARTED ANUAL YSTEMS LASH RITE ROTECT UMPER The SCP/DCP-122 provides a jumper to allow programming of the main boot Flash. Normally, the E1-2 jumper is not installed and the boot Flash is write-protected. To program the boot Flash, install the E1-E2 jumper. 2.2: Boot Flash Write Protect Jumper ABLE Option...
  • Page 26: 2.3: Application Flash Write Protect Jumper

    YSTEMS NSTALLATION ASKS PPLICATION LASH RITE ROTECT UMPER The SCP/DCP-122 provides a jumper to allow programming of the application Flash. “Application Flash” means all Flash areas except the PABS Flash. The application Flash is in the range 0xFC00 0000 to 0xFDFF FFFF. For normal operation, remove jumper E3-E4 to write-protect the application Flash.
  • Page 27: Pabs Flash Write Protect Jumper

    SPMC/DPMC-122 G ETTING TARTED ANUAL YSTEMS PABS F LASH RITE ROTECT UMPER The SCP/DCP-122 provides a jumper to allow programming of the PABS (Permanent Alternate Boot Site) Flash area. This jumper is intended for factory use only. Caution For normal operation, remove the jumper E5-E6 so that the PABS is write-protected. To enable programming of the PABS Flash, install the E5-E6 jumper.
  • Page 28: Boot From Pabs Memory

    YSTEMS NSTALLATION ASKS PABS M EMORY The SCP/DCP-122 includes a 32-bit Flash bank and a PABS site. You may boot the SCP/DCP- 122 from either of these sources. Normally, the SCP/DCP-122 boots from 32-bit Flash. However, if the Foundation Firmware in the 64-bit Flash is corrupted, you may boot from the PABS site.
  • Page 29: Watchdog Timer Behaviour

    SPMC/DPMC-122 G ETTING TARTED ANUAL YSTEMS ATCHDOG IMER EHAVIOUR The SCP/DCP-122 offers the capability of enabling the watchdog timer immediately following reset without the need for software programming or initialization. This mode of operation is selected by leaving E9-E10 open. The watchdog timer will generate a card reset if left to expire.
  • Page 30: Figure 2.7: Execution Sequence Control Jumper

    YSTEMS NSTALLATION ASKS XECUTION EQUENCE ONTROL UMPER The SCP/DCP-122 has a software-readable jumper located at E11-E12. This jumper, referred to as the User Link or Software Switch, is used to control the power-up sequence for the Foundation Firmware and applications. The on-board Foundation Firmware checks the state (connected or open) of the User Link on power-up and uses this along with the serial channel 1 DSR input to select one of four possible execution sequences.
  • Page 31: Backup Fpga Boot Prom Jumper (Reserved)

    SPMC/DPMC-122 G ETTING TARTED ANUAL YSTEMS FPGA B PROM J ACKUP UMPER ESERVED The SCP/DCP-122 has a provision for a jumper to select a backup FPGA boot PROM, however no backup FPGA boot PROM is implemented in the current design of the SCP/DCP-122. Therefore the jumper E13-E14 must be removed in order to use the normal FPGA boot PROM.
  • Page 32: Installing Pmc Modules On The Scp/Dcp-122

    PMC M NSTALLING ODULES ON THE SCP/DCP-122 EFORE EGIN PMC modules include components that are sensitive to electrostatic discharges. Keep your PMC module in its conductive package until just before the installation begins. Remove the card from its protective package only at a grounded workstation while wearing an approved grounding wrist strap.
  • Page 33: Installation Procedure

    Install your PMC module on the SCP/DCP-122 using the appropriate mounting kit available from Dy 4 Systems. This kit contains all the screws and additional hardware you need to ensure that the PMC module is firmly installed on your SCP/DCP-122.
  • Page 34 PMC M SCP/DCP-122 YSTEMS NSTALLING ODULES ON THE 3.1: Installing a PMC Module on a DCP-122 IGURE 2 mm screws 2.5 mm screws w/washers (typ.) Integral Standoffs 812628 V 2003 ERSION CTOBER Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 35 SCP/DCP-122 G ETTING TARTED ANUAL YSTEMS 812628 V 2003 ERSION CTOBER Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 36: Hardware Installation

    ARDWARE NSTALLATION NTRODUCTION This chapter explains how to install the SCP/DCP-122 in a CompactPCI chassis. Specifically this chapter describes the following procedures: • inserting the card into a chassis • connecting a terminal to the card via a serial communications cable •...
  • Page 37: Inserting The Card In A Chassis

    SCP/DCP-122 G ETTING TARTED ANUAL YSTEMS NSERTING THE ARD IN A HASSIS EFORE EGIN This card uses components that are sensitive to electrostatic discharges. It must be kept in its conductive package until just before the installation begins. Remove the card from its protective package only at a grounded workstation while wearing an approved grounding wrist strap.
  • Page 38: Connecting A Terminal

    RS-232 connector provided on the SCP/DCP-122 transition module (Dy 4 order number BPK- 122-000) available from Dy 4 Systems (for use with either the SCP or DCP product versions). Default serial communication parameters are 9600 N, 8, 1 (9600 baud, no parity, 8 bits, 1 stop bit).
  • Page 39: Table 4.3: Usb Connector (Bpk-122-000 J4) Pinout

    SCP/DCP-122 G ETTING TARTED ANUAL YSTEMS BPK-122-000 Table 4.1 summarizes the pinout information for the BPK-122-000 J3 (RJ-12) connector. Serial Channel 1 4.1: Serial Channel 1 RS-232 Connector (BPK-122-000 J3) Pinout ABLE EIA-232 Interface J3 Pin Number SCP/DCP-122 Signal Name No Connect No Connect BPK-122-000...
  • Page 40 YSTEMS ARDWARE NSTALLATION BPK-122-000 Table 4.4 summarizes the pinout information for the BPK-122-000 J5 (RJ45) connector. Ethernet Interface 4.4: Ethernet Connector (BPK-122-000 J5) Pinout ABLE J5 Pin Number SCP/DCP-122 Signal Name ENET_TX+ ENET_TX- ENET_RX+ ENET_RX- BPK-122-000 The SCP/DCP-122 Digital I/O (DIO) signals are also available via header pins on the Transition Module transition module, as shown below in Figure 4.2.
  • Page 41: Table 4.5: Dio Header Pinout

    SCP/DCP-122 G ETTING TARTED ANUAL YSTEMS 4.5: DIO Header Pinout ABLE DIO Pin Signal Name DIO Pin Signal Name DIO Pin Signal Name Number Number Number DIO0/RTC Standby DIO8 DIO1 DIO9 DIO2 DIO10 DIO3 DIO11 DIO4 DIO12 DIO5 DIO13 DIO6 DIO14 DIO7/ALTBOOT DIO15...
  • Page 42: Bpk-122-000 Transition Module

    YSTEMS ARDWARE NSTALLATION BPK-122-000 Figure 4.3 shows the location and orientation of the header pins on the transition module Transition Module associated with the Channel 3 and Channel 4 EIA-422 interfaces available from the Channel 3 and 4 SCP/DCP-122. Header Pins 4.3: EIA-422 Channel 3 and Channel 4 Header Pins IGURE Cable...
  • Page 43 SCP/DCP-122 G ETTING TARTED ANUAL YSTEMS Basecard I/O Mode The default configuration assumes no PMC module is present on the SCP/DCP-122, allowing the full range of basecard I/O to be distributed via the transition module. This includes the following interfaces: •...
  • Page 44 CPCI RS-422 Ch3 and Ch 4 J5 Eth Ch 1 RS-232 Ch 2 RS-232 Reset (E36, E37) CBL-700-001 SCP-122 with PMC-700 installed 812628 V 2003 ERSION CTOBER Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 45: Table 4.8: Transition Module P0 Row A Signal Mapping

    SCP/DCP-122 G ETTING TARTED ANUAL YSTEMS P0 Cable Interface The following tables show how signals are mapped from the SCP/DCP-122 J2 interface Pinout through the transition module to each row of the P0 Cable Interface connector on the transition module. 4.8: Transition Module P0 Row A Signal Mapping ABLE P0 Cable...
  • Page 46: Table 4.9: Transition Module P0 Row B Signal Mapping

    YSTEMS ARDWARE NSTALLATION 4.9: Transition Module P0 Row B Signal Mapping ABLE P0 Cable CBL-SBC-P0-000 CBL-700-001 SCP/DCP-122 Signal Name (J2 Interface Pin #) Interface Row B Pin Number ENET2_UTP1 ENET_GND1 ENET2_TXD+ ENET_TXD+ ENET_TX+ (J2-D21) ENET2_RXD+ ENET_RXD+ ENET_RX+ (J2-C20) PMC_04 TX0+ PMC_04 (J2-A18) PMC_09 PMC_09_DIO2 (J2-A17)
  • Page 47: Table 4.10: Transition Module P0 Row C Signal Mapping

    SCP/DCP-122 G ETTING TARTED ANUAL YSTEMS 4.10: Transition Module P0 Row C Signal Mapping ABLE P0 Cable CBL-SBC-P0-000 CBL-700-001 SCP/DCP-122 Signal Name (J2 Interface Pin #) Interface Row C Pin Number DIO (15) CH1TXD A12/C8 A19, B19-B21 CRESET- CRESET PB_RST- (J2-C17) PMC_03 TXC+ PMC_03 (J2-D18)
  • Page 48: Table 4.11: Transition Module P0 Row D Signal Mapping

    YSTEMS ARDWARE NSTALLATION 4.11: Transition Module P0 Row D Signal Mapping ABLE P0 Cable CBL-SBC-P0-000 CBL-700-001 SCP/DCP-122 Signal Name (J2 Interface Pin #) Interface Row D Pin Number DIO (14) CH1RXD C9 / D12 Reserved CARDFAIL- PMC_02 TX0- PMC_02 (J2-B18) PMC_07 PMC_07_DIO1 (J2-B17) PMC_12...
  • Page 49: Table 4.12: Transition Module P0 Row E Signal Mapping

    SCP/DCP-122 G ETTING TARTED ANUAL YSTEMS 4.12: Transition Module P0 Row E Signal Mapping ABLE P0 Cable CBL-SBC-P0-000 CBL-700-001 SCP/DCP-122 Signal Name (J2 Interface Pin #) Interface Row E Pin Number DIO (13) CH1DSR DSR (J2-B12 / C7) DIO (9) PIO (9) PMC_39_DIO9 (J2-E10) DIO (10)
  • Page 50: Controlling The Boot Sequence

    YSTEMS ARDWARE NSTALLATION ONTROLLING THE EQUENCE The boot sequence for the Foundation Firmware depends on the settings of the User Link and the state of the Serial Channel 1 DSR line. The possible power-up sequences are shown in Table 4.13. 4.13: Foundation Firmware Execution Sequence ABLE Condition...
  • Page 51: Initiating The Power-Up Sequence

    I/O data is being received from the serial data port. The GPM will then display a sign- on message similar to the following: SCP/DCP-122, PowerPC 750FX General Purpose Monitor, Version 8.0 (c) DY 4 Systems Inc. Type ? for help 40000000* The last line is the initial prompt which shows the PCI base address of the card.
  • Page 52: Troubleshooting

    GPM drt command to display the DRT as shown in the example below: 4.6: Sample Diagnostics Results Table (DRT) IGURE SCP/DCP-122, PowerPC 750FX General Purpose Monitor, Version 8.0 Copyright 1998 to 2003 DY 4 Systems Type ? for help 40000000* drt DRT header address: 0x5400...
  • Page 53 SCP/DCP-122 G ETTING TARTED ANUAL YSTEMS Summary;: Pass Pass: Pass Cpu Space Decode; : Pass EPROM transfer: Pass RAM data convergence: Pass RAM address convergence: (0x0003ABD4-0x0003BB70) Pass RAM misaligned transfer: Pass RAM read/write: (0x0003ABD4-0x0003BB70) Pass UART Reset Condition: Pass UART Controllable bits: Pass UART Loopback: Pass UART Reset Condition: Pass UART Controllable bits: Pass...
  • Page 54 YSTEMS ARDWARE NSTALLATION 40000000* Drt results after reset: SCP/DCP-122, PowerPC 750FX General Purpose Monitor, Version 8.0 Copyright 1998 to 2003 DY 4 Systems Type ? for help 40000000* drt DRT header address: 0x5400 Binary DRT address: 0x5440 Diag Result Progress...
  • Page 55 YSTEMS ARDWARE NSTALLATION RAM data convergence: Pass RAM misaligned transfer: Pass RAM read/write: (0xF4008000-0xF400FFEC) Pass Partition checksum: Pass ISP1160 Reset Condition: Pass ISP1160 Controllable bits: Pass ISP1160 Reg Data Convergence Test: Pass FPGA Timer Run Test: Pass FPGA Timer INT Test: Pass L2 RAM Data Test: Pass L2 RAM Address Test: Pass L2 Cache Miss Test: Pass...
  • Page 56: Sign-On Message Garbled

    Instructions,” in Chapter 1 of your BSP Software User’s Manual. Give careful consideration to the specific references to the SCP/DCP-122 that this document makes. Additional troubleshooting assistance is available via the Dy 4 Systems TechNet web site, which includes a “Troubleshooting Wizard” to assist you with a number of typical problems, and answer many frequently asked questions.
  • Page 57 SCP/DCP-122 G ETTING TARTED ANUAL YSTEMS 4-22 812628 V 2003 ERSION CTOBER Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 58 Index About Card Insertion Force 4-2 EIA-422 Channel 3 and Channel 4 Header Pins 4-7 Application Flash Write Protect Jumper 2-5 EIA-422 Channel 3 Pinout 4-7 EIA-422 Channel 4 Pinout 4-7 Electrical Characteristics 1-6 Enable Booting from PABS Memory 2-7 Ethernet Connector (BPK-122-000 J5) Pinout 4-5 Backplane Connectors 1-5 Execution Sequence Control Jumper 2-9...
  • Page 59 SCP-122 Component Side View 1-4 SCP-122 Solder Side View 1-4 SCP-122 Terminal Connection via (BPK-122-000) Transition Module 4-3 SCP-122 Terminal Connection via Transition Module Serial Channel 1 RS-232 Connector (BPK-122-000 J3) Pinout 4-4 Sign-on Message Garbled 4-21 Status LED Stays Red 4-17...
  • Page 60 Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment SERVICE CENTER REPAIRS WE BUY USED EQUIPMENT • FAST SHIPPING AND DELIVERY Experienced engineers and technicians on staff Sell your excess, underutilized, and idle used equipment at our full-service, in-house repair center We also offer credit for buy-backs and trade-ins •...

This manual is also suitable for:

Dcp-122

Table of Contents