492 021 Memcom MPS

Installation Guide

Ref No. 492 856 (ML) Version 1
The Memcom Multi Point Station (MPS) provides external emergency telephone points for the lift engineer in the shaft,
pit or machine room. This easy to install unit also allows local communication between different points of the lift
installation through an intercom channel, which is a considerable benefit during commissioning and installation of the
elevator. The system has a unit status LED which informs the installer if the station is functioning and whether the alarm
button has been pressed. The ability to adjust the volume on the station without removing the product casing, saves
time and reduces the risk of feedback.
Using a two wire connection, up to 3 MPS units can be wired in parallel or series back to the Memcom and will be
powered by the Memcom integral battery. Further additional stations can be added, but will need to be boosted by
connecting a 24V DC power supply to each additional station.
Terminal Connection Block in Memcom
MPS stations (492 021) connected in
parallel / serial

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 492 021 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Memco 492 021

  • Page 1: Installation Guide

    Memcom integral battery. Further additional stations can be added, but will need to be boosted by connecting a 24V DC power supply to each additional station. Terminal Connection Block in Memcom MPS stations (492 021) connected in parallel / serial...
  • Page 2: Adjusting The Volume

    01628 540100 Unit 1, The Switchback 01628 540 100 Gardner Road 01628 621 947 Gardner Road 01628 621 947 Maidenhead sales.uk@avire-global.com Maidenhead sales.uk@avire-global.com Berkshire www.memco-global.com Berkshire SL6 7RJ, UK www.memco-global.com SL6 , UK www.avire-global.com www.avire-global.com Memco is a brand of Avire...
  • Page 3 über den eingebauten Akku mit Spannung versorgt werden. Weitere zusätzliche MPS Stationen können mit angeschlossen werden, benötigen jedoch eine separate 24V DC Spannungsversorgung zu jeder einzelnen MPS Station. Anschlussblock am Memcom MPS Stationen (492 021) angeschlossen in parallel / seriell...
  • Page 4: Einstellen Der Lautstärke

    Das Gerät kann an der Wand oder unter der Kabine mittels der beiden Befestigungslöcher an beiden schmalen Seiten des Gehäuses durch die mitgelieferten M4,2 Selbstschneidschrauben befestigt werden. Avire Ltd Handwerker Strasse 6 09721/608511 97526 Sennfeld 09721/608544 Deutschland sales.de@avire-global.com Memco is a brand of Avire www.memco-global.com www.avire-global.com...
  • Page 5: Guide D'installation

    Memcom et seront alimentées par la batterie interne du Memcom. Des stations SMP supplémentaires peuvent être ajoutées, mais elles devront être alimentées par une source extérieure de 24Vdc. Connexion sur le bornier principal du Memcom Stations SMP (492 021) connectée en parallèle/série...
  • Page 6: Réglage Du Volume

    Avire Ltd ZAC Des Portes de l’Oise (+33) 01 30 28 95 39 9 BIS Rue Léonard de Vinci (+33) 01 30 28 24 66 60230 CHAMBLY sales.fr@avire-global.com France www.memco-global.com Memco is a brand of Avire www.avire-global.com...
  • Page 7 Utilizzando una connessione a due fili, possono essere collegate fino a 3 unità MPS all’unità centrale Memcom e saranno alimentati dalla batteria integrata Memcom. Altre stazioni possono essere aggiunte, ma dovranno essere potenziato collegando un alimentatore a 24 V DC a ogni stazione aggiunta. Blocco connettori di collegamento Unità MPS (492 021) collegate in parallelo/serie...
  • Page 8: Regolazione Volume

    Led Rosso brillante - Allarme attivato Fissaggio dell’unità L’unità può essere fissata utilizzando le viti autofilettanti M4.2 fornite in dotazione. Avire Ltd Via C. Goldoni, 1 +39 02 76014334 20129 Milano sales.it@avire-global.com ITALIA www.memco-global.com Memco is a brand of Avire www.avire-global.com...
  • Page 9 Hasta 3 unidades MPS el propio teléfono Memcom las alimenta gracias a su batería integrada. A partir de la cuarta MPS, cada estación MPS necesitará alimentación adicional de 24VDC. Bloque conector del Memcom Estaciones MPS (492 021) conectadas en paralelo o en serie...
  • Page 10: Ajustar El Volumen

    M4.2. La unidad se puede colgar y descolgar sin necesidad de desatornillarla, deslizándola lateralmente. Avire Ltd Edificio ROZAS NOVA - Of.127 +34 91 636 35 02 C/ Castillo de Fuensaldaña, 4 +34 91 637 39 06 28232 Las Rozas, Madrid, sales.es@avire-global.com ESPAÑA www.memco-global.com Memco is a brand of Avire www.avire-global.com...

Table of Contents