7. Cleaning
Clean the NHX stations with a soft cloth dampened with neutral household cleanser.
Never use any abrasive cleaner or cloth.
8. Markings
In accordance with CSA C22.2 No.125-M1984, the 4th Edition Standard For Electromedical Equipment the following
NHX Series units are provided with the "Risk Class 1 Part" (and in French-"Risque La Pièce Clàss 1") marking.
Model: NH-1SA, NH-2SA, -1SA/A, -2SA/A Patient Stations;
Model NHR-7A Bath Pull-Cord Stations;
Model NHR-8A Call Cord.

SPECIFICATIONS

• Power source:
• Power supply:
• Station capacity:
• Communication:
• Call-ins:
• Priority:
• Warning tone:
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules.
These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment
generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause
harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If
this equipment does cause harmful inteference to radio or television reception, which can be determined by turning the equipment off and on,
the user is encouraged to try to correct the interference by one or more of the following measures:
• Reorient or relocate the receiving antenna.
connected • Increase the separation between the equipment and receiver.
help.
Aiphone warrants its products to be free from defects of material and workmanship under normal use and service for a period of one year
after delivery to the ultimate user and will repair free of charge or replace at no charge, should it become defective upon which examination
shall disclose to be defective and under warranty. Aiphone reserves unto itself the sole right to make the final decision whether there is a
defect in materials and/or workmanship; and whether or not the product is within the warranty.
This warranty shall not apply to any Aiphone product which has been subject to misuse, neglect, accident, or to use in violation of
instructions furnished, nor extended to units which have been repaired or altered outside of the factory. This warranty does not cover
batteries or damage caused by batteries used in connection with the product.
This warranty covers bench repairs only, and any repairs must be made at the shop or place designated in writing by Aiphone.
Aiphone will not be responsible for any costs incurred involving on site service calls.
AIPHONE CO., LTD., NAGOYA, JAPAN
AIPHONE CORPORATION, BELLEVUE, WA, USA
AIPHONE EUROPE N.V., ANTWERP, BELGIUM
NHX-80X: DC 24V. 4A (max.).
Two PS-24E or PS-2420 power supplies are connected to NHX-80X CCU.
50 bedside sub stations, including bathroom call sub stations (NHR-3TS).
Expandable to 80 sub stations. Install the NHR-30K Expansion Card
and add NHX-30G to the NHX-50M.
Handset voice-actuation or press-to-talk communication at NHX-50M
master (on single and non-open channel). Hands free at bedside sub stations.
1. Routine call from bedside sub station.
2. Bathroom call (urgent) with pullcord.
3. Cord-out trouble call at bedside sub.
4. Common area urgent bathroom call
5. Hallway urgent staff call
In the order of time of call and urgency level;
Up to 5 calls displayed. At the end of each call, the next call is
automatically connected.
Line-off trouble (See Technical Precautions section).
Off-hook alarm after the handset is off-hook for 90 seconds with no communication
established.
• Connect the equipment into an outlet on a circuit different from that to which the receiver is
• Consult the dealer or an experienced radio/TV technician for
WARRANTY
– 12 –
http://www.aiphone.com/
Printed in Japan(E)