BandRich BandLuxe M280 Series Manual

Module datasheet
Table of Contents

Advertisement

Quick Links

®
BandLuxe
M280 Series HSUPA Module Datasheet
®
BandLuxe
M280 Series HSUPA Module Datasheet
(3.3V standard version)
1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the BandLuxe M280 Series and is the answer not in the manual?

Questions and answers

Summary of Contents for BandRich BandLuxe M280 Series

  • Page 1 ® BandLuxe M280 Series HSUPA Module Datasheet ® BandLuxe M280 Series HSUPA Module Datasheet (3.3V standard version)
  • Page 2 ARISING OUT OF THE USE OR INABILITY TO USE THIS MANUAL, EVEN IF PRODUCT OR ITS SUPPLIERS HAVE BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. BandRich M280 Datasheet Document Number: M280-D-001 BandRich Inc. 8F., No. 188, Baociao Rd., Sindian City TAIPEI, TAIWAN, R.O.C. http://www.bandrich.com COPYRIGHT ©2007-2008 BandRich All rights reserved.
  • Page 3: Revision History

    ® BandLuxe M280 Series HSUPA Module Datasheet Revision History Revision Date Description 2010-02-25 Draft Document Creation...
  • Page 4: Table Of Contents

    ® BandLuxe M280 Series HSUPA Module Datasheet Table of Contents Introduction ......................7 Section 1 General Description ....................7 Features......................... 8 WCDMA......................8 1.2.1 E-GPRS ......................8 1.2.2 Baseband Functionality................8 1.2.3 Software Functionality .................. 8 1.2.4 Interface Description....................9 Section 2 M280 Block Diagram ....................
  • Page 5 ® BandLuxe M280 Series HSUPA Module Datasheet List of Figures Figure 1-1 Top View..............................7 Figure 1-2 Bottom View............................7 Figure 2-1 M280 Block Diagram ..........................9 Figure 2-2 USB Interface ............................14 Figure 2-3 USIM Circuits Reference........................15 Figure 2-4 System Sleep Mode On/Off Level-Trigger ..................16 Figure 2-5 Module Reset ............................16 Figure 2-6...
  • Page 6 ® BandLuxe M280 Series HSUPA Module Datasheet List of Tables Table 1-1 Firmware Version Information ......................... 8 Table 2-1 M280 Module Series Connector Pin-out ....................... 10 Table 2-2 System Interface Signals ..........................11 Table 2-3 LED Output..............................13 Table 2-4 SIM Card Pin Definition ..........................
  • Page 7: Introduction

    ® BandLuxe M280 Series HSUPA Module Datasheet Section 1 Introduction General Description The M280 module series is PCI Express Mini Card providing WWAN (HSUPA, HSDPA, WCDMA, EGPRS) connectivity to laptops or any other device equipped with a PCI Express Mini Card slot. Figure 1-1 Top View Figure 1-2...
  • Page 8: Features

    USB2.0 interface, USIM interface, LED control signal, Wake# signal to request host device return from sleep/suspended state, and W_Disable# signal to disable radio operation. There are several GPIO pins (2.6V compatible) reserved for customized applications, please contact BandRich for discussion. Besides the above mentioned interfaces, M280V also provides PCM interfaces reserved for voice applications.
  • Page 9: Interface Description

    ® BandLuxe M280 Series HSUPA Module Datasheet Section 2 Interface Description M280 Block Diagram Figure 2-1 M280 Block Diagram...
  • Page 10: M280 Pci-Express Mini Card Interface

    ® BandLuxe M280 Series HSUPA Module Datasheet M280 PCI-Express Mini Card Interface 2.2.1 Pin Description Table 2-1 M280 Module Series Connector Pin-out Pin No. Name Pin No. Name WAKE# N.C. N.C. N.C. N.C. UIM_PWR UIM_DATA N.C. UIM_CLK N.C. UIM_RESET UIM_VPP(Optional) Mechanical Key N.C.
  • Page 11: System Interface Signals

    ® BandLuxe M280 Series HSUPA Module Datasheet 2.2.2 System Interface Signals Table 2-2 summarizes the signal and power lines that are supported by the system interface. Table 2-2 System Interface Signals Signal Group Signal Direction Description Pin Number Vcc ( 4pins) Power source 2, 39, 41, 52 4, 9, 15, 21, 26,...
  • Page 12: Power Source And Ground

    ® BandLuxe M280 Series HSUPA Module Datasheet Signal Group Signal Direction Description Pin Number PCM data output for auxiliary codec PCM_DOUT Output (M280V only) port PCM data input for auxiliary codec PCM_DIN Input port PCM data strobe for auxiliary codec PCM_SYNC Output port...
  • Page 13: Network Led Indicate Device

    ® BandLuxe M280 Series HSUPA Module Datasheet Network LED indicator (optional) The Network LED indicated device is ground-referenced current sink. The host drives the device to provide a current path and an appropriate voltage for LED for M280 module. Table 2-3 describes the LED output characteristics in different states.
  • Page 14: Usb Interface

    ® BandLuxe M280 Series HSUPA Module Datasheet USB Interface M280 and M280V module are compliant with USB2.0 in all three modes (Low speed, Full speed, and high speed). When two devices are connected via a USB interface, one of the devices must act as a host, and the other device must act as a peripheral.
  • Page 15: Auxiliary Signals Interface

    ® BandLuxe M280 Series HSUPA Module Datasheet ó USIM_CLK and USIM_RST signal, include 33pF filter capacitors is required to be placed near the SIM connector. ó Route all USIM signals carefully – isolate them from sensitive analog and RF signals. ó...
  • Page 16: Perst

    ® BandLuxe M280 Series HSUPA Module Datasheet system (Figure 2-4), the module shall disable radio operation. All transients resulting from mechanical switches need to be de-bounced by host system circuitry. In normal operation, the module will disassociate with the wireless network and cease any further operations (transmit/receive) as soon as possible after the W_DISABLE# signal is asserted.
  • Page 17: Antenna Guidelines And Rf Connection

    ® BandLuxe M280 Series HSUPA Module Datasheet Antenna Guidelines and RF Connection This section describes general guidelines for the design of multi-band antenna required for the M280 module series. 2.7.1 Antenna specifications Frequency range ó GSM850 (824-894 MHz) ó EGSM900 (880-960 MHz) ó...
  • Page 18: Pcm Interface

    ® BandLuxe M280 Series HSUPA Module Datasheet 2.7.3 Antenna connector The antenna connector type used is a U.FL microwave coaxial connector. It is also can be used for testing purpose. Figure 2-6 Antenna Connector Position and Type Diversity Antenna Main Antenna Connector Connector PCM Interface...
  • Page 19: Device Driver Interface

    ® BandLuxe M280 Series HSUPA Module Datasheet Section 3 Device Driver Interface Basically the module will manifest itself as a composite USB device which creates stubs which the other higher level drivers hook into and provide their respective function. The composite USB device could be modem, NDIS interface, AT command interface or diagnostics interface.
  • Page 20 ® BandLuxe M280 Series HSUPA Module Datasheet This page is leave in blank for note or memo use...
  • Page 21: At Command Set Reference

    ® BandLuxe M280 Series HSUPA Module Datasheet Section 4 AT Command Set Reference For the description of BandLuxe AT Command API, please refer to Appendix B for reference. For the description of BandLuxe proprietary AT Command API, please refer to Appendix C for reference.
  • Page 22 ® BandLuxe M280 Series HSUPA Module Datasheet This page is leave in blank for note or memo use...
  • Page 23: Physical Characteristics

    ® BandLuxe M280 Series HSUPA Module Datasheet Section 5 Physical Characteristics Dimensions Table 5-1 M280 Dimensions Length 26.8 mm Width 30 mm Dimensions Thickness 4.25 mm Weight Approx 10 g Figure 5-1 M280 Dimensioned View...
  • Page 24 ® BandLuxe M280 Series HSUPA Module Datasheet...
  • Page 25: Dc Electrical Specification

    ® BandLuxe M280 Series HSUPA Module Datasheet DC Electrical Specification 5.2.1 Absolute Maximum Ratings Operating M280 module under conditions that exceed those listed in Table 5-3 result in damage to the device. Absolute maximum ratings are limiting values, and are considered individually, while all other parameters are within their specified operating ranges.
  • Page 26: Dc Characteristics

    ® BandLuxe M280 Series HSUPA Module Datasheet 5.2.3 DC Characteristics Table 5-4 DC Characteristics, Vdd=2.6V Parameter Symbol Min. Max. Units High-level input voltage, V_IH 0.65xVdd Vdd+0.3 Volts CMOS/Schmitt Low-level input voltage, V_IL -0.3 0.35xVdd Volts CMOS/Schmitt Schmitt hysteresis voltage V_SHYS Input high leakage current I_IH —...
  • Page 27: Rf System Specification

    ® BandLuxe M280 Series HSUPA Module Datasheet RF System Specification The RF performance is compliant with 3GPP Mobile Station Minimum Performance specifications. Please refer to those documents for detailed specifications and test methods. The typical values of maximum transmit power and receiver sensitivity at different modes is listed below. 5.3.1 WCDMA Power Table 5-5...
  • Page 28: Thermal Dissipation

    ® BandLuxe M280 Series HSUPA Module Datasheet 5.3.4 Power Consumption Table 5-8 M280 Power Consumption M280 Test Condition (Average) Flying Mode 80 mA Flying Mode with suspend power saving 3.4 mA Sleep Mode 1.5 mA Idle Mode 84 mA Idle Mode with suspend power saving (USB ON) 13 mA HSDPA 7.2Mbps/384Kbp (Max.
  • Page 29: Packing Information

    ® BandLuxe M280 Series HSUPA Module Datasheet Section 6 Packing Information For the information about packing of shipment, packing material, and storage environment recommendation, please refers to “BandLuxe Module Packing and Storage Recommendation”.
  • Page 30 ® BandLuxe M280 Series HSUPA Module Datasheet This page is leave in blank for note or memo use...
  • Page 31: Appendix A Abbreviations And Acronyms

    ® BandLuxe M280 Series HSUPA Module Datasheet Appendix A Abbreviations and Acronyms The abbreviations and acronyms used in this document. Table A-1 Abbreviations and Acronyms Table Abbreviations Full Name Accumulated Call Meter American Standard Code for Information Interchange ASCII Attention commands Cell Broadcast Cell Broadcasting Service Call Control Meter...
  • Page 32 ® BandLuxe M280 Series HSUPA Module Datasheet Abbreviations Full Name Mobile Terminated Other Equipment Manufacturer Phone Book Protocol Data Unit Packet Handler Personal Identity Number Public Land Mobile Network PLMN Price per Unit Currency Table PUCT PIN Unblocking Code Random Access Channel RACH Radio Link Protocol Root Mean Square...
  • Page 33: Appendix B Bandluxe At Command Api

    ® BandLuxe M280 Series HSUPA Module Datasheet Appendix B BandLuxe AT Command API Appendix B lists the standard AT command that are implemented in BandLuxe M280 module series. For detail command usage and possible response, please check 3GPP TS 27.007, AT command set for User Equipment (UE).
  • Page 34 ® BandLuxe M280 Series HSUPA Module Datasheet AT Command Command description Command Format AT+CFUN Full functionality mode AT+CFUN=<mode>[,<rst>] AT+CFUN? AT+CFUN=? AT+GCAP Request complete TA capabilities AT+GCAP list AT+GCAP=? AT+CSCS Used Character Set AT+CSCS=[<chset>] AT+CSCS? AT+CSCS=? AT+CEER Cause Location ID for the extended AT+CEER error report AT+CMEE...
  • Page 35 ® BandLuxe M280 Series HSUPA Module Datasheet AT Command Command description Command Format AT+CGEQMIN 3G Quality of Service Profile AT+CGEQMIN=[<cid> [,<Traffic class> (Minimum acceptable) [,<Maximum bitrate UL> [,<Maximum bitrate DL> [,<Guaranteed bitrate UL> [,<Guaranteed bitrate DL> [,<Delivery order> [,<Maximum SDU size> [,<SDU error ratio>...
  • Page 36 ® BandLuxe M280 Series HSUPA Module Datasheet AT Command Command description Command Format AT+CSQ Request signal strength AT+CSQ AT+CSQ=? AT+CPIN Check PIN Status AT+CPIN=<pin>[,<newpin>] AT+CPIN? AT+CPIN=? AT+CGATT PS attach / detach AT+CGATT= [<state>] AT+CGATT? AT+CGATT=? AT+CGACT PDP context activate or deactivate AT+CGACT=[<state> [,<cid>[,<cid>[,…]]]] AT+CGACT? AT+CGACT=? AT+CGCMOD...
  • Page 37 ® BandLuxe M280 Series HSUPA Module Datasheet AT Command Command description Command Format AT+CPWD Change password AT+CPWD=<fac>,<oldpwd>,<newpwd> AT+CPWD=? AT+CUSD Unstructured supplementary AT+CUSD=[<n>[,<str>[,<dcs>]]] service data AT+CUSD? AT+CUSD=? AT+CIMI Read IMSI AT+CIMI AT+CIMI=? AT+CGMI Request manufacturer identification AT+CGMI AT+CGMM Request model identification AT+CGMM AT+CGMR Request revision identification...
  • Page 38: Appendix C Bandluxe Proprietary At Command Api

    ® BandLuxe M280 Series HSUPA Module Datasheet Appendix C BandLuxe Proprietary AT Command API Appendix C lists the BandLuxe proprietary AT command that are implemented in BandLuxe M280 module series. AT$SYSMODE – Query current network type C.1.1 DESCRIPTION Query current network type C.1.2 SYNTAX Command...
  • Page 39 ® BandLuxe M280 Series HSUPA Module Datasheet AT$PREFNETTYPE – Set Prefer network type C.2.1 DESCRIPTION Set prefer network type C.2.2 SYNTAX Command Possible response(s) $PREFNETTYPE=<mode> $PREFNETTYPE? $PREFNETTYPE: <mode> $PREFNETTYPE=? $PREFNETTYPE: (0-4) C.2.3 PARAMETERS <mode> WCDMA only WCDMA first Automatic GSM first GSM only C.2.4 Examples...
  • Page 40: Appendix D Call Related Standard At Command Api And

    ® BandLuxe M280 Series HSUPA Module Datasheet Appendix D Call Related Standard AT Command API and BandLuxe Proprietary AT Command API This Appendix list call related BandLuxe proprietary AT commands and examples of some call related standard AT commands implemented in M280V module. BandLuxe M280V module also provides unsolicited information of the call states for call management.
  • Page 41 ® BandLuxe M280 Series HSUPA Module Datasheet Originate a call : ATD<dialstring> ; D.2.1 DESCRIPTION Originate a call D.2.2 SYNTAX Command Possible response(s) D<dialstring> ; ERROR NO CARRIOR D.2.3 PARAMETERS <dialstring> Dailing string D.2.4 Examples test command example: ATD123; Answer a call : ATA D.3.1 DESCRIPTION Answer a call...
  • Page 42 ® BandLuxe M280 Series HSUPA Module Datasheet Call Mode +CMOD D.4.1 DESCRIPTION Set command selects the call mode of further dialing commands (D) or for next answering command (A). Mode can be either single or alternating (in the present document, terms "alternating mode" and "alternating call" refer to all GSM/UMTS bearer and teleservices that incorporate more than one basic service (voice, data, fax) within one call).
  • Page 43 ® BandLuxe M280 Series HSUPA Module Datasheet Hangup call : AT+CHUP D.5.1 DESCRIPTION Execution command causes the TA to hang up the current GSM/UMTS call of the MT. D.5.2 SYNTAX Command Possible response(s) +CHUP +CHUP= ? D.5.3 PARAMETERS NONE D.5.4 Examples test command example: AT+CHUP...
  • Page 44 ® BandLuxe M280 Series HSUPA Module Datasheet SYNC [,<priority>[,<subaddr>,<satype>]] synchronous transparent REL ASYNC [,<priority>[,<subaddr>,<satype>]] asynchronous non-transparent REL SYNC [,<priority>[,<subaddr>,<satype>]] synchronous non-transparent FAX [,<priority>[,<subaddr>,<satype>]] facsimile (TS 62) VOICE [,<priority>[,<subaddr>,<satype>]] normal voice (TS 11) VOICE/XXX [,<priority>[,<subaddr>,<satype>]] voice followed by data (BS 81) (XXX is ASYNC, SYNC, REL ASYNC or REL SYNC) ALT VOICE/XXX [,<priority>[,<subaddr>,<satype>]] alternating voice/data, voice first (BS 61) ALT XXX/VOICE [,<priority>[,<subaddr>,<satype>]] alternating voice/data, data first (BS 61) ALT...
  • Page 45 ® BandLuxe M280 Series HSUPA Module Datasheet conversation state. D.7.2 SYNTAX Command Possible response(s) +DTMF= <cid>, <key> +CME ERROR: <err> +DTMF=? D.7.3 PARAMETERS <cid>: integer type; call identification number as described in 3GPP TS 22.030 subclause 4.5.5.1. <key>: DTMF digit; the representing character key is listed in the following table. Char IRA(dec) 0…9...
  • Page 46 ® BandLuxe M280 Series HSUPA Module Datasheet D.8.3 PARAMETERS <reason>: 0 unconditional 1 mobile busy 2 no reply 3 not reachable 4 all call forwarding (refer 3GPP TS 22.030 [19]) 5 all conditional call forwarding (refer 3GPP TS 22.030 [19]) <mode>: 0 disable 1 enable...
  • Page 47 ® BandLuxe M280 Series HSUPA Module Datasheet Call waiting : AT+CCWA D.9.1 DESCRIPTION This command allows control of the Call Waiting supplementary service according to 3GPP TS 22.083. Activation, deactivation and status query are supported. When querying the status of a network service (<mode>=2) the response line for 'not active' case (<status>=0) should be returned only if service is not active for any <class>.
  • Page 48 ® BandLuxe M280 Series HSUPA Module Datasheet not be significant. Nevertheless, TA may return the recommended value 128 for <type> ((TON/NPI unknown in accordance with TS 24.008 subclause 10.5.4.7). When CLI has been withheld by the originator, (<CLI validity>=1) and the CLIP is provisioned with the "override category"...
  • Page 49 ® BandLuxe M280 Series HSUPA Module Datasheet D.10.2 SYNTAX Command Possible response(s) +CHLD=[<n] +CME ERROR: <err> +CHLD= ? [+CHLD: (list of supported <n>s)] D.10.3 PARAMETERS <n>: integer type; equals to numbers entered before SEND button in 3GPP TS 22.030 [19] subclause 4.5.5.1 NOTE: The "directory number"...
  • Page 50 ® BandLuxe M280 Series HSUPA Module Datasheet <stat> (state of the call): 0 active 1 held 2 dialing (MO call) 3 alerting (MO call) 4 incoming (MT call) 5 waiting (MT call) 6 disconnected <mode> (bearer/teleservice): 0 voice 1 data 2 fax 3 voice followed by data, voice mode 4 alternating voice/data, voice mode...
  • Page 51 ® BandLuxe M280 Series HSUPA Module Datasheet D.12.4 Enter PIN Code at+cpin="0000" D.12.5 PIN Code Disable at+clck="sc",0,"0000"...

Table of Contents