Weather X RPS8807DT Instruction Manual

Power generator
Hide thumbs Also See for RPS8807DT:

Advertisement

Power Generator
RPS8807DT

INSTRUCTION MANUAL

Advertisement

Table of Contents
loading

Summary of Contents for Weather X RPS8807DT

  • Page 1: Instruction Manual

    Power Generator RPS8807DT INSTRUCTION MANUAL...
  • Page 2: Warnings And Precautions

    Warnings and Precautions TO PREVENT FIRE OR SHOCK HAZARDS, DO NOT EXPOSE THIS UNIT TO RAIN OR MOISTURE. THE UNIT GENERATES THE SAME POTENTIALLY LETHAL AC POWER AS A NOR- MAL HOUSEHOLD WALL OUTLET. DO NOT INSERT FOREIGN OBJECTS INTO THE AC OUTLET, THE DC POWER SOCKET AND CABLE PORT, OR THE VENTILATION HOLES.
  • Page 3: Important Safety Instructions

    Important Safety Instructions 1. Read these instructions. 15. Only connect to the type of house-hold power supply as indicated in the operating instructions and 2. Keep these instructions. rating label. 3. Heed all warnings. 16. Do not overload wall outlets or extension cords as 4.
  • Page 4 AMG Battery Before being shipped, a safety key was placed in the bottom of the unit to disengage the sealed lead-acid battery for safety reasons, as well as to improve the longevity of the battery. To enable the battery for usage, simply pull this key out of the unit.
  • Page 5: Special Features

    Special Features Emergency On If the LAMP function switch is set to EMERGENCY and the unit is plugged into an AC Outlet, the unit will automatically detect a power outage and power on the unit’s lamp. Rechargeable Flashlight of the internal rechargeable NiMH Battery, or it will take 4-AA Rechargeable Alkaline Batteries.
  • Page 6 Features...
  • Page 7 Power Diagnostics Press the BATTERY LEVEL button to view the charge of the sealed lead acid battery. The Charge and AC Output indicators show the status of the battery. If the Charge indicator is red, unit is charging, and if it is green, the unit is fully charged. The AC Output indicator shows when the AC output is switched on.
  • Page 8 22 SNOOZE Press the SNOOZE button to delay ALARM 1 or ALARM 2 for 5 minutes after either one has sounded. 23 Thermometer Use the thermometer to view the temperature in Fahrenheit or Celsius. 24 Release 25 DC SOCKET (12V) Plug in to the DC 12V SOCKET using a car adapter to power external devices. 26 FM Antenna tion.
  • Page 9: Tuning The Radio

    Operations Setting the Clock & Alarms a. Press and hold the CLK ADJ button until the clock hour blinks b. Press Tune +/- to change the clock hour c. Press the CLK ADJ button d. Press Tune +/- to change the clock minute e.
  • Page 10 Operations Setting the 7-Channel Weatherband Radio a. Press the POWER button to power on the unit. • FM Radio, AM Radio, AUX, or WB Radio will appear on the LCD when the unit is powered on. b. Press the FUNCTION button and select Weatherband Radio. •...
  • Page 11: Using The Air Compressor

    Operations Using the Air Compressor c. Open the latch on the valve connector and place the valve connector securely on a valve stem, then close the latch. e. Once the Air Compressor Gauge reaches the appropriate psi, or lbs/in , turn the Air Compressor off and disconnect the valve connector.
  • Page 12 7-Channel Weatherband Codes 2-162.425MHz 4-162.475MHz 6-162.525MHz ALABAMA PRESCOTT .........7 FORT COLLINS ......5 ANNISTON ........3 SHOW LOW .......2 GLENWOOD SPRINGS ....6 AUBURN ........7 TUCSON ........2 GRAND JUNCTION ....1 BIRMINGHAM ......1 WINDOW ROCK .......1 GREELEY ........2 CULLMAN .........5 YUMA .........1 LA JUNTA ........6 DEMOPOLIS ......3 MEAD/LONGMOUNT ....3 DOZIER ........1...
  • Page 13 GEORGIA CONCORDIA ......1 TRAVERSE CITY.......2 ATHENS........2 DODGE CITY ......3 ATLANTA ........1 ELLSWORTH ......2 MINNESOTA AUGUSTA ........1 LENORA ........4 BEMIDJI ........4 BAXLEY ........7 TOPEKA ........3 DETROIT LAKES ......2 CHATSWORTH ......2 TRIBUNE........1 DULUTH ........1 COLUMBUS .......2 WICHITA ........1 INTERNATIONAL FALLS ..1 MACON ........3 MANKATO .........2 PELHAM ........1 KENTUCKY...
  • Page 14 MERRIMAN .......2 NORTH DAKOTA STATE COLLEGE ......3 NORFOLK ........1 BISMARCK ........3 TOWANDA .........1 NORTH PLATTE ......1 DEVILS LAKE ......4 WARREN ........5 DICKINSON .......2 OMAHA ........2 WELLSBORO ......3 SCOTTSBLUFF......1 FARGO ........3 WILKES-BARRE .......1 GRAND FORKS ......3 WILLIAMSPORT .......2 NEVADA JAMESTOWN ......1 MINOT ........2 ELKO ..........1 PUERTO RICO...
  • Page 15 LLANO ........4 WINDSOR ........3 HINTON ........4 LUBBOCK ........2 MOOREFIELD ......2 LUFKIN ........1 VIRGINIA SPENCER ........6 ODESSA/MIDLAND ....2 HEATHSVILLE ......2 SUTTON ........5 PARIS ..........1 LYNCHBURG ......1 PHARR........2 NORFOLK ........1 WISCONSIN SAN ANGELO ......1 RICHMOND .......3 ADAMS ........2 SAN ANTONIO ......1 ROANOKE .........3 GREENBAY ........1 SHERMAN .........3 LA CROSSE (P) ......1...
  • Page 16: Service Information

    Service Information Address Phone 1-314-621-2881 Email weatherxcustserv@weather-x.net Website www.weather-x.net To download this Instruction Man- Para descargar este manual de Pour télécharger manuel ual in English, Spanish, or French instrucción en inglés, español, o d’instruction en anglais, espagnol, visit the Support section at francés visite la sección de la ayu- ou le Français visitez la section de www.weather-x.net.

Table of Contents