De Die etrich G Gas 310 E Eco Ser ries Englis Loca al-Rem mote sw witch 10/28/09 ront view (switch inst talled) Swit tch Inst tallation n Manu Warn ning: Before you o operate this boile er, read this man nual carefully and d take extra preca...
Page 2
Warning failure to follow the instructions below could result in damage or unsafe operation of the boiler which will not be covered under warranty. Warning/Caution: Please follow instruction exactly, follow local/national equipment lockout procedures prior to proceeding with the installation of this option. If the boiler is in operation prior to the installation of this option, allow the boiler to cool down or force the boiler into cooling mode. Gas310 Local‐remote kit contents: item Description Mfr Part # Short handle selector switch PB22BSRS21K Label frame PALBF18 Plastic holder PBMBN Contact block [x2] NO PA2200/2 Red wire CSA TEW/UL 1015 18awg. (16std) WIR-TEW18/16RED ...
Page 3
Step‐By‐Step, installation procedure: STEP 1: 1. Shut‐off gas supply to boiler at the boiler gas supply shutoff manual valve. 2. Disconnect power at the fuse disconnect. 3. Remove boiler control cover (see fig. 1) and retain the cover screws. 4. Drill hole in front of boiler control cover (see fig. 2), a drilling template is provided with the kit ...
Hole location for switch R 0.435 In [11mm] Use 22mm or 7/8In hole saw 2.56 In. [65mm] Front view 1.38 In. [35mm] 5. Install and mount switch assembly components as shown (see fig. 3), confirm the correct position and orientation of the switch (see fig. 4a,b,c) Front view (switch installed) Switch Assembly Switch Position Remote/Local Remote Local [0-10v] ...
Page 5
6. Wire switch as shown (see fig. 5, if the enable‐disable function is not needed, do not wire the switch contact to terminals X29.5 & X29.6. the kit comes with (4) red wires pre‐cut and insulation removed for easy wiring. X29.9 & X29.10 terminal (optional) to disable 0-10v remote signal from BMS (BAS) to allow local boiler control operation. X29.5 & X29.6 terminal (optional) if BMS (BAS) using enable/disable required for local boiler control operation. If not used, bridge terminals (jumper) [x2] NO contact switch block ...
Page 6
7. Reinstall control cover (see fig 1) 8. Turn on the gas and restore the main power at the fuse disconnect 9. Turn on the boiler main switch 10. Configure the boiler control to allow 0‐10v remote signal based on temperature set‐point or output based, change the user setting parameter = local modulation from =0‐10v based on temperature from = 0‐10v based on boiler output 11. Verify correct boiler operation and shutdown of boiler according to remote set‐point and the local set‐point (see boiler I‐O manual for detailed instructions) a) In local mode (switch in local position) the setting shall be determined by parameter (XX is the setting programmed) note the decimal position if control has been setup for °F for °C the displayed values is a direct reading. b) In remote mode (switch in remote position) setting will be determined by the 0‐10v signal measured on X29.11 & X29.12. The actual voltage input can be observed in the read‐out mode, consult the boiler manual. Application note: The local setting parameter is the maximum Temperature V(dc) Output based Boiler temperature set‐point the boiler will supply regardless of (in) ...