DeDietrich Gas 310 Eco Series Installation Manual
DeDietrich Gas 310 Eco Series Installation Manual

DeDietrich Gas 310 Eco Series Installation Manual

Local-remote switch

Advertisement

Quick Links

De Die
etrich G
Gas 310 E
Loca
al-Rem
mote sw
 
 
 
Fr
ront view (switch inst
talled)
Warn
ning:
Before you o
operate this boile
er, read this man
items. The o
operating manua
l is part of the do
system and
boiler operating
instructions.
Notice
e:
Please read
d this manual an
d retain for futur
cause injury
y, loss of life or
property damag
installer, ser
rvice agency or t
he gas supplier.
 
Eco Ser
ries
witch
 
Swit
tch Inst
tallation
nual carefully and
d take extra preca
ocumentation alo
ong with the boile
re reference. Im
mproper installati
e. Refer to this
s manual for ass
 
n Manu
ual
autions to all saf
fety and warning
er. The installer is
s required to exp
on, adjustment,
alteration, servic
sistance or addit
tional information
     
 
Englis
sh
10/28/09
9
symbols or impo
ortant
plain your heating
g
ce or maintenan
nce can
n or consult a q
ualified

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Gas 310 Eco Series and is the answer not in the manual?

Questions and answers

Summary of Contents for DeDietrich Gas 310 Eco Series

  • Page 1 De Die etrich G Gas 310 E Eco Ser ries Englis Loca al-Rem mote sw witch   10/28/09       ront view (switch inst talled) Swit tch Inst tallation n Manu Warn ning: Before you o operate this boile er, read this man nual carefully and d take extra preca...
  • Page 2         Warning failure to follow the instructions below could result in damage or unsafe operation of the boiler  which will not be covered under warranty.   Warning/Caution:  Please follow instruction exactly, follow local/national equipment lockout procedures prior to  proceeding with the installation of this option.   If the boiler is in operation prior to the installation of this option, allow the boiler to cool down or force  the boiler into cooling mode.    Gas310 Local‐remote kit contents:    item Description Mfr Part #   Short handle selector switch PB22BSRS21K Label frame PALBF18   Plastic holder PBMBN Contact block [x2] NO PA2200/2   Red wire CSA TEW/UL 1015 18awg. (16std) WIR-TEW18/16RED  ...
  • Page 3 Step‐By‐Step, installation procedure:    STEP 1:    1. Shut‐off gas supply to boiler at the boiler gas supply shutoff manual valve. 2. Disconnect power at the fuse disconnect.   3. Remove boiler control cover (see fig. 1) and retain the cover screws.          4. Drill hole in front of boiler control cover (see fig. 2), a drilling template is provided with the kit    ...
  • Page 4: Front View

    Hole location for switch R 0.435 In [11mm] Use 22mm or 7/8In hole saw 2.56 In. [65mm] Front view 1.38 In. [35mm]   5. Install and mount switch assembly  components as shown (see fig. 3), confirm the correct  position and orientation of the switch (see fig. 4a,b,c)          Front view (switch installed) Switch Assembly Switch Position Remote/Local Remote Local [0-10v]  ...
  • Page 5 6. Wire switch as shown (see fig. 5, if the enable‐disable function is not needed, do not wire the  switch contact to terminals X29.5 & X29.6. the kit comes with (4) red wires pre‐cut and  insulation removed for easy wiring.  X29.9 & X29.10 terminal (optional) to disable 0-10v remote signal from BMS (BAS) to allow local boiler control operation. X29.5 & X29.6 terminal (optional) if BMS (BAS) using enable/disable required for local boiler control operation. If not used, bridge terminals (jumper) [x2] NO contact switch block  ...
  • Page 6 7. Reinstall control cover (see fig 1)    8. Turn on the gas and restore the main power at the fuse disconnect    9. Turn on the boiler main switch    10. Configure the boiler control to allow 0‐10v remote signal based on temperature set‐point or  output based, change the user setting parameter     = local modulation  from   =0‐10v based on temperature  from   = 0‐10v based on boiler output    11. Verify correct boiler operation and shutdown of boiler according to remote set‐point and the  local set‐point (see boiler I‐O manual for detailed instructions)    a) In local mode (switch in local position) the setting shall be determined by parameter   (XX is the setting programmed) note the decimal position if control has been  setup for °F for °C the displayed values is a direct reading.  b) In remote mode (switch in remote position) setting will be determined by the 0‐10v signal  measured on X29.11 & X29.12. The actual voltage input can be observed in the read‐out  mode, consult the boiler manual.  Application note:  The local setting parameter   is the maximum  Temperature  V(dc)  Output  based  Boiler  temperature set‐point the boiler will supply regardless of  (in) ...
  • Page 7      ...
  • Page 8   Bp 30 – 57, RUE DE LA Gare  F – 67580 MERTZWILLER  Tel: +33/3/88/80/27/00 – Fax: +33/3 88 80 27 99  Ni IRC : 347 555 559 RCS STRASBOURG Remeha B.V. Postbus 32 7300 AA APELDOORN, NL Tel: +31 55 5496969 Fax: +31 55 5496496 Internet: www.nl.remeha.com E-mail: remeha@remeha.com   www.dedietrich‐thermique.com         DDR AMERICAS INC .  In Canada:  In USA or South America:  1090 Fountain St., Unit #10  1054 North DuPage Avenue  Cambridge, Ontario, N3E 1A3 ‐ CANADA  Lombard, Illinois, USA 60148  Tel: 519.650.0420 Fax: 519.650.1709  Tel: 630.953.2374 Fax: 630.953.2376 ...