Advertisement

Quick Links

Infinitybox™ 10 and 20-Circuit Kit

Table of Contents

Warnings ....................................................................................................................................................... 2
Installation Steps ........................................................................................................................................... 3
STEP 1: Mounting the Cells ....................................................................................................................... 4
STEP 2: Running Power from the Battery ................................................................................................. 7
STEP 3: Connecting the CAN Cable ........................................................................................................... 9
STEP 4: Wiring the POWERCELL Outputs ................................................................................................ 11
STEP 5: Wiring the Switches .................................................................................................................... 14
Checking CAN Communication .............................................................................................................. 16
STEP 6: Testing the System ..................................................................................................................... 16
Checking Switches ....................................................................................................................................... 17
Checking the Outputs ................................................................................................................................. 17
Warranty Information ................................................................................................................................. 18
Contact Information .................................................................................................................................... 19
Revision 20190416
Installation Guide
INFINITYBOX, LLC
599 North Edgewood Avenue
Wood Dale, Illinois 60191
www.infinitybox.com
1

Advertisement

Table of Contents
loading

Summary of Contents for Infinitybox 10-Circuit Kit

  • Page 1: Table Of Contents

    INFINITYBOX, LLC 599 North Edgewood Avenue Wood Dale, Illinois 60191 www.infinitybox.com Infinitybox™ 10 and 20-Circuit Kit Installation Guide Table of Contents Warnings ............................... 2 Installation Steps ............................3 STEP 1: Mounting the Cells ........................4 STEP 2: Running Power from the Battery ....................7 STEP 3: Connecting the CAN Cable ......................
  • Page 2: Warnings

    INFINITYBOX, LLC 599 North Edgewood Avenue Wood Dale, Illinois 60191 www.infinitybox.com Warnings INFINITYBOX SYSTEM IS AN ADVANCED ELECTRICAL POWER DISTRIBUTION MODULE FOR VEHICLES ROPER CARE MUST BE TAKEN TO FUSE THE INPUT FEEDS TO THE SYSTEM AND POWERCELL THE OUTPUT FEEDS FROM THE...
  • Page 3: Installation Steps

    Installation Steps ***STOP & READ CAREFULLY!*** You are about to wire your car with the Infinitybox system. There is no system on the market that is going to give you the power and flexibility that you can get with Infinitybox.
  • Page 4: Step 1: Mounting The Cells

    STEP 1: Mounting the Cells The Infinitybox system is a modular, multiplexed wiring system. This means that there are multiple remote cells that are mounted in the car where you need them. The MASTERCELL connects to your switches. You will mount that close to your switches.
  • Page 5 The address on the POWERCELL must be set to match the address defined in your configuration sheet. If you have a 10-Circuit Kit, your POWERCELL will be set at address 1. If you have a 20-Circuit Kit, the front POWERCELL address must be set as 1. The rear POWERCELL must be set as 2.
  • Page 6 INFINITYBOX, LLC 599 North Edgewood Avenue Wood Dale, Illinois 60191 www.infinitybox.com This picture shows how to properly orient the jumpers on the headers to set the cell address. Check List for Step 1- Mounting the Cells Did you consider the best locations for your cells considering troubleshooting, replacing...
  • Page 7: Step 2: Running Power From The Battery

    INFINITYBOX, LLC 599 North Edgewood Avenue Wood Dale, Illinois 60191 www.infinitybox.com STEP 2: Running Power from the Battery Each POWERCELL needs to connect directly to the positive terminal on your battery. This is where the POWERCELL gets the power needed to control the switched loads in the car.
  • Page 8 Wood Dale, Illinois 60191 www.infinitybox.com NOTE: A battery disconnect is strongly recommended with the Infinitybox system. You are adding a very sophisticated electrical system to your vehicle. We do what we can to minimize the amount of steady-state draw but there will always be a small drain on the battery when the vehicle is sitting idle.
  • Page 9: Step 3: Connecting The Can Cable

    CAN cables into either port. If you have a 10-Circuit Kit, you have a 2-way CAN cable. The cable has a CAN connector on each end. You plug one end of this cable into the CAN port on the MASTERCELL. The second end of the cable plugs into one of the open CAN ports on your POWERCELL.
  • Page 10 INFINITYBOX, LLC 599 North Edgewood Avenue Wood Dale, Illinois 60191 www.infinitybox.com MASTERCELL POWERCELL POWERCELL POWERCELL POWERCELL MASTERCELL = Cut red and black wires in this leg If you have your MASTERCELL on one end of the cable with a POWERCELL in the middle and one POWERCELL at the other end, you must cut the red and black wires between the two POWERCELLs.
  • Page 11: Step 4: Wiring The Powercell Outputs

    INFINITYBOX, LLC 599 North Edgewood Avenue Wood Dale, Illinois 60191 www.infinitybox.com STEP 4: Wiring the POWERCELL Outputs Consider each POWERCELL as a fuse and relay box. It gets power from the battery and commands from the MASTERCELL. It supplies battery power to a load in your vehicle when you turn on a switch connected to the MASTERCELL.
  • Page 12 INFINITYBOX, LLC 599 North Edgewood Avenue Wood Dale, Illinois 60191 www.infinitybox.com These tables summarize the wire colors for the A & B Output Harnesses. POWERCELL A Connector Pinouts Cavity Function Reference Wire Color Identification Ground Black Output 10 Output 9...
  • Page 13 INFINITYBOX, LLC 599 North Edgewood Avenue Wood Dale, Illinois 60191 www.infinitybox.com There is a fuse holder for each output wire on the POWERCELL located under the clear cover. This fuse is designed to protect the wire in case it gets accidentally shorted to ground.
  • Page 14: Step 5: Wiring The Switches

    We also have a large catalogue of switch examples on our website. Look for the Resources section at www.infinitybox.com. Revision 20190416...
  • Page 15 INFINITYBOX, LLC 599 North Edgewood Avenue Wood Dale, Illinois 60191 www.infinitybox.com Check List for STEP 5: Wiring the Switches Did you follow the wire colors on the configuration sheet that came with your kit? Did you make sure that your switches are wired so that no battery voltage can be...
  • Page 16: Step 6: Testing The System

    INFINITYBOX, LLC 599 North Edgewood Avenue Wood Dale, Illinois 60191 www.infinitybox.com STEP 6: Testing the System Once the hardware is properly set up, connect +12 volts through the input harnesses to the POWERCELLs. After 3 seconds, the system will be running and ready to test.
  • Page 17: Checking Switches

    Use your configuration sheet to verify that the correct output numbers are tuning on with your switch. If you have diagnostic or troubleshooting questions, download the Infinitybox Diagnostic and Troubleshooting Guide from the Resources section at www.infinitybox.com.
  • Page 18: Warranty Information

    United States. In order to receive warranty service, purchaser must provide Infinitybox with a copy of the receipt stating the dealer name, product purchased and date of purchase. Products found to be defective during the warranty period will be replaced (with a product deemed to be equivalent or better) at the discretion of Infinitybox.
  • Page 19: Contact Information

    INFINITYBOX, LLC 599 North Edgewood Avenue Wood Dale, Illinois 60191 www.infinitybox.com Contact Information The INFINITYBOX™ Intelligent Multiplex System is a product of Infinitybox, LLC 599 North Edgewood Avenue Wood Dale, Illinois 60191 (847) 232-1991 sales@infinitybox.com www.infinitybox.com Revision 20190416...