Page 1
EX-TECH-SIG-SAS-12-SD125-150-TM-EN-REV04 PRODUCT NAME: SD125-150, EXPLOSION-PROOFSOUNDER/HORN DOC NO.: EX-TECH-SIG-SAS-12-SD125-150-TM-EN-REV04 EXPLOSION PROOF SOUNDER/HORN II 2GD EPL Gb, Db Exd IIC T4/T5/T6 Gb, IP66 Ex tb IIIC Txxx EX-TECH SIGNALLING SAS SD125-150 EXPLOSION PROOF SOUNDER/HORN TECHNICAL MANUAL Marking details; Please note that every care has been taken to ensure the accuracy of our technical manual. We do not, however, accept responsibility for damage, loss or expense resulting from any error or omission.
Page 2
EX-TECH-SIG-SAS-12-SD125-150-TM-EN-REV04 TYPE APPROVAL STANDARD INTRODUCTION The BC series products have been approved according the SD-150/125 series Explosion-proof Sounder/Horn & following standards: Loudspeaker designed according EN / IEC 60079-0, EN / IEC 60079-1 and EN 54 (SB 5879) IEC/EN 60079 General Requirements standard.
Page 3
General Requirement PCB WIRING TERMINALS EX-TECH SIGNALLING SAS recommends that all cables and Apply power supply to up to 48V DC o r 100-250V AC to ‘L’ & cores should be fully identified (suggest using cable from 2.0 to 2.5 ‘N’...
Page 4
L N S0 S1 S2 DIY sound sound In order to have the option function, please inform EX- TECH SIGNALLING SAS in advance before EX-TECH SIGNALLING SAS begin the production of the sounder. Fig 3 11.0 CABLE GLAND SAFETY WARNING: If the SD150 is used at high ambient 8.0 VOLUME CONTROL...
If spare compliance with the structural specifications provided by parts are required, these can be supplied by EX-TECH the manufacturer. Repairs must not be made on the basis SIGNALLING SAS Company.
Page 6
EX-TECH-SIG-SAS-12-SD125-150-TM-EN-REV04 Attached Table 2: Tone Selection Table...
Page 7
EX-TECH-SIG-SAS-12-SD125-150-TM-EN-REV04 EX-TECH SIGNALLING SAS ZA Les Montagnes 355 rue de la Génoise 16430 CHAMPNIERS (France) Tel: +33 5 45 61 81 68 Fax: +33 5 45 23 29 46 Website: www.ex-tech.no E-mail: sales.signalling@ex-tech.no...
Page 8
Update le 01/07/2015 DESCRIPTION COMSUPTION ITEM SW1, SW2, SW3, SW4 Tone Frequency Tone Description Tone Application Waveform dB@1meter Bit 123456 DC (mA) AC (mA) 000000 300Hz Continuious 100000 340Hz Continuious 010000 440Hz Continuious 110000 554Hz Continuious 001000 660Hz Continuious All‐clear, Sweden 101000 800Hz Continuious 011000 1000Hz Continuious PFEER Toxic Gas 111000 1200Hz Continuious 000100 2000Hz Continuious...
Page 9
Wiring Method Factory default settings 1. S0 and S1 are connected (default stage 1 alarm output). 2. Connect power supply line to terminals "L" and "N". If power supply is DC. "L" presents "+". "N" presents "0". 3. The unit will alarm (default stage 1 alarm output) when power is on.
Page 10
Wiring Method Factory default settings 1. S0 and S1 are connected (default stage 1 alarm output). 2. Connect power supply line to terminals "L" and "N". If power supply is DC. "L" presents "+". "N" presents "0". 3. The unit will alarm (default stage 1 alarm output) when power is on.