Fluidwell F126-P-EL-TP Operation Manual

Flowcomputer with corrected liquid volume, signal input flowmeter: pulse, namur and coil, signal outputs: 4-20ma ref. flowrate and pulse ref. total, options: intrinsically safe, modbus communication, external reset
Hide thumbs Also See for F126-P-EL-TP:

Advertisement

Quick Links

F126-P-EL-TP
FLOWCOMPUTER WITH CORRECTED LIQUID VOLUME
Signal input flowmeter: pulse, Namur and coil
Signal outputs: 4-20mA ref. flowrate and pulse ref. total
Options: Intrinsically Safe, Modbus communication, external reset
F-Series - Field mounted indicators for safe and hazardous areas. More info: www.fluidwell.com/fseries

Advertisement

Table of Contents
loading

Summary of Contents for Fluidwell F126-P-EL-TP

  • Page 1 FLOWCOMPUTER WITH CORRECTED LIQUID VOLUME Signal input flowmeter: pulse, Namur and coil Signal outputs: 4-20mA ref. flowrate and pulse ref. total Options: Intrinsically Safe, Modbus communication, external reset F-Series - Field mounted indicators for safe and hazardous areas. More info: www.fluidwell.com/fseries...
  • Page 2: Safety Instructions

     Intrinsically Safe applications: follow the instructions as mentioned in Chapter 5 and consult “Fluidwell F1..-..-XI - Documentation for Intrinsic Safety”. DISPOSAL  At the end of its life this product should be disposed of according to local regulations regarding waste electronic equipment.
  • Page 3: About The Operation Manual

    Manual HF126PEN_EL_TP_v0501_07 © Copyright 2014 Fluidwell bv - The Netherlands. Information in this manual is subject to change without prior notice. The manufacturer is not responsible for mistakes in this material or for incidental damage caused as a direct or indirect result of the delivery, performance or use of this material.
  • Page 4: Table Of Contents

    Page 4 CONTENTS MANUAL Safety instructions ............................2 Disposal ..............................2 Safety rules and precautionary measures ....................... 2 About the operation manual ..........................3 Contents manual .............................. 4 Introduction ..........................5 1.1. System description of the F126-P-EL ..................5 Operational ..........................7 2.1.
  • Page 5: Introduction

    Page 5 INTRODUCTION 1.1. SYSTEM DESCRIPTION OF THE F126-P-EL Functions and features The flowcomputer Model F126-P-EL is a microprocessor driven instrument for the calculation of standard volumetric flow or mass flow for liquid applications using flow equations. This product has been designed with a focus on: ...
  • Page 6 Page 6 Configuration of the unit The F126-P-EL was designed to be implemented in many types of applications. For that reason, a SETUP-level is available to configure your F126-P-EL according to your specific requirements. SETUP includes several important features, such as K-factors, Span, measurement units, signal selection etc.
  • Page 7: Operational

    Page 7 OPERATIONAL 2.1. GENERAL  The F126-P-EL may only be operated by personnel who are authorized and trained by the operator of the facility. All instructions in this manual are to be observed.  Take careful notice of the " Safety rules, instructions and precautionary measures " in the front of this manual.
  • Page 8: Operator Information And Functions

    Page 8 2.3. OPERATOR INFORMATION AND FUNCTIONS In general, the F126-P-EL will always function at Operator level. The information displayed is dependant upon the SETUP-settings. All pulses generated by the connected flowmeter are measured by the F126-P-EL in the background, whichever screen refresh rate setting is chosen. After pressing a key, the display will be updated very quickly during a 30 second period, after which it will slow-down again.
  • Page 9: Configuration

    Page 9 CONFIGURATION 3.1. INTRODUCTION This and the following chapters are exclusively meant for electricians and non-operators. In these, an extensive description of all software settings and hardware connections are provided.  Mounting, electrical installation, start-up and maintenance of the instrument may only be carried out by trained personnel authorized by the operator of the facility.
  • Page 10 Page 10 Matrix structure SETUP-level: SCROLLING THROUGH SETUP-LEVEL Selection of function-group and function: SETUP is divided into several function groups and functions. Each function has a unique number, which is displayed below the word "SETUP" at the bottom of the display. The number is a combination of two figures. The first figure indicates the function-group and the second figure the sub-function.
  • Page 11 Page 11 To change or select a value: To change a value, use  to select the digits and  to increase that value. To select a setting, both  and  can be used. If the new value is invalid, the increase sign or decrease-sign will be displayed while you are programming.
  • Page 12: Overview Functions Setup Level

    Page 12 3.2.2. OVERVIEW FUNCTIONS SETUP LEVEL SETUP FUNCTIONS AND VARIABLES TOTAL UNIT L - m3 - kg - lb - GAL - USGAL - bbl - no unit DECIMALS 0 - 1 - 2 - 3 (Ref: displayed value) K-FACTOR: 0.000010 - 9,999,999 DECIMALS K-FACTOR...
  • Page 13: Explanation Of Setup-Functions

    Page 13 3.2.3. EXPLANATION OF SETUP-FUNCTIONS 1 - TOTAL SETUP - 11 determines the measurement unit for total, accumulated total MEASUREMENT UNIT and pulse output. The following units can be selected: L - m3 - kg - lb. - GAL - USGAL - bbl - _ (no unit). Alteration of the measurement unit will have consequences for operator and SETUP-level values.
  • Page 14: Flowrate

    Page 14 2 - FLOWRATE The settings for total and flowrate are entirely separate. In this way, different units of measurement can be used for each e.g. cubic meters for total and liters for flowrate. The display update time for flowrate is one second or more. Note: these settings also influence the analog output.
  • Page 15: Display

    Page 15 2 - FLOWRATE (CONTINUED) ILTER VALUE ESPONSE TIME ON STEP CHANGE OF ANALOG VALUE IME IN SECONDS INFLUENCE INFLUENCE INFLUENCE INFLUENCE 0.7 second 1.4 seconds 2.2 seconds 4.4 seconds 1.4 seconds 2.8 seconds 4.5 seconds 9.0 seconds 2.1 seconds 4 seconds 7 seconds 14 seconds...
  • Page 16: Flowmeter

    Page 16 5 - FLOWMETER The F126-P-EL is able to handle several types of input signal. The type of SIGNAL flowmeter pickup / signal is selected with function. Note: The selections "active pulse" offer a detection level of 50% of the supply voltage.
  • Page 17: Temperature

    Page 17 6 - TEMPERATURE Do select here the number of wires of the two PT100 elements - two or NO. OF WIRES three. The analog output signal of a sensor does mirror the actual temperature. FILTER This signal is measured several times a second. The value measured is a "snap-shot"...
  • Page 18: Analog Output

    Page 18 8 - ANALOG OUTPUT A linear analog (0)4-20mA or 0-10V signal is generated according to the flowrate with a 10 bits resolution. The settings for flowrate (SETUP - 2) influence the analog output directly. The relationship between rate and analog output is set with the following functions: The analog output can be disabled.
  • Page 19: Communication (Optional)

    Page 19 8 - ANALOG OUTPUT (CONTINUED) This function is used to stabilize the analog output signal. FILTER The output value is updated every 0.1 second. With the help of this digital filter a more stable but less precise reading can be obtained. The filter principal is based on three input values: the filter level (01-99), the last analog output value and the last average value.
  • Page 20: Installation

    Page 20 INSTALLATION 4.1. GENERAL DIRECTIONS  Mounting, electrical installation, start-up and maintenance of this instrument may only be carried out by trained personnel authorized by the operator of the facility. Personnel must read and understand this Operating Manual before carrying out its instructions. ...
  • Page 21: Dimensions- Enclosure

    Page 21 4.3. DIMENSIONS- ENCLOSURE Aluminum enclosures: 75 mm (2.95") 112 mm (4.40") 130 mm (5.12") 12mm 12mm 30mm 30mm 24mm 24mm M20 x 1,5 6 x M12 36mm 36mm 30mm 30mm M16 x 1,5 M16 x 1,5 1/2"NPT M20 x 1,5 0.12"...
  • Page 22 Page 22 GRP enclosures: 75 mm (2.95") 112 mm (4.40") 130 mm (5.12") HK back box: (flat bottom) 75 mm (2.95") 118 mm (4.65”) 25mm 25mm D=20mm D=20mm 12mm 12mm 30mm 30mm 24mm 24mm D=12mm D=16mm D=16mm D=20mm 36mm 36mm 0.12”...
  • Page 23: Installing The Hardware

    Page 23 4.4. INSTALLING THE HARDWARE 4.4.1. INTRODUCTION  Electro static discharge does inflict irreparable damage to electronics! Before installing or opening the unit, the installer has to discharge himself by touching a well-grounded object.  This unit must be installed in accordance with the EMC guidelines (Electro Magnetic Compatibility).
  • Page 24: Voltage Selection Sensor Supply

    Page 24 4.4.2. VOLTAGE SELECTION SENSOR SUPPLY For Intrinsically Safe applications: read chapter 5. Type PB / PC / PX (AP) - battery powered and output loop-powered applications: Terminal 11 provides a limited supply voltage of 3.2 V DC (coil signals 1.2V) for the signal output of the flowmeter.
  • Page 25: Terminal Connectors

    PD / PF / PM TYPE PX TYPE P SIGNAL Fig. 9: Overview of terminal connectors standard configuration F126-P-EL-TP and options. REMARKS: TERMINAL CONNECTORS: Terminal GND- 01- 02: Power Supply - only available with type PD / PF or PM: erminal...
  • Page 26 Page 26 Terminal 07-08; basic POWER SUPPLY - type PX - output loop powered: Connect an external power supply of 8-30VDC to these terminals or a 4-20mA loop. Do connect the "-" to terminal 7 and the "+" to terminal 8. When power is applied to these terminals, the (optional) internal battery will be disabled / enabled automatically to extend the battery life time.
  • Page 27 Page 27 Type AI: An isolated 4-20mA signal proportional to the flowrate is available with this option. When the output is disabled, a 3.5mA signal will be generated on these terminals. Max. driving capacity 1000 Ohm @ 30VDC. This option can be used with a battery powered unit but the life time of the battery is about 2 -3 years.
  • Page 28 Page 28 Terminal 09-11; Flowmeter input: Three basic types of flowmeter signals can be connected to the unit: pulse, active pulse or sine- wave (coil). The screen of the signal wire must be connected to the common ground terminal 09 (unless earthed at the sensor itself).
  • Page 29 Page 29 Pulse-signal PNP / PNP-LP: The F126-P-EL is suitable for use with flowmeters which have a PNP output signal. 3.2V is offered on terminal 11 which has to be switched by the sensor to terminal 10 (SIGNAL). For a reliable pulse detection, the pulse amplitude has to go above 1.2V.
  • Page 30 Page 30 Reed-switch: The F126-P-EL is suitable for use with flowmeters which have a reed-switch. To avoid pulse bounce from the reed-switch, it is advised to select REED LP - low-pass filter (read par. 3.2.3.) NAMUR-signal: The F126-P-EL is suitable for flowmeters with an Namur signal. The standard F126-P-EL is not able to power the Namur sensor, as an external power supply for the sensor is required.
  • Page 31 Page 31 Terminal 26-31: type CB / CH / CI / CT - communication RS232 / RS485 / TTL (option)  Full serial communications and computer control in accordance with RS232 (length of cable max. 15 meters) or RS485 (length of cable max. 1200 meters) is possible. ...
  • Page 32: Intrinsically Safe Applications

    Please Note Certificates, safety values and declaration of compliance can be found in the document named:  “Fluidwell F1..-..-XI - Documentation for Intrinsic Safety”.  Special conditions for safe use mentioned in both the certificate and the installation instructions must be observed for the connection of power to both input and / or output circuits.
  • Page 33: Terminal Connectors Intrinsically Safe Applications

    Indicated labels on the back cover (below) and on the inside cover (right) show the type labels for intrinsically safe certified units. For details on usage see the separate “Fluidwell F1..-..-XI Documentation for Intrinsic Safety”. Serial number and year of production This information can be looked-up on the display: See setup function (par.
  • Page 34 Page 34 Explanation Intrinsically Safe options: Option AF - Intrinsically Safe floating 4-20mA analog output: A floating 4-20mA signal proportional to the flowrate is available with this option. When the output is disabled, a 3.5mA signal will be generated. Max. driving capacity 1000 Ohm @ 30V DC. Type PD - Intrinsically Safe power supply and sensor supply - Terminal GND- 01 and 11.
  • Page 35: Configuration Examples

    Page 35 CONFIGURATION EXAMPLES Configuration example IIB /IIIC F126-P-AF-CT-EL-(PC)-(PD)-TP-XI HAZARDOUS AREA SAFE AREA TERMINAL CONNECTORS F100-series Modbus communication type CT: TTL I.S. Certified  Isolator TTL to: = max. 30 V e.g. PC RS232 = max. 250 mA RS422 = max. 0.85 W +12V For example: Common ground...
  • Page 36 Page 36 Configuration example IIB/IIIC and IIC - F126-P-AF-(CT)-EL-PD-TP-XI HAZARDOUS AREA SAFE AREA TERMINAL CONNECTORS F100-series Modbus communication type CT: TTL Please note: communciation type CT is allowed in IIC applications. I.S. Certified  Isolator TTL to: = max. 30 V e.g.
  • Page 37: Battery Replacement Instructions

    Batteries for use in safe areas have no Ex label. DO NOT EXCHANGE: Using the wrong type of battery can pose a SERIOUS RISK.  For use in hazardous areas Fluidwell recommends FW-LiBAT batteries (manufactured by Fluidwell bv) only. Battery replacement procedure Depending on the production batch, one of two visualized Intrinsically Safe certified battery types may have been installed in the unit.
  • Page 38: Maintenance

    Page 38 MAINTENANCE 6.1. GENERAL DIRECTIONS  Mounting, electrical installation, start-up and maintenance of the instrument may only be carried out by trained personnel authorized by the operator of the facility. Personnel must read and understand this Operating Manual before carrying out its instructions. ...
  • Page 39: Appendix A: Technical Specification

    Page 39 APPENDIX A: TECHNICAL SPECIFICATION GENERAL Display Type High intensity reflective numeric and alphanumeric LCD, UV-resistant. Digits Seven 17mm (0.67") and eleven 8mm (0.31"). Various symbols and measuring units. Refresh rate User definable: 8 times/sec - 30 secs. Type ZB Transflective LCD with green LED backlight.
  • Page 40 Page 40 Sensor excitation Type PB / PC / PX 3.2V DC for pulse signals and 1.2V DC for coil pick-up. Note: This is not a real sensor supply. Only suitable for pulse sensors with a very low power consumption like coils (sine wave) and reed-switches. Type PD 1.2 - 3.2 - 8.2 - 12 and 24V DC - max.
  • Page 41 Page 41 Temperature Type TP 2 or 3 wire PT100. Standard range: -100°C to +200°C (-148°F to 392°F) - accuracy 0.1 °C (0.18°F). Update time four times a second. Note The linearity is internally compensated. Type ZV range: -200°C to +800°C (-328°F to 1832°F) - accuracy 0.5 °C (0.9°F). Type TA (0)4-20mA - with signal calibration feature at any current within the range.
  • Page 42 Page 42 OPERATIONAL Operator functions Displayed functions • compensated total and/or compensated flowrate. • compensated total and compensated accumulated total. • line temperature. • compensated total can be reset to zero by pressing the CLEAR-key twice. Total Digits 7 digits. Units L, m3, GAL, USGAL, KG, lb, bbl, no unit.
  • Page 43: Appendix B: Problem Solving

    Page 43 APPENDIX B: PROBLEM SOLVING In this appendix, several problems are included that can occur when the F126-P-EL is going to be installed or while it is in operation. Flowmeter does not generate pulses: Check:  Signal selection SETUP - 41, ...
  • Page 44: Appendix C: Communication Variables

    If we interpret this as a long integer value, it's value would be: 0x0000.0002.6CD0 = 158928. If this value needs to be calculated: 0*65536*65536 + 2*65536 + 27856 = 158928. For additional information regarding using your Fluidwell Modbus device, please read the ‘Fluidwell General Modbus Communication Protocol’ and ‘Modbus troubleshooting guide’ that are available through our website or your distributor.
  • Page 45 Page 45 SETUP VARIABLES OF THE F126-P-EL TOTAL REGs R/W TYPE VALUE / REMARKS unit uint8 0=none 2=m3 0x020 3=kg 4=lb 5=gal 6=usgal 7=bbl decimals uint8 0…3 0x021 K-factor uint32 1...9999999 0x022 Representation: 0.000010…9999999 depending on variable 54: decimals K-factor. decimals K-factor uint8 0…6 0x025...
  • Page 46 Page 46 FORMULA REGs R/W TYPE VALUE / REMARKS thermal expansion uint32 0…9999999 0x04A coefficient normal temperature uint16 0.00…99,999.99 0x219 step: 0.01 K Representation: temperature unit depending on variable 528 ANALOG OUTPUT REGs R/W TYPE VALUE / REMARKS analog output uint8 0=disable 1=enable 0x070...
  • Page 47: Index Of This Manual

    Page 47 INDEX OF THIS MANUAL accumulated Total keys actual settings low-battery analog Low-battery alarm floating output. main-function flowrate min. maintenance intrinsically safe output. model output loop powered. NAMUR-signal Analog output Operator level Backlight pass code 19, 43 battery life time 15, 38 power supply 25, 26...
  • Page 48 A3 serial number A4 pass code 0000 A5 tagnumber 0000000 Fluidwell bv HF126PEN_EL_TP_v0501_07 PO box 6 Voltaweg 23 Website: www.fluidwell.com 5460 AA Veghel 5466 AZ Veghel Find your nearest representative: www.fluidwell.com/representatives The Netherlands The Netherlands Copyright Fluidwell bv - 2014 - HF126PEN_EL_TP_v0501_07...