  • Page 1 Installation and User Guide GSM6H Kamstrup A/S · Industrivej 28, Stilling · DK-8660 Skanderborg · T: +45 89 93 10 00 · info@kamstrup.com · kamstrup.com...
  • Page 2: Table Of Contents

    GSM6H Description of GSM 6H GSM6H is a modem designed for the MULTICAL® 602, MULTICAL® 801 and the M-Bus master meters. After placing the modem in the module area, you will be able to communicate with /read the meter from a remote location. The module is a plug-and-play component that does not need any configuration when it is installed.
  • Page 3: Installation

    • Note that fire doors, concrete and metal plates disturb and weaken the GSM signal. • It is possible to order special directional antennas for areas with very poor signal conditions (please contact Kamstrup A/S for further information). 1.2 Start-up sequence 1 Immediately after start-up, all the Signal indicator diodes and the test diode switch on briefly (see Figure 5, page 12).
  • Page 4: Sim Card

    The unit can be ordered with the SIM card inserted from the factory. Please check that the card has been inserted. The telephone number of the card appears from a label on the unit. Note that Kamstrup A/S cannot be held responsible for theft and misuse of SIM cards from GSM 6H units.
  • Page 5: Signal Test

    3 The recommended signal strength is minimum 12. Note that when modems are installed in closed metal cabinets, the external antenna must be mounted outside the cabinet. Always check the signal strength by sending an SMS when the cabinet is closed. Kamstrup A/S • 5512687_C2_GB_09.2016...
  • Page 6: Diagram For Signal Conversion

    • The installation must not be handed over before the signal strength is 12 or more. • Always complete the installation by sending an SMS (=signal#) to control the signal strength when all doors and cabinets are closed. Kamstrup A/S • 5512687_C2_GB_09.2016...
  • Page 7: Antenna

    • Use only dual-band (900 MHz and 1800 MHz) GSM antennas. • Avoid placing the antenna right next to power cables, since it might disturb the signal. • If a long antenna cable is required, please contact Kamstrup A/S to obtain a “super low loss” antenna cable (order No. 6699460).
  • Page 8: Error Detection Help

    The signal strength is not good Mount an external antenna, which can be ordered at enough Kamstrup A/S (see chapter 5, page 7). The signal strength will not • Place the antenna in different places to find the location improve after mounting an with the best signal strength (see chapter 4, page 5).
  • Page 9: Sms Commands

    Syntax =READ_PRESSURE# Example 1 =READ_PRESSURE# Response, correct 2.34 bar, The following values are read: 2.23 bar, Pressure: [bar] Meter No.: 6349933 Meter number: Return response, meter error No meter response Return response, command error NO RESPONSE Kamstrup A/S • 5512687_C2_GB_09.2016...
  • Page 10: Gsm6H Variant Structure

    GSM6H 9 GSM6H Variant structure Top numbers Is ordered as a separate module for MULTICAL® 801 670XXXXX.801 Is ordered as a separate module for MULTICAL® 602 602XXXXX Is ordered as a separate module for M-Bus Master 670XXXXX.MBM – – Function MULTICAL®...
  • Page 11 GSM6H Figure 2 M-Bus Matser GSM6H module Connection of power supply External antenna Power supply Figure 3 MULTICAL® 801 Kamstrup A/S • 5512687_C2_GB_09.2016...
  • Page 12 GSM6H Figure 4 MULTICAL® 602 SIM card holder Connection for power supply GPRS diode Test diode Signal indicator Push button for alternative signal test Figure 5 Kamstrup A/S • 5512687_C2_GB_09.2016...