Advertisement

Quick Links

User Manual
Expert Net Control 2312
© 2019 GUDE Systems GmbH
Manual Ver. 1.1.1
valid from Firmware Ver. 1.00

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Expert Net Control 2312 and is the answer not in the manual?

Questions and answers

Summary of Contents for Gude Expert Net Control 2312

  • Page 1 User Manual Expert Net Control 2312 © 2019 GUDE Systems GmbH Manual Ver. 1.1.1 valid from Firmware Ver. 1.00...
  • Page 2 In particular, connected consumers can be switched remotely with Gude Control. "Gude Control" is available for the Expert Net Control 2312 series and can be free downloaded from the Google Play Store and iTunes Store.
  • Page 3: Table Of Contents

    Expert Net Control 2312 Table of contents Table of contents Chapter 1 Device Description Security Advice Content of Delivery Description Installation Stop Input Block Diagram Status LED Bootloader Mode Firmware-Update 1.10 Technical Specifications 1.11 Energy Measurement 1.12 Sensor Chapter 2 Operating...
  • Page 4 Expert Net Control 2312 Table of contents Syslog Email Chapter 5 Support Contact Declarations of conformity...
  • Page 5: Chapter 1 Device Description

    · Expert Net Control 2312 · CD-ROM and manual Description The Expert Net Control 2312 is a multipurpose device that is suitable for switching and monitoring of voltages. It has the following features: · Suitable for top hat rail mounting ·...
  • Page 6: Installation

    Expert Net Control 2312 Device Description · HTTP 1.1, E-Mail, DHCP, SNMPv1 (traps), SNMPv2c (traps), Syslog · Access protection via IP-access control · Access control with optional password · Controllable via iOS and Android App · Low own consumption · Compatible to products of brand Solar-Log ·...
  • Page 7: Stop Input

    Expert Net Control 2312 Device Description Start-up the device · Connect the device to an AC Adaptor (12V-24V AC or DC). · Plug the network cable into the Ethernet socket (RJ45). · Connect the neutral wire to the neutral wire connector (11).
  • Page 8: Block Diagram

    Expert Net Control 2312 Device Description Block Diagram block diagram for Expert Net Control 2312...
  • Page 9: Status Led

    Expert Net Control 2312 Device Description Status LED The Status LED shows different states of the device: · red: Device is not connected to the Ethernet · orange: Device is connected to the Ethernet, TCP/IP settings are not allocated · green: Device is connected to the Ethernet, TCP/IP settings allocated ·...
  • Page 10: Firmware-Update

    Expert Net Control 2312 Device Description · Remove and connect the power supply without operating a button by Software: · Start GBL_Conf.exe · Do a network search with the "Search" menu action · In menu "Program Device" activate the item "Enter Firmware"...
  • Page 11: Technical Specifications

    Expert Net Control 2312 Device Description 1.10 Technical Specifications Interfaces 1 x Ethernet port (RJ45) ENC 2312: 6 x screw terminal with 3 x relay make contacts (230V AC 16A) 2 x screw terminal for power supply 2 x screw terminal with 1 x stop input...
  • Page 12: Sensor

    Expert Net Control 2312 Device Description 1.12 Sensor An external sensor can be connected to the Expert Net Control 2312. The following sensors are currently available: Temperature-Sensor 7001 Cable length Connector Mini-DIN Measurement range -20°C to +80°C at ±2°C (maximum) and ±1°C (typical)
  • Page 13: Chapter 2 Operating

    Expert Net Control 2312 Operating Operating Operating the device directly The current status of the output is indicated by the color of the LED. Red indicates that the output is off, green shows that the output is on. On the device are the buttons "select" and "ok". If you press "select", the LED will blink for the first output, ie the output is selected.
  • Page 14: Using The Serial Interface

    Operating Optionally the device can be switched via a Perl script or external tools like wget. More information is available on our support wiki at www.gude.info/wiki. Using the Serial Interface There is a serial connection alternatively to the Ethernet port, where the power ports can be switched.
  • Page 15: Chapter 3 Configuration

    To view and change the network settings, you can use the program GBL_Conf.exe. The program is available for free on our website www.gude.info and is also available on the accompanying CD-ROM. You can also use GBL_Conf.exe to install firmware updates and trigger a reset to factory defaults.
  • Page 16 Expert Net Control 2312 Configuration Interface GBL_Conf To check the network settings with GBL_Conf.exe, start the program and choose "All Devices" in the "Search" menu. From the list select the appropriate device. The lower part of the left half of the win- dow now shows the current network settings of the device.
  • Page 17: Configuration Via Webinterface

    Expert Net Control 2312 Configuration Configuration via Webinterface Access the web interface: http://"IP-address" and log-in. Use the "Configuration" Tab to enter the configuration menu. Configuration - Output Ports 3.2.1...
  • Page 18: Configuration - Watchdog

    Expert Net Control 2312 Configuration Choose Output Port to configure: This field is used to select the output ports to be configured. Label: You can assign a name up to 15 characters for each of the output ports. Using the name, an identification of the the device connected to the port can be facilitated.
  • Page 19 Expert Net Control 2312 Configuration Enable watchdog: Enables the watchdog function for this Power Port. Watchdog action: When selecting reset, the Port will be turned off and switched on again after a Re- set Duration. The setting off leaves the Port in the off state.
  • Page 20: Configuration - Ip Address

    Expert Net Control 2312 Configuration the watchdog waits until the monitored device is answering to pings again. After this the watchdog is armed again. When you select the option retry BOOTING after RESET failure, the watchdog is armed directly after the watchdog action is executed.
  • Page 21: Configuration - Ip Acl

    Expert Net Control 2312 Configuration Use DHCP: Select "yes" if the TCP/IP settings should be obtained directly from the DHCP server: When the function is selected, each time the device powers up it is checked if a DHCP server is available on the network.
  • Page 22: Configuration - Http

    Expert Net Control 2312 Configuration Configuration - HTTP 3.2.5 HTTP port: Here can be set the port number of the internal HTTP. Possible values ? ? a re from 1 to 65534 (default: 80). If you do not use the default port, you must append the port number to the ad- dress with a colon to address the device from a web browser.
  • Page 23: Configuration - Sensors

    Expert Net Control 2312 Configuration Configuration - Sensors 3.2.6 Choose sensor port: Selects a type of sensor to configure it. The first digit "1" indicates the number of the sensor port (only important for devices with more than one sensor port). This is followed by the sensor name (eg 7002 for the hybrid sensor), a letter for the sub-type sensor and the changeable sensor name.
  • Page 24: Configuration - Snmp

    Expert Net Control 2312 Configuration Configuration - SNMP 3.2.7 SNMP-get: Enables the acceptance of SNMP-GET commands. Community public: The community password for SNMP GET requests. SNMP-set: Enables the acceptance of SNMP-SET commands. Community private: The community password for SNMP SET requests.
  • Page 25: Configuration - Syslog

    Expert Net Control 2312 Configuration Configuration - Syslog 3.2.8 Enable Syslog: Enables the usage of Syslog Messages. Syslog Server: If you have enabled Syslog Messages, enter the IP address of the server to which the syslog information should be transmitted.
  • Page 26: Chapter 4 Protocols

    Expert Net Control 2312 Configuration Recipient address: The e-mail address of the recipient. Enable authentification: Select this option if the e-mail server requires authentication. Username: User name that is registered with the SMTP e-mail server. Set new password: Enter the password for the login to the e-mail server.
  • Page 27: Syslog

    · Exceeding of max / min value of the measured power consumption Support You will find the latest product software on our website at www.gude.info available for download. If you have further questions about installation or operation of the unit, please contact our support team.
  • Page 28: Contact

    Expert Net Control 2312 Support Contact GUDE Systems GmbH Von-der-Wettern-Straße 23 51149 Cologne Germany Phone: +49-221-912 90 97 Fax: +49-221-912 90 98 E-Mail: mail@gude.info Internet: www.gude.info shop.gude.info Managing Director: Dr.-Ing. Michael Gude District Court: Köln, HRB-Nr. 17 7 84 WEEE-number: DE 58173350...
  • Page 29: Declarations Of Conformity

    Technische Dokumentation zur Beurteilung von Elektro- und Elektronikgeräten hinsichtlich EN 50581:2012 der Beschränkung gefährlicher Stoffe / Technical documentation for the assessment of electrical and electronic products with respect to the restriction of hazardous substances Köln, 29.9.2014 Dr. Michael Gude, Geschäftsführer / General manager, CEO...
  • Page 30 Expert Net Control 2312 © 2019 GUDE Systems GmbH 4/4/2019...

Table of Contents