INSTALLATION USER GUIDE CENTRAL VACUUM POWER UNITS FOR RESIDENTIAL USE ONLY 550VF1 / 650VF1 / 700VF1 AB0039 SFDB-DK, SFDB-DL SFDB-DM ODELS 1-877-896-1119 ENMAR ENTILATION VENMAR EGISTER YOUR PRODUCT ONLINE AT VENMAR 24009 rev. A...
GENERAL INFORMATION WALL INLET INSTALLATION TOOL LISTING MAKING THE WALL INLET CUTOUT The wall inlet should be located 18” on-center from the floor Depending on the installation, the use of the following tools and directly in line with the attic or basement inlet tubing hole may be required: previously drilled in the wall plate or header.
V800W CANSWEEP ® UNDER CABINET INSTALLATION Align the template (cut from this T e m instruction sheet) p l a onto the kick plate to the desired location, and trace the outline of the area. Cut out the desired opening and discretely mark the center of the...
V800W CANSWEEP UNDER CABINET INSTALLATION ( ® CONT Fig. A Fig. B Solvent weld a coupling to a piece of 2” central Friction fit the other end vacuum pipe, long enough of the coupling to the to reach the 4” x 4” access ®...
V800W CANSWEEP BASEBOARD WALL INSTALLATION ® Do not glue CanSweep ® the elbow. Choose a desired Make piping position on the baseboard connections as T e m between two studs. required and p l a Place the template (cut ready the short from this instruction sheet) 90°...
(e.g.: with door louvers). AD0078 CHANGING INTAKE LINE DIRECTION 550VF1 only: Put the 550VF1 ONLY APER RING bag back in place by grasping the edges of The intake line connects to the right side of the unit. However, its collar and insert it is possible to change this configuration;...
Hang power unit onto wall mounting bracket. Ensure the back brackets of the power unit are engaged with corresponding wall bracket fingers (or top fingers and lower tab for 550VF1 model; see figure below). Pull the power unit down to secure. 650VF1 AND 700VF1 18”...
POWER UNIT INSTALLATION GROUNDING INSTRUCTIONS CONT FITTING MAIN LINE TO POWER UNIT WARNING Improper connection of the equipment-grounding Run house vacuum line up to the elbow behind the power conductor can result in a risk of electric shock. unit. Insert the end of the line in the elbow opening and secure house vacuum line by hand tightening the screw Check with a qualified electrician or service person and nut provided (see illustration below) DO NOT GLUE.
Then, carefully remove it * Only 550VF1 unit is equipped with a disposable bag (391C). from the unit. AD0084 HOW TO EMPTY DEBRIS PAIL (650VF1 AND 700VF1 POWER UNITS ONLY) ...
This filter should be checked and cleaned This HEPA filter should be replaced every 5 years. Proceed as if necessary when replacement bag is installed (550VF1 follow: unit only), or when permanent filter is removed (650VF1 and ...
TROUBLESHOOTING GUIDE ROBLEMS OSSIBLE CAUSES OSSIBLE REMEDY 1. Loss or decrease of • Debris pail or disposable bag is completely full. • Change the disposable bag or empty debris pail suction occurs. as described on page 10. • Debris pail gasket damaged or missing. •...
ARTS AND EPAIRS In order to ensure your unit remains in good working condition, you must use Venmar Ventilation ULC genuine replacement parts only. Venmar Ventilation ULC genuine replacement parts are specially designed for each unit and are manufactured to comply with all the applicable certification standards and maintain a high standard of safety.
(3) years of the warranty for 550VF1 units, the first five (5) years of the warranty for 650VF1 units and the first six (6) years of the warranty for 700VF1 units. If in home service is not available, the product will be repaired or replaced, at Venmar Ventilation ULC’s discretion, by the nearest authorized service...