Magenta Research Infinea DVI Over Cat5 Quick Reference & Setup Manual

Advertisement

Quick Links

Infinea
DVI
Over Cat5/6

Quick Reference

&

Setup Guide

Magenta Research
Magenta Research
128 Litchfield Road, New Milford, CT 06776 USA
128 Litchfield Road, New Milford, CT 06776 USA
(860) 210-0546 FAX (860) 210-1758
(860) 210-0546 FAX (860) 210-1758
www.magenta-research.com
www.magenta-research.com
PN: 5310176-01, Rev 0, 12/06

Advertisement

loading

Summary of Contents for Magenta Research Infinea DVI Over Cat5

  • Page 1: Quick Reference

    Infinea Over Cat5/6 Quick Reference & Setup Guide Magenta Research Magenta Research 128 Litchfield Road, New Milford, CT 06776 USA 128 Litchfield Road, New Milford, CT 06776 USA (860) 210-0546 FAX (860) 210-1758 (860) 210-0546 FAX (860) 210-1758 www.magenta-research.com www.magenta-research.com...
  • Page 2: Table Of Contents

    MAGENTA INFINEA™ DVI UTP SERIES. Contents 1.Specifications Chapter Page Cable Required: Category 5, 5e, 6 shielded or unshielded twisted pair 1. Specifications....................2 Video Support: DVI-D VESA formats to UXGA (1600x1200 @ 60Hz) Introduction ........…............3 Maximum 2.1 Overview................…....3 Resolution and Refresh Rate: CAT5/5E: At 500 ft.
  • Page 3: Overview

    CHAPTER 2: Introduction MAGENTA INFINEA™ DVI UTP SERIES. 2. Introduction 3. Setup and Installation 2.1 Overview 3.1 Cabling Considerations Magenta’s Infinea™ DVI UTP Video series extends DVI-D signals over ordinary • We recommend mounting and connecting all cabling to the Infinea™ Series Category 5 or Category 6 cable.
  • Page 4: Link Status Led's

    Meaning Normal Operation == OFF ON == EXCEPTION—a serious problem has occurred with the unit. Contact Magenta Research. Normal Operation == ON ON == Active DVI signal detected from source for transmitter side or active DVI display detected if receiver side...
  • Page 5: Common Problems

    CHAPTER 4: Troubleshooting MAGENTA INFINEA™ DVI UTP SERIES. 4. Troubleshooting Appendix A. Cabling Pinouts 4.1 Common Problems In most cases, nearly every issue with the Infinea™ Series can be resolved by checking the CAT56 termination and making sure that it’s pinned to the 568B wiring specification. However, there may be other problems that cause the system to not perform as it’s designed.
  • Page 6: Appendix B. Configuration Jumpers

    APPENDIX B: Configuration Jumpers MAGENTA INFINEA™ DVI UTP SERIES. Appendix B. Configuration Jumpers The following diagram details configuration jumper settings for DVI display detection as well as how to set pixel or color compression modes. Jumpers that do not appear on this diagram are reserved and should not be changed.