16 - 64 outlets
LNB
Quattro
Power Supply
9934 (4 x SAT)
REF. 9933UK
or
9935 (4 x SAT + 1 Terr)
V
H
V
Low Band
TV
5 x 4 / 6 / 8 / 12 / 16
- 20 dB
Low Band
V
H
V
TV
V
H
V
Low Band
5 x 4 / 6 / 8 / 12 / 16
- 15 dB
Low Band
V
H
V
V
H
V
Low Band
5 x 4 / 6 / 8 / 12 / 16
- 10 dB
Low Band
V
H
V
V
H
V
Low Band
5 x 4 / 6 / 8 / 12 / 16
- 5 dB
UNITRON n.v., Frankrijklaan 27, B-8970 Poperinge, Belgium
TEL +32 57 33 33 63
FAX +32 57 33 45 24
www.johansson.be
E-mail : sales@johansson.be
Profiler Lite
45 dB
Amplifier
H
High Band
High Band
H
H
High Band
High Band
H
H
High Band
The power supply is connected to
whichever multiswitch and is used to feed
the LNBs and the amplifiers ref. 9934 / 9935.
Maximum delivered current is 2000 mA.
In order to avoid overload, check the total
High Band
H
consumption of the installation :
LNBs , ref. 9934 = 400 mA,
ref. 9935 = 500 mA ....
H
High Band
Connect the power supply to mains after
all coaxial cables have been connected.
Current is present on all 4 SAT trunk lines.
Each multiswitch and amplifier has a
LED power indicator.
Products are subject to change without notice. 02/06
Read carefully these instructions before connecting the unit.
The operating voltage is indicated on the nameplate of the housing.
To prevent fire, short circuit, shock hazard : Do not expose the unit to rain or moisture.
Install the unit in a dry location without infiltration or condensation of water.
Do not expose it to dripping or splashing.
Do not place objects filled with liquids, such as vases, on the apparatus.
If any liquid should accidentally fall into the cabinet, disconnect the power plug.
Refer to qualified technician before it's further operation.
To avoid any risk of overheating: Install the unit in a well aery location and keep a minimum
distance of 15 cm around the apparatus for sufficient ventilation.
The unit must not be exposed to any source of heat (sun, heater,...).
Do not place any naked flame sources, such as lighted candles, on the apparatus.
Do not install the product in a dusty place. Pull out power plug to make the different
connections of cables.
To avoid electrical shock, do not open the housing.
Cleaning :
Only use a dry soft cloth to clean the cabinet.
Do not use solvent.
Servicing :
For repairing and servicing refer to qualified personnel.
R
R
REF. : 9933UK
Power Supply 15V / 2.0 A
Instruction Manual
Technical specifications
- AC input :
240 V~ / 50 Hz
- DC output :
15 V
- Max. output current :
2.0 A
- Connector :
Jack Ø2.1 female
- Power :
50 VA
- Security :
Short circuit protected
Double isolated
- Operating temperature range :
-5° to +50° C
- Dimensions :
176 x 71 x 47 mm.
Safety instructions