Download Print this page

Philips VL72 Installation Instructions page 2

Advertisement

Philips Lighting Company
200 Franklin Square Drive
Somerset, NJ 08873
Phone (US): 855-486-2216
Phone (CAN): 800-668-9008
SAFETY WARNING:
ALWAYS TURN FIXTURE OFF/DISCONNECT POWER AND ALLOW
TO COOL BEFORE PERFORMING ANY MAINTENANCE
TOOLS REQUIRED:
-1/2" Socket/Driver
-5/32" Allen Wrench/Driver
-Philips Head Screw Driver
INSTALLATION:
1) TURN POWER OFF.
2) Loosen, but do not remove (4) globe fasteners on pod.
3) Lift globe from fixture.
4) Remove existing ballast assembly.
- Push spring clip to release ballast module, twist ballast
module counter-clockwise, and lift to remove.
- Disconnect blue power quick disconnect.
5) Remove ballast assembly ring by removing existing screws.
6) Remove terminal block and bracket (if applicable)
7) Assemble Ecoswap to camden adapter by twisting
clockwise until spring clip snaps into place.
8) Make proper wiring connections.
NOTE: In many cases, you may need to remove existing
blue power disconnect to "bug" wires.
9) Install entire unit onto fixture with (2) 1/4-20 screws while
ensuring wires are not being pinched.
NOTE: For Type 3 distribution modules, rotate to orient
"Street Side (SS)" identification located on
Ecoswap, toward street.
10) Carefully lower globe onto fixture.
11) Tighten (4) globe fasteners to secure globe.
REFERENCE: Please see enclosed Power Selection drawing
to adjust wattage output of Ecoswap module.
INSTALLATION INSTRUCTIONS:
V71 & V72
ECOSWAP ASSY
1/4-20 SCREWS
CAMDEN ADAPTER
LOOSEN FASTENERS
TO REMOVE GLOBE
(EXISTING)
(EXISTING)
(Retrofit)
(NEW)
(NEW)
(NEW)
POD
32002016, revision A