  • Page 1 www. d a k a c o r p . c o m B u r n W i s e Y o u r Gu i d e T o B e s t B u r n i n g P r a c t i c e s 5 / 1 / 1 5 P a g e 1 o f 4...
  • Page 3 K e e p a l l f l a mma b l e h o u s e h o l d i t e ms - d r a p e s , f u r n i t u r e , b o o k s , e t c . - f a r a w a y f r o m t h e a p p l i a n c e .
  • Page 4 R e f e r t o y o u r o w n e r ’ s ma n u a l f o r i n s t a l l a t i o n g u i d e l i n e s a n d o p e r a t i n g i n s t r u c t i o n s . S t a r t a s ma l l f i r e w i t h d r y k i n d l i n g t h e n a d d a f e w p i e c e s o f w o o d a t a t i me .
  • Page 5: Principle Of Operation

    SUPPLEMENTARY / CENTRAL WOODBURNING FURNACE MODEL 832 DAKA Corporation • 955 Industrial St NE • Pine City, Minnesota • 55063 Phone (320) 629-6737 • Fax (320) 629-3677 • www.dakacorp.com INSTALLATION AND OPERATION INSTRUCTION MANUAL NOTE: These models have been tested and listed in accordance with Underwriters Laboratories standard UL 391-2010-March 2010 and Sept.
  • Page 6 .06" water column updraft (DAKA barometric regulator #283 with adjustable settings available at extra cost through your DAKA dealer or online @ www.dakacorp.com / Energy Division or by calling Toll-free 1-800-884-3252).
  • Page 7: Installation Instructions

    - Open box and remove individual firebricks and blower first. - Check piece count against parts list in back of manual. PLEASE DO NOT RETURN THE PRODUCT TO THE STORE WHERE PURCHASED. daka 832 furnace manual_3-18-13 Page 3 of 14 September 26, 2012, Revised March 18, 2013...
  • Page 8: Furnace Assembly

    Attach 90° connector to junction box on the blower motors and straight connector end into one knockout hole on side mounted junction box ring. daka 832 furnace manual_3-18-13 Page 4 of 14 September 26, 2012, Revised March 18, 2013...
  • Page 9: Wiring Instructions

    Attach a 90° sheet metal elbow to one end of a straight 10" pipe of a length sufficient to project out over the DAKA furnace; insert this 90° elbow into supply plenum of primary furnace with outlet pointing upward. Slip plenum collar over straight end of 10" pipe and push up tight against supply plenum for a good air seal.
  • Page 10: Operating Controls

    Snap Disc Fan Control (Marked F120 or F110) The snap disc fan control (mounted in the J-box extension ring on the side of the DAKA furnace) is designed to turn on the multi-speed blower on the DAKA furnace whenever the air temperature within the air jacket exceeds 120°F and turn it off whenever the air jacket temperature falls below 100°F.
  • Page 11 CAUTION! Do not expect the DAKA furnace to keep the house as warm during a power failure as when power is on. Do not attempt to increase heat output by opening ash door or fire door.
  • Page 12: Troubleshooting

    2. Auto Damper setting too low. Customer Service DAKA CORPORATION 955 Industrial St NE Pine City MN 55063 320-629-6737 Monday through Friday, 8 AM to 4:30 PM Central Time daka 832 furnace manual_3-18-13 Page 8 of 14 September 26, 2012, Revised March 18, 2013...
  • Page 13 N - COLD AIR RETURN GRILL O - COLD AIR PLENUM P - WARM AIR PLENUM Q - DUCT END CAP R - COLD AIR RETURN DUCT daka 832 furnace manual_3-18-13 Page 9 of 14 September 26, 2012, Revised March 18, 2013...
  • Page 14 From Horizontal Ducts beyond 6 Ft. of Plenum – 0” FIG. 4 – Clearances to Combustibles FIG. 5 – Alternative Warm Air Plenum Pipe Insert Designs daka 832 furnace manual_3-18-13 Page 10 of 14 September 26, 2012, Revised March 18, 2013...
  • Page 15 2 blue wires coming down from the fan control located on the side of DAKA furnace. Install 90° conduit connector on end of flex conduit. Insert the 2 blue wires through hole in top of filter box cover. Place conduit connector nut over blue wires.
  • Page 16 FIG. 7 – Wiring Schematic daka 832 furnace manual_3-18-13 Page 12 of 14 September 26, 2012, Revised March 18, 2013...
  • Page 17 PARTS LIST – DAKA MODEL 832 FURNACE Also refer to #218 Instruction Manual for other parts Part Description Part Quantity Fire Door w/gasket 34200 Junction Box Ring - 4x4 62630601 Transformer/Relay 58640002 Blower Bracket 63611002 1 pr Ash Door Assembly...
  • Page 18: Limited Warranty

    DAKA will repair or replace defective components, at our option, at no charge for parts and labor, and will pay freight charge for one-way shipment for warranty claims during first year.