Bio 200D Instructions Manual

Ultrasonic convex-scanner

Advertisement

Quick Links

Ultrasonic
Convex-Scanner
INSTRUCTIONS
Note:
Customers are requested to read the manual in detail before using the equipment and to adhere
strictly to the attention of the matters, properly custody if necessary, to refer for further guidance.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 200D and is the answer not in the manual?

Questions and answers

Summary of Contents for Bio 200D

  • Page 1 Ultrasonic Convex-Scanner INSTRUCTIONS Note: Customers are requested to read the manual in detail before using the equipment and to adhere strictly to the attention of the matters, properly custody if necessary, to refer for further guidance.
  • Page 2 Dear Customer, Thanks for purchasing this ultrasonic scanner. Before use , please read the manual carefully and follow the instructions contained here. Please keep the manual for future reference. Follow these steps before your operation of the apparatus: 1. Make sure that the existing configuration of the apparatus is consistent with the packing list.
  • Page 3 Thanks for choosing the enhanced electronic convex-array ultrasonic diagnostic apparatus .In order to ensure this machine to work safely and properly, read the specific content in the user’s guide, which includes the apparatus features, operation method, operation user’s guideline, maintenance, packaging, storage, transportation etc.
  • Page 4: Table Of Contents

    CONTENTS 1 INTRODUCTION 2 TECHNICAL SPECIFICATIONS 3 ENVIRONMENTAL REQUIREMENT 4 APPARATUS SETTING UP 5 FUNCTION OF KEYBOARD 6 OPERATION 7 OPTIONAL ACCESSORIES 8 MAINTENANCE 9 TRANSPORTATION AND STORAGE 10 TROUBLE SHOOTING 11 MANUFACTURER'S COMMENTS 12 SERVICE GUIDELINES APPENDIX1...
  • Page 5: Introduction

    1. Introduction 1.1 Features With the advance of VLSI and SMT, the apparatus is more reliable compared with other products. By adopting multistage dynamic focalizing, variable aperture, digital scanning, related digital graphic processing, etc., the apparatus can provide sensitive, steady, clear, high-resolution pictures.
  • Page 6 1.3 CAUTION FOR THOSE WOMEN AT THEIR EARLY PERIOD OF PREGNANCY, LONG TIME OF IRRADIATION IS NOT SUITABLE. 1.4 Safety Standards Design and production strictly conform to GB10152-1997 B-Type Ultrasonic Diagnose Apparatus and enterprise standard Electronic Linear Array/Convex Array Ⅰ Type B Ultrasonic Diagnose Apparatus.
  • Page 7 1.5 Principle block diagram of product. ZOOM PROB PROCESS M MODE TRANSM CONT IN PHASE VIDEO B MODE CRYST IMAGE GRAY WRITE/R MOUSE KEYBOARD MONITOR POWER...
  • Page 8: Technical Specifications

    2. Technical Specifications 2.1 Functions and Specification...
  • Page 9 3.5MHz Electronical Convex Scanning (R=60) (2.0M---5.0M F.C.) Main Probe 6.5MHz Electronical Convex Scanning (R=13) (5.0M---8.0M F.C.) Optional Probe 7.5MHz Electronical Lining Scanning (Fleet Surface) (5.0M---10.0M F.C) Max.DisplayDepth(mm) ≥240 Distinguish Oriental ≤3(Depth≤80mm) ≤4(80mm< Depth ≤130mm) Rate Portrait ≤2( Depth ≤80mm) ≤3(80mm< Depth ≤130mm) (mm)...
  • Page 10: Environmental Requirement

    2.2 Power of Ultrasonic Output SEE APPENDIX 1 3. Environmental Requirement 3.1 Operation Environmental Requirement Environmental tests of the apparatus conform to the requirements of climatic environmental test group and mechanical environmental test group Ⅱ in GB/T14710-93 Environmental Requirements and Testing Methods of Medical Electric Apparatus. Ambient Temperature: +41℉~+104℉...
  • Page 11: Apparatus Setting Up

    4. Apparatus Setting up 4.1 Unpacking Check At the time of unpacking, please pay attention to the instructions on the packing box. After unpacking, check the apparatus and count accessories and documents supplied with the apparatus (stated in the following table) according to the packing list. 4.2 Setting up After setting up the apparatus, let us show you around the machine.
  • Page 12: Function Of Keyboard

    4.2.1 Power Check Please check the power supply condition and ensure that the electricity supply conform to the required standard. Electric power socket in the apparatus operating room shall be standard tri-hole power socket, grounding terminal should connect with the grounding conductor of the grounding field in the power protection system.
  • Page 13 could be displayed contineously. :Numeric keys. For setting the clock, date, patient’s number, age, —— measurements, etc. :Direction keys. Press these keys for moving the cursor in the mode of measurement. Or moving the windows when zooming partially. In the mode of B/M, press them for moving the sample lines right or left;...
  • Page 14 Press this key to start the cinema function. Cine For the selection of the focus. Focs In B,B/B mode,the apparatus offers 4 periods adjustable focuses.By the combination of the focuses, the much more clear images could be obtained.The current combination of the focuses appear on the right of the screen.Press this key,“Foc”is highlighted,and it is possible to adjust the combination of the focuses.
  • Page 15 1. UP--DOWN 2. LEFT--RIGHT 3. BLACK—WHITE 4. Per: 5. γ:1 6. EXIT “1.UP—DOWN” indicates to overturn the image up and down. “2.LEFT—RIGHT” means to turn the image to left or right. “3. BLACK—WHITE” indicates the shift of the image from white to black. “4. Per” means the frame selection which is divided into 4 grades.
  • Page 16 1. BPD-FW 2. CRL 3. GS 4. FL-FW 5. HC-FW 6. AC-FW 7. EDD 8. AFI 9. EXIT "1.BDP-FW" for the biparietal diameter fetal weight; "2. CRL" for the first long arm; " 3. GS" for the pregnancy sac; " 4. FL-FW" for the long femur fetal weight; " 5. HC - FW "for the re-fetal head circumference;"...
  • Page 17 Key to shift from the capital letter to small letter. Cap./Sm Indicator key It is used to indicate the diagnosing parts or the pathological changes. In the mode of body mark notes, press this key and you can have different directions of the indicator, and it is movable in the area of the body mark which shows the diagnosing part.
  • Page 18: Operation

    6. Operation 6.1 Switching on First, turn on the magnetic lock on the front panel of apparatus, then press down the Power button, which will light the power-indicate LED on the keyboard. When apparatus runs into normal working state, you can use brightness, contrast, gain and near-restrain buttons to get required image.
  • Page 19 of the screen. (Unit: cm) When measurement is over, repeat the third step to conduct multiple measurement. Three sets of results will be shown on the bottom of the screen. (Unit: cm) Measurement of perimeter and area Press the “Measurement” key to activate the prompt menu of measurement; press the key 2 to select the “2.Area”...
  • Page 20 How to use the contrail ball (route ball mouse) Click the “L” key to activate the first indicator “+”,move this “+”to the initial point of the measurement; click the “R” key of the ball to mark the beginning point of the measurement and at the same time to activate the second indicator “+”(Note: click the “L”...
  • Page 21 1. Press the Left key and an indicator appears. Move the indicator to any positon, press the Middle key to get another indicator. The Shift key may be used to exchange the moving indicators. Turn the ball to revise the long pathway and the circumrotating direction.
  • Page 22 measurements as you like. 4. To escape from the measurement, press the Middle key or any key in the mode of notes. Measurement of Heart Rate This measurement is available only in the B/M mode and M mode: Just like the measurement of distance, and there will be 3 varied groups of figures appearing on the screen with the moving of the indicator.
  • Page 23 3. Store the images by orders: i) in the order of numbers: press “1”, the apparatus starts to store the picture, and on the screen, it shows “Please wait 20 S…”.In 2o seconds, the first image has been stored permanently. If you want to continue the storage of other pictures, press the Freeze key first, then follow the steps mentioned above and you can store the rest pictures easily.
  • Page 24 Calculation of the obstetric table 1) Press the “Obstetric table” to activate the soft menu of the obstetric table ,of which: 1. BDP-FW for the biparietal diameter; 2. CRL for the first long arm; 3. GS for the pregnancy sac; 4.
  • Page 25 measured region, and then were measured from the measurement of the Closed curves and the fraction of the long axis of value, can obtain the head circumference or abdominal circumference value. 3) How to calculate the estimated date of birth: Select “...
  • Page 26 The function of Notes Press the Note key to activate the notes menu: By selecting the numbers, 1. ID: to input the patient’s recorder number,maximum 6 characters. 2. SEX: to select the gender of the patient,O stands for male,1 for female. 3.
  • Page 27 USB function ( Optional ) Insert the USB, when the indicator light is flashing,press the key to see a window on the screen: USB WRITE USB READ EXIT 1、“USB WRITE” to store the images;2、“USB READ” to read only the images from USB;3、“EXIT”.
  • Page 28: Optional Accessories

    long time, disconnect the power plug from the socket. Caution: Do not un-plug the power cable when the apparatus is still working. Wait for 2-3 minutes to re-start the apparatus after shutting it down in order to protect the apparatus from being damaged. 7.Optional Accessories The apparatus is equipped with a 3.5MHz electronic convex scanner probe.
  • Page 29 cotton ball containing alcohol. When the interior part needs to be cleaned, use the fan to tidy the dust. Do not turn on or turn off the apparatus frequently, Wait for 1-2 minutes to re-start up the apparatus after shut down in order to protect the apparatus from being damaged.
  • Page 30: Transportation And Storage

    When the probe is soaked into liquid, the distance above the sound window should be more than 10mm; otherwise, the interior components would be damaged by the liquid which seeps into the probe. Check the exterior of probe regularly to ensure that the outer layer of the probe is fully closed.
  • Page 31: Troubleshooting

    the packages directly on the ground, quite close to the wall, or the ceiling. 10. Troubleshooting There might be some troubles occurred during the operation. Since these kinds of trouble may have negative influence on user’s working procedure, we provide you with some ways to avoid them. If the trouble still exists, call the technician for help, or contact the sales reps.
  • Page 32 10.2 Troubleshooting SYMPTOM CORRECTIVE ACTION When the power switch is 1. Check the power. turned on, power indicator 2. Check power cable and its plug. isn’t on, and there is no 3. Make sure the fuse (fuse tube) isn’t broken picture showed on the screen.
  • Page 33: Manufacturer's Comments

    11. Manufacturer’s Comments Products of our company are manufactured strictly under the national standards—GB 10152-1997 about “B-type Ultrasonic Diagnostic Device” and GB 9706.1-1995 about “Medical Electrical Device section 1: Requirements for Safe Operation”. All the relevant specifications are accordant with the national standards. Our product will be under the terms of 3-guarantee for the domestic sales, they are: 1.
  • Page 34: Service Guidelines

    12. Service Guidelines If there is any trouble, please try the following steps: Refer to Section 10 for the simple trouble-shooting. Make sure that connection between the different parts is correct. You might solve the problem by yourself at first. Call the local dealer and engineer for further help.
  • Page 35: Appendix1

    Appendix 1. Sonic Output Power: Testing Mode:B Mode Testing Desc. Standards and Application No. Test result Comment Remark Max. Power The average sonic output power in the max. space. -------- 91.5 (mW) GB16846-1997 4.2.2a) Peak Value Sonic Pressure, -) -------- P-(MPa) 2.54 GB16846-1997 4.2.2b)
  • Page 36 Inspection state: M mode Remark Description Standards Results Comments Max. Power The max. average output power. -------- 39.1 (mW) GB16846-1997 4.2.2a) Peak value minus sound pressure -------- P-(MPa) 2.88 GB16846-1997 4.2.2b) -------- Sound strength of the output wave Iab(mW/cm 13.92 GB16846-1997 4.2.2c) The average sound strength of the peak value.

Table of Contents