Servicing Procedure - CALOR Provence Safety And Maintenance

Table of Contents

Advertisement

S S e e r r v v i i c c i i n n g g P P r r o o c c e e d d u u r r e e – – T T o o b b e e p p e e r r f f o o r r m m e e d d b b y y a a q q u u a a l l i i f f i i e e d d g g a a s s t t e e c c h h n n i i c c i i a a n n
1) Perform full clean as detailed on page 4
2) Perform leak test on control valve and all gas joints from regulator to main burner and ODS.
3) Ignite unit and ensure flame picture is correct, see below
A flame picture as shown on i i m m a a g g e e 2 2 o o n n p p a a g g e e 2 2 indicates
incomplete combustion.
Repeat cleaning of the main burner and primary air inlet.
Check regulator pressure to ensure correct pressure is
being supplied 28-30mbar.
4) Ensure heater is being used in a room no smaller that
64 cubic metres and with permanent ventilation directly
from the outside into the room of 80cm squared area.