Advertisement

INFRARED HEATER
Model CH24A7R
The photo is only for a reference, maybe it will be a light different with the actual device.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the CH24A7R and is the answer not in the manual?

Questions and answers

Summary of Contents for Stealth CH24A7R

  • Page 1 INFRARED HEATER Model CH24A7R The photo is only for a reference, maybe it will be a light different with the actual device.
  • Page 2: What's In The Box

    IMPORTANT INFORMATION Please carefully read the Operation Manual before using the infrared heater. This Operation Manual contains the important information on your safety, as well as some recommendations on proper use of the appliance and its maintenance. WHAT’S IN THE BOX Ø Heater fitted with flexible cord and plug. Ø Operating and Installation Instructions. Ø One small box contains 2 sets of Brackets. Ø One remote controller SAFETY INSTRUCTIONS Ø During use of the infrared heater, it is necessary to observe some precautions. Improper operation with disregard of precautions may result in infliction of harm to health of the user and other people, as well as in infliction of damage to their property. Ø Use only the voltage specified on the rating plate of the heater. Ø ONLY connect the appliance to a properly installed socket-outlet with earth contact. Ø The heater should be connected to the electric mains equipped with an automatic circuit breaker. Ø The unit must be handled with care, and avoid vibration or hitting. Ø WARNING: FIRE RISK EXISTS IF THE HEATER IS COVERED BY OR POSITIONED CLOSE TO CURTAINS OR OTHER COMBUSTIBLE MATERIALS.
  • Page 3: How To Operate The Heater

    the heater. Ø The installation must be equipped with a standard electrical power point with a break contact distance of at least 3mm. The standard power point must be installed by a licensed electrician. Ø If the heater is to be mounted on an incline (eg. Sloping or angled ceiling), ensure the electrical connection is located at that lowest point of the heater. Ø Do not connect the appliance to the mains source until it has been installed in its final location and adjusted to the position it will be used in. Ø Do not operate with the cord coiled up as this could cause a buildup of heat, which could pose a hazard. Ø The use of an extension cord with this appliance is not recommended. Ø Do not allow cord to come in contact with heated surfaces during operation. Ø Do not run cord under carpeting, throw rugs or runners etc. Arrange cord away from areas where it is likely to be tripped over. Ø This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety.
  • Page 4: Operation

    Infrared heaters are designed for general, additional, and local heating of residential, industrial, production, utility, and similar areas, such as institutions, public catering areas, storage facilities, hangars, agricultural facilities, of which high ceilings and open areas need to be heated. Technical Specification MODEL NAME CH24A7R Voltage 240V~ 50Hz Rated power (W) 2400 Ideal Mounting height 1.8- 2.1...
  • Page 5 NOTE: Discoloration of paint on the heater body wall directed to the ceiling during operation is not a defect. Changing of color ü for heating plates is not defect. After switching on the appliance for the first time and following extended periods on non-use, the appliance may expel ü a slight odor for a short time. It will not affect the use of the heater. To exclude unpleasant burnt odor, it is recommended to keep the heater clean preventing accumulation of dust on it ü The distance between the heater and the remote control should be less than 3 metre, and the remote control must be ü directly point to the receiver on the front panel during the operation. 4 Lamps of timer ,will be in 1 Lamp of heating status In Red: High power setting; White color when the timer is activated. The number below In Green: Medium power setting In Blue: Low power setting the setting of the timer. Receiver: Receiving signal sending from the Remote control Operations: 1.
  • Page 6 2. Point the remote control directly to the receiver, press the button of “ON”, the device will sound 1 beep and the lamp of heating mode turn in red, the device starts to heat in high power mode (100% the rated power) Press the button of “OFF” again, the device will sound 1 beep the lamp of heating status turns in blue and twinkle, the device stop heat and will in stand-by mode. 3. When the device is in heating mode or in stand-by mode, Point the remote control directly to the receiver and press the button “low”, the device will sound 1 beep, and starts to heat in lower power mode (33% of the rated power). The lamp of heating status turns in BLUE color. 4. When the device is in heating mode or in stand-by mode, Point the remote control directly to the receiver and press the button of “Med”, the device will sound 1 beep, and starts work in middle power mode (66% of the total rated power). The lamp of heating mode turns in the Green color. 5. When the device is in heating mode or in stand-by mode, Point the remote control directly to the receiver and press the button “High”, the device will sound 1 beep, and starts work in high power mode (100% of the total rated power). The Lamp of heating mode turns in Red color.
  • Page 7: Installation

    Press the button “1” and “2” separately, the delay off timer can be set in 3 hours as below. Accordingly, the maximum timer can be set in 13 hours by press the key 1+2+4+6=13 hours separately as below. INSTALLATION Before installation, read the manual carefully. The heater must be installed in accordance with the manufacturer’s installation instructions This heater comes with a pair of stainless steel adjustable angle mounting brackets. The adjustable angle enables the heater to be installed on vertical, horizontal and inclined surfaces. The ideal mounting position is directly above the area to be heated with a longitudinal orientation and facing vertically downwards. If this is not possible, the heater(s) can be mounted on a wall and angled downwards.
  • Page 8 Warning: The heater must never be installed in the upwards or inwards facing position, the heating surface must always be positioned to direct the heat in a downwards or outwards direction. Clearances Minimum clearances when mounting the heater on A VERTICAL WALL Minimum clearances when mounting the heater parallel with a ceiling. Minimum clearances when mounting the heater at an angle to the ceiling.
  • Page 9 Installation Process WARNING! Mounting of the infrared heater and its connection to the electric mains should be carried out only by qualified specialists according to the Electrical Installation Regulations and Power System Safety Standards 1. Open the factory package and carefully take the heater out. 2. Take out the packing paper sheet from the end of heater 3. Take out one pair of mounting Brackets. These adjustable brackets allow direct ceiling or wall mount, and come with preset angle options of parallel, 15°, 30°, 45° and height 170mm. 4. T he correct installation process, as per the diagram above, select the heater location on the ceiling by locating the stud or structural beams to ensure secure fastening of the heater, whilst observing the minimum clearances from the floor and other objections. 5. Install two brackets on the ceiling or wall with the following minimum recommended bracket distance “B”. Model No “B” MINIMUM DISTANCE (mm) CH24A7R 990 ±50...
  • Page 10 6. Set the adjustable angle mounting brackets to desired angle and fasten brackets by spanner For ceiling mounted installation, the available mount angles are restricted to 0°, 15° and 30° only. For wall mounted installation, the available mount angles are restricted to 15°, 30° and 45° only. 7. Hang the heater on the brackets and firmly secure in place with the mounting bracket locking plates by tightening bolts. labelled NOTE: Depending on material and design of ceiling structural elements, the heater must be secured with the correct fasteners. ü The weight of the heater is up to 5.3Kg, the installation location must be able to hold 5 times the weight of the heater. Connection to electric mains • The heater is designed for connection to the single-phase 240V~ 50HZ electric mains equipped with a earth. • Before connection, make sure that specifications of the electric mains at the connection point meet the single-phase 240V~ 50Hz voltage. • The heater must not be located immediately below a power point. Power point should not be located at the back of the...
  • Page 11: Maintenance

    heater. The power point needs to be located outside the physical footprint of the heater to minimize heat build-up behind the heater. • If the heater is to be mounted on an incline (eg. Vaulted ceiling), ensure the power point located at that lowest point of the heater. MAINTENANCE • A ny maintenance should only be carried out by a qualified electrician. • D uring operation, it is necessary to periodically (once a year) check the electric cable contacts and terminal connectors for good tightening. • I f the body becomes dirty, wipe off dust with a towel, and the radiating boards should be wiped in cold condition with a damp soft rag. WARMING! Never immerse the appliance in water! Danger to life! ü TROUBLESHOOTING Possible malfunctions are given in Table below. SYMPTOM CAUSE Will not heat / No operation indicator Check that power is connected and switched on Heater smells when first used. This is caused by oil or dust left over from the manufacturing process and will stop after a short time Faint smell for short periods after turning This is normal and should stop after a short time on the heater Heater smells when turned on after Build-up of debris and dust on the heater, Switch the heater off and periods of no use allow it to cool down and then clean Clinking noises when heater is turned on This is expansion and contraction noises of the heaters metal and after being turned off components and is normal Poor heating performance Exposure to extreme ambient conditions such as high winds / excessively cold temperatures can lower the heating performance of an outdoor installation...
  • Page 12: Wiring Schematic Diagram

    SYMPTOM CAUSE There is a burning smell and or strange Turn off the heater, and contact seller. sounds (other than normal expansion and contraction noises) coming from the unit When associated circuit breaker (safety, Turn off the heater, and contact your authorized electrical installer ground) is thrown or a fuse is blown Poor heating performance Incorrectly sized installation, contact your authorized electrical installer Faulty heater element, turn off the heater, and contact seller Will not heat / No operation indicator Check that power is connected and switched on, if still faulty, turn off the heater, and contact seller or your installing electrician. WIRING SCHEMATIC DIAGRAM WARRANTY INFORMATION. The STEALTH is covered by a 12 month from date of purchase “Return to Base” Warranty. It is the owners responsibility to return the Heater to RPM Group Limited Service Center with a copy of the purchase receipt The warranty covers manufacturing defects/failures. It does not cover damage caused by misuse or damage caused by incorrect installation. RPM Group Service Centre : 296 Trig Road, Whitford, Auckland . We recommend Fastway Couriers as they have 24/7 access to the service center. For questions or queries call the RPM Group on 0800 394772.

Table of Contents