Marking concept for hazards and hints ................3 Responsibilities of the operator..................3 Applications ..........................5 Product features ......................5 2.1.1 Basic features and benefits of Campetto 7: ............5 Scope of delivery ......................5 Technical information ...................... 5 Introduction ..........................6 Installation conditions Campetto 7 Underfloor distributor system ........
Campetto 7 Underfloor distributor system 1 General information 1.1 Marking concept for hazards and hints Hazard Hazardous situation which will cause serious injury or even death if it is not prevented. Caution Hazardous situation which could cause slight to moderate injury if it is not prevented.
Page 4
Campetto 7 Underfloor distributor system The installer has to provide the user with all information relating to the operation of the system. Make sure that underfloor distribution systems which can only be operated when they are in open mode, do not provoke any security risk during the operation (risk of unwanted closure of lid, manipu- lation, e.g.).
GIFAS hard rubber distributor box using a flexible cable the Campetto cover is available in different load capacities (standard B125, special versions up to...
Hint Read all instructions before starting installation. Our sales department will be happy to answer any questions you may have. 3.1 Installation conditions Campetto 7 Underfloor distributor system 3.1.1 Work to be done on site by customer The cover system is not sealed against surface water; this means that the customer must provide for the drainage of the underfloor distributor system.
The electrical connection may only be made by trained personnel and is the responsibility of the operator. 3.2.1 Principle drawing The details necessary for proper installation can be found on the project-specific drawing from GIFAS. Custom models may vary from the following drawings. Created...
The cover opens automatically through the use of gas springs. They support muscular force and allow for the controlled opening and closing of the cover. 3.3 Example installation Campetto 7 (with reservoir cover) Insert concrete pipe and ensure drainage Feed electrical supply cord through concrete pipe...
Campetto 7 Underfloor distributor system Use the levelling bolts to precisely align the Underfloor distribution system with the surface Cleanly fill in underneath the Underfloor distribution sys- tem to prevent subsidence Fill the reservoir cover 3.4 Storage No additional measures are required for storage. With regard to packaging, pay attention to protection against damage.
CH-9424 Rheineck www.gifas.ch Technische Änderungen und Irrtümer vorbehalten. Dieses Dokument ist Eigentum der GIFAS-ELECTRIC GmbH und darf ohne vorherige schriftliche Genehmi- gung durch GIFAS-ELECTRIC GmbH weder ganz noch in Auszügen kopiert, übersetzt, übertragen, dupliziert oder an Dritte weitergegeben werden. Created...